Polystyrene microspheres based sandwich immunosensor using CdTe nanoparticles amplification and ultrasensitive flow-injection chemiluminescence detection

被引:11
|
作者
Kanwal, Shamsa [1 ]
Traore, Zoumama [1 ]
Su, Xingguang [1 ]
机构
[1] Jilin Univ, Dept Analyt Chem, Coll Chem, Changchun 130012, Peoples R China
基金
中国国家自然科学基金;
关键词
Flow-injection analysis; Chemiluminescence; Immunoassay; CdTe nanoparticles; IMMUNOASSAY;
D O I
10.1016/j.colsurfb.2010.07.056
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this paper we propose a specific sandwich immunoassay method for human-immunoglobulin C (HIgG). This immunoassay protocol takes advantage of sandwich binding of primary and secondary antibodies for increased specificity. Polystyrene microspheres (PS) serve as immobilizing support, site for sandwich immunoassay and then subsequently used for chemiluminescence (CL) detections. In this sandwich immunoassay, PS microspheres were modified with the primary anti-HIgG (Ab(1)) via electrostatic interaction, while CdTe nanoparticles (CdTeNPs) were modified with horseradish peroxidase labeled anti-HIgG (Ab(2)) via covalent binding. Antigen HIgG (Ag) was specifically captured by the first and secondary antibody and form sandwich immunoassay format. Combination of the remarkable sensitivity of CL method and the use of CdTe NPs as anti-HIgG-HRP carrier for the enzymatic signal amplification, provide a linear response range of HIgG from 0.01 to 300 ng mL(-1) with an extremely low detection limit of 0.3 pg mL(-1). This immunoassay system has many desirable merits including sensitivity, accuracy, and little required instrumentation. The assay results were compared with enzyme-linked immunosorbent assay (ELISA), and showed relatively good reliability. Significantly the new protocol may become quite promising technique for protein immune-detection as well as DNA analysis and other biological analyses. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:549 / 554
页数:6
相关论文
共 50 条
  • [1] A Flow Injection Chemiluminescent Immunosensor for Ultrasensitive Detection of Brombuterol Based on Resin Beads and Enzymatic Amplification
    Zhou, Xinchun
    Li, Yuting
    Shi, Jing
    Zhao, Kang
    Deng, Anping
    Li, Jianguo
    FOOD ANALYTICAL METHODS, 2019, 12 (01) : 305 - 312
  • [2] A Flow Injection Chemiluminescent Immunosensor for Ultrasensitive Detection of Brombuterol Based on Resin Beads and Enzymatic Amplification
    Xinchun Zhou
    Yuting Li
    Jing Shi
    Kang Zhao
    Anping Deng
    Jianguo Li
    Food Analytical Methods, 2019, 12 : 305 - 312
  • [3] CHEMILUMINESCENCE DETECTION OF SODIUM-NITROPRUSSIDE USING FLOW-INJECTION ANALYSIS
    ALWARTHAN, AA
    TALANTA, 1994, 41 (10) : 1683 - 1688
  • [4] DETERMINATION OF TRACE AMOUNTS OF UREA BY USING FLOW-INJECTION WITH CHEMILUMINESCENCE DETECTION
    HU, XC
    TAKENAKA, N
    KITANO, M
    BANDOW, H
    MAEDA, Y
    HATTORI, M
    ANALYST, 1994, 119 (08) : 1829 - 1833
  • [5] Ultrasensitive sandwich-type electrochemical immunosensor based on trimetallic nanocomposite signal amplification strategy for the ultrasensitive detection of CEA
    Tian, Lihui
    Liu, Li
    Li, Yueyuan
    Wei, Qin
    Cao, Wei
    SCIENTIFIC REPORTS, 2016, 6
  • [6] Ultrasensitive sandwich-type electrochemical immunosensor based on trimetallic nanocomposite signal amplification strategy for the ultrasensitive detection of CEA
    Lihui Tian
    Li Liu
    Yueyuan Li
    Qin Wei
    Wei Cao
    Scientific Reports, 6
  • [7] OPTIMIZATION OF FLOW-INJECTION SYSTEMS FOR DETERMINATION OF SUBSTRATES BY MEANS OF ENZYME AMPLIFICATION REACTIONS AND CHEMILUMINESCENCE DETECTION
    HANSEN, EH
    NORGAARD, L
    PEDERSEN, M
    TALANTA, 1991, 38 (03) : 275 - 282
  • [8] A disposable Protein A-based immunosensor for flow-injection assay with electrochemical detection
    Valat, C
    Limoges, B
    Huet, D
    Romette, JL
    ANALYTICA CHIMICA ACTA, 2000, 404 (02) : 187 - 194
  • [9] Ultrasensitive flow injection chemiluminescence detection of DNA hybridization using nanoCuS tags
    Ding, Caifeng
    Zhong, Hua
    Zhang, Shusheng
    BIOSENSORS & BIOELECTRONICS, 2008, 23 (08): : 1314 - 1318
  • [10] Ultrasensitive sandwich-type electrochemical immunosensor based on a novel signal amplification strategy using highly loaded palladium nanoparticles/carbon decorated magnetic microspheres as signal labels
    Ji, Lei
    Guo, Zhankui
    Yan, Tao
    Ma, Hongmin
    Du, Bin
    Li, Yueyun
    Wei, Qin
    BIOSENSORS & BIOELECTRONICS, 2015, 68 : 757 - 762