Preliminary study on the application of the heat pipe to the passive decay heat removal system of the modular HTR

被引:11
|
作者
Ohashi, K [1 ]
Hayakawa, H
Yamada, M
Hayashi, T
Ishii, T
机构
[1] Fuji Elect Co Ltd, Nucl Power Promot Div, Chiyoda Ku, Tokyo, Japan
[2] Tokai Univ, Dept Nucl Engn, Hiratsuka, Kanagawa 25912, Japan
关键词
D O I
10.1016/S0149-1970(97)00047-4
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
To investigate the applicability of heat pipe to the decay hat removal (DHR) system of the modular HTRs, preliminary study of the Heat Pipe DHR System was performed. The results show that the Heat Pipe DHR System is applicable to the modular HTRs and its heat removal capability is sufficient. Especially, by applying the variable conductance heat pipe, possibility of a fully passive DHR system with lower heat loss during normal operation is suggested. The experiments to obtain the fundamental characteristics data of the variable conductance heat pipe were carried out and the experimental results are also shown. (C) 1997 Published by Elsevier Science Ltd.
引用
收藏
页码:587 / 594
页数:8
相关论文
共 50 条
  • [1] Preliminary study on the application of the heat pipe to the passive decay heat removal system of the modular HTR
    Fuji Electric Co, Ltd, Tokyo, Japan
    Prog Nucl Energy, 3-4 (587-594):
  • [2] The study of passive cooling system assisted with separate heat pipe for decay heat removal in spent fuel pool
    Lai, Kun
    Wang, Wen
    Yi, Chongchong
    Kuang, Yiwu
    Ye, Cheng
    ANNALS OF NUCLEAR ENERGY, 2018, 111 : 523 - 535
  • [3] Preliminary design and experimental study of heat transfer characteristics of a passive residual heat removal system for a heat pipe cooled reactor
    Wu, Hexin
    Gou, Junli
    Yuan, Leqi
    Wang, Ruifeng
    Shan, Jianqiang
    APPLIED THERMAL ENGINEERING, 2025, 269
  • [4] Study on Heat Transfer Capability of Passive Residual Heat Removal System Based on Heat Pipe
    Xian L.
    Zhou K.
    Li F.
    Yang F.
    Zhang Z.
    Zhang D.
    Wang X.
    Hedongli Gongcheng/Nuclear Power Engineering, 2019, 40 (06): : 100 - 104
  • [5] The impact of design on the decay heat removal capabilities of a modular pebble bed HTR
    Ben Said, N
    Lohnert, G
    Buck, M
    Bernnat, W
    NUCLEAR ENGINEERING AND DESIGN, 2006, 236 (5-6) : 648 - 656
  • [6] THE APPLICATION OF HEAT PIPE DISCHARGE CONTAINMENT HEAT EXPERIMENTAL STUDY NEW TYPE OF PASSIVE CONTAINMENT HEAT REMOVAL SYSTEM CONCEPT DESIGN
    Qin, Haiqi
    Lu, Daogang
    Wang, Shengfei
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 6, 2017,
  • [7] Study on the Passive Residual Heat Removal System with Heat Pipe in Pool Type Heating Reactor
    Lyv J.
    Hedongli Gongcheng/Nuclear Power Engineering, 2024, 45 (01): : 79 - 83
  • [8] TRANSIENT STUDY ON SODIUM HEAT PIPE IN PASSIVE HEAT REMOVAL SYSTEM OF MOLTEN SALT REACTOR
    Wang, Chenglong
    Qiu, Suizheng
    Tian, Wenxi
    Wu, Yingwei
    Su, Guanghui
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 4, 2014,
  • [9] Experimental study on the transient response of passive decay heat removal system
    Vinod, V.
    Chandramouli, S.
    Padmakumar, G.
    Nashine, B. K.
    Rajan, K. K.
    NUCLEAR ENGINEERING AND DESIGN, 2014, 280 : 564 - 569
  • [10] The Passive Heat Removal Facility: Testing and Demonstrating an Innovative Decay Heat Removal System
    Caramello, M.
    Frignani, M.
    Beaumont, R.
    Tarantino, M.
    Liao, J.
    Wright, R. F.
    Durse, M.
    Wimshurst, A.
    Ferroni, P.
    NUCLEAR TECHNOLOGY, 2024, 210 (04) : 740 - 757