A new approach to thermodynamic analysis of ejector-absorption cycle:: artificial neural networks

被引:84
|
作者
Sözen, A [1 ]
Arcaklioglu, E
Özalp, M
机构
[1] Gazi Univ, Mech Educ Dept, Tech Educ Fac, TR-06503 Ankara, Turkey
[2] Kirikkale Univ, Dept Mech Engn, Fac Engn, TR-71450 Kirikkale, Turkey
关键词
artificial neural network; absorption refrigeration; thermodynamic properties; methanol/LiBr; COP;
D O I
10.1016/S1359-4311(03)00034-6
中图分类号
O414.1 [热力学];
学科分类号
摘要
Thermodynamic analysis of absorption thermal systems is too complex because of analytic functions calculating the thermodynamic properties of fluid couples involving the solution of complex differential equations. To simplify this complex process, the use of artificial neural networks (ANNs) has been proposed for the analysis of ejector-absorption refrigeration systems (EARSs). ANNs approach was used to determine the properties of liquid and two phase boiling and condensing of an alternative working fluid couple (methanol/LiBr), which does not cause ozone depletion for EARS. The back-propagation learning algorithm with three different variants and logistic sigmoid transfer function was used in the network. In addition, this paper presents a. comparative performance study of the. EARS using both analytic functions and prediction of ANN for properties of the fluid couple. After training, it was found that average error is less than 1.3% and R-2 values are about 0.9999. Additionally, when the results of analytic equations obtained by using experimental data. and by means of ANN were compared, deviations in coefficient of performance (COP), exergetic coefficient of performance (ECOP) and circulation ratio (F) for all working temperatures were found to be less than 1.8%, 4%, 0.2%, respectively. Deviations for COP, ECOP and F at a generator temperature of similar to90 degreesC for which the COP of the system is maximum are 1%, 2%, 0.1%; respectively, for other working temperatures. As seen from the results obtained, the calculated thermodynamic properties-are obviously within acceptable uncertainties. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:937 / 952
页数:16
相关论文
共 50 条
  • [1] Thermodynamic analysis of ejector-absorption refrigeration cycle using the second thermodynamic law
    Alexis, G. K.
    INTERNATIONAL JOURNAL OF EXERGY, 2014, 14 (02) : 179 - 190
  • [2] Exergy analysis of an ejector-absorption heat transformer using artificial neural network approach
    Sozen, Adnan
    Arcaklioglu, Erol
    APPLIED THERMAL ENGINEERING, 2007, 27 (2-3) : 481 - 491
  • [3] Modelling (using artificial neural-networks) the performance parameters of a solar-driven ejector-absorption cycle
    Sözen, A
    Akçayol, MA
    APPLIED ENERGY, 2004, 79 (03) : 309 - 325
  • [4] Parametric analysis for a new combined power and ejector-absorption refrigeration cycle
    Wang, Jiangfeng
    Dai, Yiping
    Zhang, Taiyong
    Ma, Shaolin
    ENERGY, 2009, 34 (10) : 1587 - 1593
  • [5] Reformulation, as a function of only working temperatures, of performance parameters of a solar driven ejector-absorption cycle using artificial neural networks
    Sözen, A
    Akçayol, MA
    ENERGY SOURCES, 2005, 27 (12): : 1133 - 1149
  • [6] A novel ejector-absorption combined refrigeration cycle
    Hong, Daliang
    Chen, Guangming
    Tang, Limin
    He, Yijian
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (07): : 1596 - 1603
  • [7] Thermodynamic analysis and comparison of combined ejector-absorption and single effect absorption refrigeration systems
    Farshi, L. Garousi
    Mosaffa, A. H.
    Ferreira, C. A. Infante
    Rosen, M. A.
    APPLIED ENERGY, 2014, 133 : 335 - 346
  • [8] Thermodynamic analysis of the ejector refrigeration cycle using the artificial neural network
    Rashidi, M. M.
    Aghagoli, A.
    Raoofi, R.
    ENERGY, 2017, 129 : 201 - 215
  • [9] Study of an ejector-absorption refrigeration cycle with an adaptable ejector nozzle for different working conditions
    Vereda, C.
    Ventas, R.
    Lecuona, A.
    Venegas, M.
    APPLIED ENERGY, 2012, 97 : 305 - 312
  • [10] Thermodynamic analysis of a biomass gasifier driven combined power and ejector-absorption refrigeration (CPER) system
    Parvez M.