Composite multienzyme amperometric biosensors for an improved detection of phenolic compounds

被引:16
|
作者
Serra, B [1 ]
Reviejo, AJ [1 ]
Pingarrón, JM [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, E-28040 Madrid, Spain
关键词
composite biosensors; multienzyme detection; phenolic compounds; waste waters;
D O I
10.1002/elan.200302765
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A biosensor design, in which glucose oxidase and peroxidase are coimmobilized by simple physical inclusion into the bulk of graphite-Teflon pellets, is reported for the detection of phenolic compounds. This design allows the "in situ" generation of the H2O2 needed for the enzyme reaction with the phenolic compounds, which avoids several problems detected in the performance of single peroxidase biosensors as a consequence of the presence of a high H2O2 concentration. So, a much lower surface fouling was found at the GOD-HRP biosensor in comparison with a graphite-Teflon-HRP electrode, suggesting that the controlled generation of H2O2 makes more difficult the formation of polymers from the enzyme reaction products. The construction of trienzyme biosensors, in which GOD, HRP and tyrosinase were coimmobilized into the graphite-Teflon matrix is also reported, and their performance was compared with that of GOD-HRP bienzyme electrodes. The practical applicability of the composite multienzyme amperometric biosensors was evaluated by the estimation of the phenolic compounds content in waste waters from a refinery, and the results were compared with those obtained by using a colorimetric official method based on the reaction with 4-aminoantipyrine.
引用
收藏
页码:1737 / 1744
页数:8
相关论文
共 50 条
  • [1] Amperometric determination of enzymatic activity by multienzyme biosensors
    Mutlu, S
    Alp, B
    Ozmelles, RS
    Mutlu, M
    JOURNAL OF FOOD ENGINEERING, 1997, 33 (1-2) : 81 - 86
  • [2] Flow injection amperometric detection of phenolic compounds at enzyme composite biosensors application to their monitoring during industrial waste waters purification processes
    Serra, B
    Reviejo, AJ
    Pingarrón, JM
    ANALYTICAL LETTERS, 2003, 36 (09) : 1965 - 1986
  • [3] Amperometric biosensors for phenolic compounds determination in the environmental interess samples.
    Rosatto, SS
    Freire, RS
    Durán, N
    Kubota, LT
    QUIMICA NOVA, 2001, 24 (01): : 77 - 86
  • [4] Amperometric detection of phenolic compounds by polypyrrole-based composite carbon paste electrodes
    Mailley, P
    Cummings, EA
    Mailley, S
    Cosnier, S
    Eggins, BR
    McAdams, E
    BIOELECTROCHEMISTRY, 2004, 63 (1-2) : 291 - 296
  • [5] Electrochemically Predicting Phenolic Substrates' Suitability for Detection by Amperometric Laccase Biosensors
    Fogel, Ronen
    Limson, Janice L.
    ELECTROANALYSIS, 2013, 25 (05) : 1237 - 1246
  • [6] Laccase-based biosensors for detection of phenolic compounds
    Rodriguez-Delgado, Melissa M.
    Aleman-Nava, Gibran S.
    Manuel Rodriguez-Delgado, Jose
    Dieck-Assad, Graciano
    Omar Martinez-Chapa, Sergio
    Barcelo, Damia
    Parra, Roberto
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2015, 74 : 21 - 45
  • [7] Amperometric biosensors based on LDH-ALGINATE hybrid nanocomposite for aqueous and non-aqueous phenolic compounds detection
    Sanchez-Paniagua Lopez, Marta
    Leroux, Fabrice
    Mousty, Christine
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 150 (01) : 36 - 42
  • [8] Amperometric Biosensor Based on Zirconium Oxide/Polyethylene Glycol/Tyrosinase Composite Film for the Detection of Phenolic Compounds
    Ahmad, Nor Monica
    Abdullah, Jaafar
    Yusof, Nor Azah
    Ab Rashid, Ahmad Hazri
    Abd Rahman, Samsulida
    Hasan, Md. Rakibul
    BIOSENSORS-BASEL, 2016, 6 (03):
  • [9] Graphite-Teflon-peroxidase composite electrochemical biosensors.: A tool for the wide detection of phenolic compounds
    Serra, B
    Benito, B
    Agüí, L
    Reviejo, AJ
    Pingarrón, JM
    ELECTROANALYSIS, 2001, 13 (8-9) : 693 - 700
  • [10] METALLIZED CARBONS FOR IMPROVED AMPEROMETRIC BIOSENSORS
    WANG, J
    ANGNES, L
    SAKSLUND, H
    FANG, L
    PEDRERO, M
    CHEN, Q
    LIU, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 210 : 349 - INOR