Characteristics of the fibroplasia and collagen expression in the abdominal wall after implant of the polypropylene mesh and polypropylene/polyglecaprone mesh in rats

被引:4
|
作者
Pessole Biondo-Simoes, Maria de Lourdes [1 ,7 ]
de Morais, Camila Gomes [2 ,7 ]
Zonato Tocchio, Anna Flavia [2 ,7 ]
de Miranda, Renata Augusta [2 ,7 ]
Pamponet Moura, Paula Almeida [2 ,7 ]
Colla, Kelly [2 ,7 ]
Robes, Rogerio Ribeiro [3 ,7 ]
Ioshii, Sergio Ossamu [4 ,5 ,7 ]
Saavedra Tomasich, Flavio Daniel [6 ,7 ]
机构
[1] Univ Fed Parana UFPR, Dept Surg, Curitiba, Parana, Brazil
[2] UFPR, Sci Initiat Program, Curitiba, Parana, Brazil
[3] UFPR, Fac Vet Med, Dept Anesthesiol, Curitiba, Parana, Brazil
[4] Pontificia Univ Catolica Parana PUCPR, Div Pathol, Curitiba, Parana, Brazil
[5] UFPR, Curitiba, Parana, Brazil
[6] UFPR, Dept Surg, Div Expt Surg, Curitiba, Parana, Brazil
[7] Univ Fed Parana UFPR, Div Expt Surg, Curitiba, Parana, Brazil
关键词
Surgical Mesh; Hernia; Ventral; Wound Healing; Collagen; Rats; INCISIONAL HERNIA; TENSILE-STRENGTH; REPAIR; PROSTHESES; SUTURE; DEFECT;
D O I
10.1590/S0102-865020160050000001
中图分类号
R61 [外科手术学];
学科分类号
摘要
PURPOSE: To compare fibroplasia and the resistance of the abdominal wall when polypropylene meshes and polypropylene/poliglecaprone are used. METHODS: Seventy-seven male Wistar rats were divided into three groups: Control Group (for resistance); Group E (polypropylene mesh); and Group U (polypropylene/poliglecaprone mesh). The animals in Groups E and U had a standard muscular and aponeurotic defect, with integral peritoneum, and correction with the mesh. Measurements were taken 4, 7, 14, 28 and 56 days after surgery. The resistance, and collagen density were studied. RESULTS: Resistance on the 56th day was similar in both meshes. The gain in resistance described an ascending curve for the polypropylene mesh and was irregular in the case of the polypropylene/poliglecaprone. Fibroplasia showed a gain in type I and type III collagen in both groups (p<0.001). Collagen III stabilized in the 14th day and collagen I continued to ascend. CONCLUSIONS: The gain in resistance of the polypropylene mesh is regular and ascending, whereas the polypropylene/poliglecaprone is not regular. The final resistance of both meshes is similar; the collagen density increases over time, and show the same inflammatory potential.
引用
收藏
页码:294 / 299
页数:6
相关论文
共 50 条
  • [1] Fibroplasia after polypropylene mesh implantation for abdominal wall hernia repair in rats
    Vazi, Marcia
    Krebs, Rodrigo Ketzer
    Trindade, Eduardo Neubarth
    Maciel Trindade, Manoel Roberto
    ACTA CIRURGICA BRASILEIRA, 2009, 24 (01) : 19 - 25
  • [2] Inflammatory reaction and tensile strength of the abdominal wall after an implant of polypropylene mesh and polypropylene/poliglecaprone mesh for abdominal wall defect treatment in rats
    Pessole Biondo-Simoes, Maria de Lourdes
    Pamponet Moura, Paula Almeida
    Colla, Kelly
    Zonato Tocchio, Anna Flavia
    de Morais, Camila Gomes
    de Miranda, Renata Augusta
    Robes, Rogerio Ribeiro
    Ioshii, Sergio Ossamu
    ACTA CIRURGICA BRASILEIRA, 2014, 29 : 45 - 51
  • [3] Collagen/Polypropylene Composite Mesh Biocompatibility in Abdominal Wall Reconstruction
    Lukasiewicz, Aleksander
    Skopinska-Wisniewska, Joanna
    Marszalek, Andrzej
    Molski, Stanislaw
    Drewa, Tomasz
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2013, 131 (05) : 731E - 740E
  • [4] Effect of copaiba oil on correction of abdominal wall defect treated with the use of polypropylene/polyglecaprone mesh
    Yasojima, Edson Yuzur
    Costa Teixeira, Renan Kleber
    Houat, Abdallah de Paula
    da Silva Costa, Felipe Lobato
    Silveira, Edvaldo Lima
    Henriques Brito, Marcus Vinicius
    Lopes Filho, Gaspar de Jesus
    ACTA CIRURGICA BRASILEIRA, 2013, 28 (02) : 131 - 135
  • [5] Biomechanical effects of polyglecaprone fibers in a polypropylene mesh after abdominal and rectovaginal implantation in a rabbit
    Ozog, Yves
    Mazza, Edoardo
    De Ridder, Dirk
    Deprest, Jan
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2012, 23 (10) : 1397 - 1402
  • [6] Biomechanical effects of polyglecaprone fibers in a polypropylene mesh after abdominal and rectovaginal implantation in a rabbit
    Yves Ozog
    Edoardo Mazza
    Dirk De Ridder
    Jan Deprest
    International Urogynecology Journal, 2012, 23 : 1397 - 1402
  • [8] POLYPROPYLENE MESH CLOSURE OF THE ABDOMINAL-WALL
    SCHEIN, M
    SAADIA, R
    DECKER, GAG
    BRITISH JOURNAL OF SURGERY, 1986, 73 (07) : 594 - 594
  • [9] The optical analysis of the abdominal wall using the biospeckle after implants of polypropylene mesh in rats
    Nieri, Tamara Maria
    de Oliveira Peres, Marco Antonio
    da Silva, Emerson Rodrigo
    Dal Fabbro, Inacio Maria
    Muramatsu, Mikiya
    Andreollo, Nelson Adami
    ACTA CIRURGICA BRASILEIRA, 2009, 24 (06) : 442 - 448
  • [10] Analysis of tissue inflammatory response, fibroplasia, and foreign body reaction between the polyglactin suture of abdominal aponeurosis in rats and the intraperitoneal implant of polypropylene, polypropylene/polyglecaprone and polyester/porcine collagen meshes
    Ribeiro, Waston Goncalves
    Correa Nascimento, Adriana Carneiro
    Ferreira, Larissa Brito
    De Marchi, Danilo Dallago
    Rego, Gustavo Moraes
    Maeda, Carlos Toshinori
    Barros Silva, Gyl Eanes
    Neto, Ricardo Artigiani
    Martins Torres, Orlando Jorge
    Pitombo, Marcos Bettini
    ACTA CIRURGICA BRASILEIRA, 2021, 36 (07)