Effect of flexibility of the femoral stem on bone-remodeling and fixation of the stem in a canine total hip arthroplasty model without cement

被引:54
|
作者
Harvey, EJ
Bobyn, JD
Tanzer, M
Stackpool, GJ
Krygier, JJ
Hacking, SA
机构
[1] McGill Univ, Montreal Gen Hosp, Div Orthopaed Surg, Dept Surg, Montreal, PQ H3G 1A4, Canada
[2] McGill Univ, Montreal Gen Hosp, Jo Miller Orthopaed Res Lab, Montreal, PQ H3G 1A4, Canada
来源
关键词
D O I
10.2106/00004623-199901000-00013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to compare, with regard to fixation of the implant and femoral bone resorption, two fully porous-coated stems of different stiffnesses in a canine total hip arthroplasty model. A bilateral arthroplasty was carried out with insertion of a titanium-alloy stem (which had stiffness Properties comparable,vith those of the canine femur) on one side and with insertion of a composite stem (which was three to fivefold more flexible than the canine femur) on the contralateral side. Eight femora were evaluated at six months and eight, at eighteen months after the operation, to determine the extent of bone ingrowth, periprosthetic cortical area, intracortical porosity, and bone-remodeling. Despite the markedly greater flexibility of the composite stems, no significant difference could be defected (with the numbers available), with regard to the overall degree of femoral stress-shielding, cortical area, or cortical porosity, between these stems and the stiffer, titanium-alloy stems at either time-period. However, the composite stems had less bone ingrowth and more formation of radiopaque lines than did the titanium-alloy stems. At eighteen months, the values for bone ingrowth were 9.7 +/- 5.38 percent (mean and standard deviation) for the composite stems compared with 28.1 +/- 5.31 percent for the titanium-ahoy stems (p = 0.003). Furthermore, the histological sections from the femora containing a composite stem showed radiopaque lines indicative of fibrous ingrowth approximately threefold more often than did those from the femora containing a titanium-alloy stem (p = 0.02). CLINICAL RELEVANCE: These findings demonstrate that there seems to be an effective limit beyond which increasing the stiffness of the femoral stem relative to that of the femur cannot prevent femoral stress-shielding. Use of a composite stem with a flexibility that was above this limit resulted in a negligible alteration in femoral bone-remodeling and a significant decrease in the extent of bone ingrowth (p = 0.003), These findings seem to confirm the theory that excessive flexibility of the stem may jeopardize interface stability. This information may be helpful in the design of femoral prostheses for clinical use.
引用
收藏
页码:93 / 107
页数:15
相关论文
共 50 条
  • [1] The effect of stem length on femoral component positioning in canine total hip arthroplasty
    Dearmin, MG
    Schulz, KS
    VETERINARY SURGERY, 2004, 33 (03) : 272 - 278
  • [2] Tapered vs Cylindrical Stem Fixation in a Model of Femoral Bone Deficiency in Revision Total Hip Arthroplasty
    Russell, Robert D.
    Pierce, William
    Huo, Michael H.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (06): : 1352 - 1355
  • [3] THE EFFECT OF COLLAR AND DISTAL STEM FIXATION ON MICROMOTION OF THE FEMORAL STEM IN UNCEMENTED TOTAL HIP-ARTHROPLASTY
    WHITESIDE, LA
    EASLEY, JC
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1989, (239) : 145 - 153
  • [4] Addition of fluoride to acrylic bone cement does not improve fixation of a total hip arthroplasty stem
    Digas, Georgios
    Karrholm, Johan
    Thanner, Jonas
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (448) : 58 - 66
  • [5] The effects of femoral stem and neck length on cement strains in a canine total hip replacement model
    Dassler, CL
    Schulz, KS
    Kass, P
    Stover, SM
    VETERINARY SURGERY, 2003, 32 (01) : 37 - 45
  • [6] Femoral bone remodeling after short-stem total hip arthroplasty: a prospective densitometric study
    Hochreiter, Josef
    Mattiassich, Georg
    Ortmaier, Reinhold
    Steinmair, Martin
    Anderl, Conrad
    INTERNATIONAL ORTHOPAEDICS, 2020, 44 (04) : 753 - 759
  • [7] Femoral bone remodeling after short-stem total hip arthroplasty: a prospective densitometric study
    Josef Hochreiter
    Georg Mattiassich
    Reinhold Ortmaier
    Martin Steinmair
    Conrad Anderl
    International Orthopaedics, 2020, 44 : 753 - 759
  • [8] A tapered titanium femoral stem inserted without cement in a total hip arthroplasty - Radiographic evaluation and stability
    Mulliken, BD
    Bourne, RB
    Rorabeck, CH
    Nayak, N
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (08): : 1214 - 1225
  • [9] The biomechanical effect of the collar of a femoral stem on total hip arthroplasty
    Jeon, Insu
    Bae, Ji-Yong
    Park, Jin-Hong
    Yoon, Taek-Rim
    Todo, Mitsugu
    Mawatari, Masaaki
    Hotokebuchi, Takao
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2011, 14 (01) : 103 - 112
  • [10] Effect of stem flattening on rotational stability of a canine femoral total hip component in polymethylmethacrylate cement
    Mason, DR
    Schulz, KS
    Kass, PH
    Stover, SM
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2003, 16 (04) : 238 - 242