Locked plating as an external fixator in treating tibial fractures A PRISMA-compliant systematic review

被引:13
|
作者
Luo, Peng [1 ,2 ,3 ]
Xu, Ding [4 ]
Wu, Jia [5 ]
Chen, Yi-Heng [1 ,2 ,3 ]
机构
[1] Wenzhou Med Univ, Affiliated Hosp 2, Dept Trauma Orthoped, Wenzhou, Peoples R China
[2] Wenzhou Med Univ, Yuying Childrens Hosp, Wenzhou, Peoples R China
[3] Zhejiang Prov Key Lab Orthopaed, Wenzhou, Peoples R China
[4] Shangyu Peoples Hosp Shaoxing City, Dept Trauma Orthoped, Shaoxing, Peoples R China
[5] Wenzhou Med Univ, Key Lab Lab Med, Zhejiang Prov Key Lab Med Genet, Minist Educ,Sch Lab Med & Life Sci, Wenzhou, Zhejiang, Peoples R China
关键词
external fixator; fracture fixation; locked plating; tibia; LOCKING COMPRESSION PLATE; OSTEOSYNTHESIS; BONE;
D O I
10.1097/MD.0000000000009083
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: This article is a systematic review of the published literature about the biomechanics, functional outcomes, and complications of a locked plate as an external fixator in treating tibial fractures. Methods: We searched the PubMed, Ovid Medline, Embase, ScienceDirect, and Cochrane Library databases to retrieve the relevant studies. Studies published in English and Chinese which assessed adult patients and more than 4 cases who had sustained any type of fresh tibial fracture treated with the external locking plate, provided that they reported functional outcomes, range of motion (ROM), union or complication rates, and the biomechanical studies of external locked plating are also included. Results: The electronic search strategy revealed 248 studies, and 2 studies were identified as relevant through manual search of references. Finally, 12 studies were included in this systematic review. These consist of 3 pure biomechanical studies, 8 case series, and 1 study including both of biomechanics and case series. Due to the heterogeneity of biomechanical studies, we can only conclude that external locked plate shows inferior structural stiffness than internal locked plate. The clinical studies reported that external locked plating gave a satisfactory ROM of the knee and ankle, functional outcomes, union rate, and low complication rate. Conclusions: We can only conclude that external locked plate shows inferior structural stiffness than internal locked plate because of the heterogeneity of biomechanical studies. The clinical studies showed locked plating as an external fixator in treating tibial fractures can be considered as a safe and successful procedure. However, as yet, there is unconvincing evidence that it is superior to standard techniques with regards to clinical and functional outcomes. More and well-designed studies about this technique should be carried out.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Therapeutics of xeroderma pigmentosum: A PRISMA-compliant systematic review
    Gomes de Andrade, Fernando Antonio
    de Oliveira Cavalcanti, Claudio Eduardo
    Isoldi, Felipe Contoli
    Ferreira, Lydia Masako
    INDIAN JOURNAL OF DERMATOLOGY VENEREOLOGY & LEPROLOGY, 2021, 87 (02): : 176 - 189
  • [2] Congenital vesicouterine fistulas-A PRISMA-compliant systematic review
    Jozwik, Maciej
    Jozwik, Marcin
    Zareba, Kamil
    Semczuk, Andrzej
    Modzelewska, Beata
    Jozwik, Michal
    NEUROUROLOGY AND URODYNAMICS, 2018, 37 (08) : 2361 - 2367
  • [3] Pediatric plexiform fibromyxoma A PRISMA-compliant systematic literature review
    Fukazawa, Mitsuharu
    Koga, Hiroshi
    Hiroshige, Shoji
    Matsumoto, Toshifumi
    Nakazono, Yuichi
    Yoshikawa, Yasuji
    MEDICINE, 2019, 98 (03)
  • [4] Air Pollution and Public Health: A PRISMA-Compliant Systematic Review
    Quarato, Marco
    De Maria, Luigi
    Gatti, Maria Franca
    Caputi, Antonio
    Mansi, Francesca
    Lorusso, Pietro
    Birtolo, Francesco
    Vimercati, Luigi
    ATMOSPHERE, 2017, 8 (10):
  • [5] Sexual dysfunctions and metacognitive beliefs: a PRISMA-compliant systematic review
    Olivari, Carlotta
    Di Cugno, Marco
    Caselli, Gabriele
    SEXUAL AND RELATIONSHIP THERAPY, 2024, 39 (04) : 1544 - 1558
  • [6] Cutaneous fistulization of the hydatid disease: A PRISMA-compliant systematic review
    Bahce, Zeynep Sener
    Akbulut, Sami
    Aday, Ulas
    Demircan, Firat
    Senol, Ayhan
    MEDICINE, 2016, 95 (38)
  • [7] Comparative effectiveness of azithromycin for treating scrub typhus A PRISMA-compliant systematic review and meta-analysis
    Lee, Szu-Chia
    Cheng, Yu-Jyun
    Lin, Chao-Hsu
    Lei, Wei-Te
    Chang, Hung-Yang
    Lee, Ming-Dar
    Liu, Jui-Ming
    Hsu, Ren-Jun
    Chiu, Nan-Chang
    Chi, Hsin
    Peng, Chun-Chih
    Tsai, Te-Lung
    Lin, Chien-Yu
    MEDICINE, 2017, 96 (36)
  • [8] The effect of Cotoneaster manna on neonatal jaundice: A PRISMA-compliant systematic review
    Ostovar, M.
    Marzban, M.
    Salehi, A.
    PLANTA MEDICA, 2016, 82
  • [9] The adoption of electronic medical record by physicians A PRISMA-compliant systematic review
    Dutta, Bireswar
    Hwang, Hsin-Ginn
    MEDICINE, 2020, 99 (08)
  • [10] Socioeconomic status and maternal postpartum depression: a PRISMA-compliant systematic review
    Szurek-Cabanas, Rocio
    Navarro-Carrillo, Gines
    Martinez-Sanchez, Celia Andrea
    Oyanedel, Juan Carlos
    Villalobos, Dolores
    CURRENT PSYCHOLOGY, 2024, 43 (33) : 27339 - 27350