Surface oxide net charge of a titanium alloy Comparison between effects of treatment with heat or radiofrequency plasma glow discharge

被引:27
|
作者
MacDonald, Daniel E. [1 ,2 ,3 ]
Rapuano, Bruce E. [1 ]
Schniepp, Hannes C. [4 ]
机构
[1] Cornell Univ, Weill Med Coll, Hosp Special Surg, New York, NY 10021 USA
[2] Gen Med Res James Peters VA Med Ctr, Bronx, NY 10468 USA
[3] Columbia Univ, Langmuir Ctr Colloids & Interfaces, New York, NY 10027 USA
[4] Coll William & Mary, Dept Appl Sci, Williamsburg, VA 23185 USA
关键词
Titanium alloy; Oxides; Surface treatments; Net surface charge; Wettability; OSTEOBLAST-LIKE CELLS; PHYSIOLOGICAL SOLUTION; FIBRONECTIN; ADSORPTION; FILMS; ROUGHNESS; IMPLANTS; BEHAVIOR; PLATES;
D O I
10.1016/j.colsurfb.2010.08.031
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In the current study we have compared the effects of heat and radiofrequency plasma glow discharge (RFGD) treatment of a Ti6Al4V alloy on the physico chemical properties of the alloys surface oxide Titanium alloy (Ti6Al4V) disks were passivated alone heated to 600 C or RFGD plasma treated in pure oxygen RFGD treatment did not alter the roughness topography elemental composition or thickness of the alloys surface oxide layer In contrast heat treatment altered oxide topography by creating a pattern of oxide elevations approximately 50-100 nm in diameter These nanostructures exhibited a three fold increase in roughness compared to untreated surfaces when RMS roughness was calculated after applying a spatial high-pass filter with a 200 nm cutoff wavelength Heat treatment also produced a surface enrichment in aluminum and vanadium oxides Both RFGD and heat treatment produced similar increases in oxide wettability Atomic force microscopy (AFM) measurements of metal surface oxide net charge signified by a long-range force of attraction to or repulsion from a (negatively charged) silicon nitride AFM probe were also obtained for all three experimental groups Force measurements showed that the RFGD treated Ti6Al4V samples demonstrated a higher net positive surface charge at pH values below 6 and a higher net negative surface charge at physiological pH (pH values between 7 and 8) compared to control and heat treated samples These findings suggest that RFGD treatment of metallic implant materials can be used to study the role of negatively charged surface oxide functional groups in protein bioactivity osteogenic cell behavior and osseointegration independently of oxide topography Published by Elsevier B V
引用
收藏
页码:173 / 181
页数:9
相关论文
共 22 条
  • [1] Heat and Radiofrequency Plasma Glow Discharge Pretreatment of a Titanium Alloy Promote Bone Formation and Osseointegration
    MacDonald, Daniel E.
    Rapuano, Bruce E.
    Vyas, Parth
    Lane, Joseph M.
    Meyers, Kathleen
    Wright, Timothy
    JOURNAL OF CELLULAR BIOCHEMISTRY, 2013, 114 (10) : 2363 - 2374
  • [2] Heat and radiofrequency plasma glow discharge pretreatment of a titanium alloy: Eveidence for enhanced osteoinductive properties
    Rapuano, Bruce E.
    Singh, Herman
    Boskey, Adele L.
    Doty, Stephen B.
    MacDonald, Daniel E.
    JOURNAL OF CELLULAR BIOCHEMISTRY, 2013, 114 (08) : 1917 - 1927
  • [3] Study on Glow Discharge Plasma Aluminizing on Titanium Alloy Surface
    Chen Fei
    Zhou Hai
    Pan Junde
    RARE METAL MATERIALS AND ENGINEERING, 2008, 37 (10) : 1844 - 1846
  • [4] Study on glow discharge plasma aluminizing on titanium alloy surface
    Beijing Institute of Petrochemical Technology, Beijing 102617, China
    不详
    Xiyou Jinshu Cailiao Yu Gongcheng, 2008, 10 (1844-1846):
  • [5] Heat and Radiofrequency Plasma Glow Discharge Pretreatment of a Titanium Alloy: Evidence for Enhanced Osteoinductive Properties (vol 114, pg 1917, 2013)
    Rapuano, Bruce E.
    Singh, Herman
    Boskey, Adele L.
    Doty, Stephen B.
    MacDonald, Daniel E.
    JOURNAL OF CELLULAR BIOCHEMISTRY, 2013, 114 (09) : 2201 - 2201
  • [6] Heat or radiofrequency plasma glow discharge treatment of a titanium alloy stimulates osteoblast gene expression in the MC3T3 osteoprogenitor cell line
    Rapuano, Bruce E.
    Hackshaw, Kyle
    MacDonald, Daniel E.
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2012, 42 (03): : 95 - 104
  • [7] Glow discharge plasma treatment of titanium surface enhances cell adhesion.
    Niida, A.
    Hirose, Y.
    Kuniyasu, H.
    Ochi, M.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B273 - B273
  • [8] Titanium-oxide thickness of machined and cast titanium and titanium alloy influenced by radio-frequency-glow-discharge treatment.
    Carneiro, LC
    Kemp, PL
    Louw, W
    Botha, SJ
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 617 - 617
  • [9] Properties of Ti-Al Alloying Layer on Titanium Alloy Surface by Double Glow Discharge Plasma Aluminizing
    Chen Fei
    Chen Jia-qing
    Zhou Hai
    Lv Fan-xiu
    VACUUM TECHNOLOGY AND SURFACE ENGINEERING - PROCEEDINGS OF THE 9TH VACUUM METALLURGY AND SURFACE ENGINEERING CONFERENCE, 2009, : 46 - 51
  • [10] The preparation processing parameter study of the double glow discharge plasma hydrogen-free carburizing on titanium alloy surface
    Zhang, Gao-Hui
    Zhang, Ping-Ze
    Ge, Hong-Liang
    Cui, Yu-Jian
    Jiang, Wei-Di
    Xu, Zhong
    Cailiao Rechuli Xuebao/Transactions of Materials and Heat Treatment, 2007, 28 (SUPPL.): : 110 - 114