Reliability of Estimating Ductions in Thyroid Eye Disease An International Thyroid Eye Disease Society Multicenter Study

被引:38
|
作者
Dolman, Peter J. [1 ]
Cahill, Kenneth [2 ]
Czyz, Craig N. [3 ]
Douglas, Raymond S. [4 ]
Elner, Victor M. [4 ]
Feldon, Steven [5 ]
Kazim, Michael [6 ]
Lucarelli, Mark [7 ]
Sivak-Collcott, Jennifer [8 ]
Stacey, Andrew W. [2 ]
Strianese, Diego [9 ]
Uddin, Jimmy [10 ]
机构
[1] Univ British Columbia, Dept Ophthalmol, Eye Care Ctr, Vancouver, BC V5Z 3N9, Canada
[2] Ohio State Univ, Sch Med, Columbus, OH 43210 USA
[3] OhioHllth Doctors Hosp, Columbus, OH USA
[4] Univ Michigan Hlth Syst, Ann Arbor, MI USA
[5] Univ Rochester, Med Ctr, Rochester, NY 14642 USA
[6] Columbia Univ Hosp, New York, NY USA
[7] Univ Wisconsin Madison, Madison, WI USA
[8] W Virginia Univ, Morgantown, WV 26506 USA
[9] Univ Naples Federico 2, Naples, Italy
[10] Moorfields Eye Hosp, London, England
关键词
GRAVES OPHTHALMOPATHY; UNIOCULAR FIELDS; CLASSIFICATION; ORBITOPATHY; FIXATION;
D O I
10.1016/j.ophtha.2011.07.011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine intraobserver and interobserver reliability of 3 clinical techniques for measuring ocular ductions in patients with thyroid eye disease and to compare these with an established method using a Goldmann perimeter. Our secondary goals were to compare the clinical methods for test duration, ease of learning and performance, and whether these differed between novices and experts. Design: Multicenter, prospective, comparative trial. Participants: We recruited 38 patients with thyroid orbitopathy and reduced ocular motility from 7 academic centers. Methods: At each center, 2 novices and 2 experts measured the ocular ductions of each eye of each patient in 4 directions (0 degrees, 90 degrees, 180 degrees, and 270 degrees) using 3 techniques (best guess [BG], light reflex [LR], and a ruler measuring [RU] technique). Test duration and clinicians' feedback were recorded. A subjective and objective measurement for ocular ductions using a Goldmann perimeter was performed for each subject by a trained technician. The 3 clinical measurements and the perimetry measurements were performed twice, separated by >= 1 hour. Main Outcome Measures: We measured the intraobserver and interobserver reliability of the 3 clinical techniques and intraobserver reliability of Goldmann perimeter. Clinical testing reliability was compared between experts and novices. We also examined test duration and clinician feedback. Results: The LR technique had significantly better intraobserver and interobserver repeatability compared with the BG or RU clinical measurements and statistically was equivalent to the gold-standard perimetric technique. Reliability was constant regardless of the amount of restriction in ocular movement. There was no difference between reliability values for experts and novices. The LR and BG techniques were significantly faster than the RU or perimetry techniques and were considered easiest to learn and perform, but clinicians had most confidence in the LR technique results. Conclusions: The LR technique for measuring ocular ductions in thyroid orbitopathy is more reliable than other clinical techniques and as reliable as the established technique using the perimeter. However, unlike the latter method, it is easier to learn and perform by both novices and experts, is significantly faster, and can be performed by the clinician without machinery or a trained technician. Financial Disclosure(s): The authors have no proprietary or commercial interest in any of the materials discussed in this article. Ophthalmology 2012;119:382-389 (C) 2012 by the American Academy of Ophthalmology.
引用
收藏
页码:382 / 389
页数:8
相关论文
共 50 条
  • [1] Soft Tissue Metrics in Thyroid Eye Disease: An International Thyroid Eye Disease Society Reliability Study
    Mawn, Louise A.
    Dolman, Peter J.
    Kazim, Michael
    Strianese, Diego
    Genol, Ignacio
    Chong, Kelvin K. L.
    Sullivan, Timothy J.
    Korn, Bobby S.
    Naik, Milind
    Dutton, Jonathan
    Velasco e Cruz, Augusto
    Li, Chun
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2018, 34 (06): : 544 - 546
  • [2] International Thyroid Eye Disease Society
    Sullivan, Timothy
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2023, 39 (6S): : S1 - S1
  • [3] Axial Globe Position Measurement: A Prospective Multicenter Study by the International Thyroid Eye Disease Society
    Bingham, Chad M.
    Sivak-Callcott, Jennifer A.
    Gurka, Matthew J.
    Nguyen, John
    Hogg, Jeffery P.
    Feldon, Steve E.
    Fay, Aaron
    Seah, Lay-Leng
    Strianese, Diego
    Durairaj, Vikram D.
    Uddin, Jimmy
    Devoto, Martin H.
    Harris, Matheson
    Saunders, Justin
    Osaki, Tammy H.
    Looi, Audrey
    Teo, Livia
    Davies, Brett W.
    Elefante, Andrea
    Shen, Sunny
    Realini, Tony
    Fischer, William
    Kazim, Michael
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2016, 32 (02): : 106 - 112
  • [4] Ocular ductions after rectus muscle recession and resection in thyroid eye disease
    Matlach, Juliane
    Doellinger, Vera K. R.
    Eha, Judith
    Elflein, Heike M.
    Weyer-Elberich, Veronika
    Mildenberger, Philipp
    Pitz, Susanne
    STRABISMUS, 2019, 27 (03) : 143 - 148
  • [5] Thyroid eye disease
    Char, DH
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1996, 80 (10) : 922 - 926
  • [6] Thyroid eye disease
    Wayne Todd Cornblath
    Current Treatment Options in Neurology, 2000, 2 (5) : 401 - 405
  • [7] THYROID EYE DISEASE
    CLIFTONBLIGH, P
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1990, 18 (03): : 233 - 235
  • [8] Thyroid eye disease
    Perros, Petros
    Neoh, Christopher
    Dickinson, Jane
    BRITISH MEDICAL JOURNAL, 2009, 338 : 645 - 650
  • [9] THYROID EYE DISEASE
    ELSTON, JS
    EYE, 1990, 4 : R7 - R7
  • [10] Thyroid Eye Disease
    Cockerham, Kimberly P.
    Chan, Stephanie S.
    NEUROLOGIC CLINICS, 2010, 28 (03) : 729 - +