Remote verification in radiotherapy using digitally reconstructed radiography (DRR) and portal images: A pilot study

被引:9
|
作者
Hashimoto, S
Shirato, H
Nishioka, T
Kagei, K
Shimizu, S
Fujita, K
Ogasawara, H
Watanabe, Y
Miyasaka, K
机构
[1] Hokkaido Univ, Sch Med, Dept Radiol, Kita Ku, Sapporo, Hokkaido 060, Japan
[2] Otaru Metropolitan Hosp, Otaru, Hokkaido, Japan
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2001年 / 50卷 / 02期
关键词
DRR; telecommunication; portal image; distant consultation; JPEG;
D O I
10.1016/S0360-3016(01)01485-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To use digitally reconstructed radiography (DRR) and digitally compressed portal images in distant consultation using a telecommunications network, the verification performance of DRR and digitally compressed portal images on the image console was investigated. Methods and Materials: A human thoracic phantom was scanned with computed tomography (CT). Radiotherapy was planned at 5 different anatomic locations. A digitally reconstructed radiograph was made; verification films of the phantom were then taken with 6-MV X-rays. The treatment center was intentionally dislocated, Fifty sets of DRR and portal images were seen by 7 doctors on a conventional view-box (view-box method) to judge whether the treatment center was dislocated. These image sets were digitalized by a film scanner, compressed to 1/10 Joint Photographic Experts Group (JPEG) format, and compared on an image console by the same physicians (image-console method). The verification performance of the image console method was compared with that of the view-box method by means of receiver operating characteristic (ROC) analysis. Clinically, 159 portal-image-sets were verified with the image-console method and the appropriateness of the decision was later assessed by the view-box method. Results: The accuracy of the treatment verification was estimated to be 88.8% by the conventional view-box method and 88.3% by the image-console method. There was no statistically significant difference in the verification performances of the conventional method (Az = 0.86 +/- 0.02) and the image console method (Az = 0.84 +/- 0.07). Frequent digital image-processing modification was positively related to the accuracy of verification. Clinically, there were 3 (1.8%) major corrections, 31 (19.5%) minor corrections, and 123 cases,vith no correction. No further correction was called for by the re-evaluation using the view-box method. Conclusion: The verification performance of DRR and digitally compressed portal images on the image console was as accurate as the conventional method. Distant consultation using DRR and portal images through telecommunication is usable in clinical practice. (C) 2001 Elsevier Science Inc.
引用
收藏
页码:579 / 585
页数:7
相关论文
共 50 条
  • [1] Treatment verification using digitally reconstructed radiographs (DRR) and electronic portal images (EPI) -: Image quality considerations
    Horst, E
    Pöttgen, C
    Lübcke, W
    Heintz, M
    Stuschke, M
    STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 : 71 - 71
  • [2] Automated patient positioning verification using orthogonal DRR and portal images
    Yan, Y
    Papanikolaou, N
    Penagaricano, J
    Ratanatharathorn, V
    Pawlicki, T
    Luxton, G
    Boyer, A
    MEDICAL PHYSICS, 2002, 29 (06) : 1244 - 1244
  • [3] Three-dimensional anatomy setup verification by correlation of orthogonal portal images and digitally reconstructed radiographs
    Sirois, LM
    Hristov, DH
    Fallone, BG
    MEDICAL PHYSICS, 1999, 26 (11) : 2422 - 2428
  • [4] Measurement of patient setup errors using digitally reconstructed radiographs and electronic portal images
    Ureten, O
    Erkal, HS
    PROCEEDINGS OF THE 1998 2ND INTERNATIONAL CONFERENCE BIOMEDICAL ENGINEERING DAYS, 1998, : 88 - 90
  • [5] PATIENT POSITION VERIFICATION: CONTRIBUTIONS OF PORTAL IMAGES, DRR AND REGISTRATION SOFTWARE
    Pallotta, S.
    Bucciolini, M.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S168 - S168
  • [6] An image correlation procedure for digitally reconstructed radiographs and electronic portal images
    Dong, L
    Boyer, AL
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05): : 1053 - 1060
  • [8] TOWARDS POSITION-VERIFICATION USING CT IMAGES RECONSTRUCTED FROM VMAT PORTAL IMAGES
    Poludniowski, G.
    Thomas, M.
    Evans, P.
    Webb, S.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S186 - S186
  • [9] Verification of quality parameters for portal images in radiotherapy
    Pesznyak, Csilla
    Polgar, Istvan
    Weisz, Csaba
    Kiraly, Reka
    Zarand, Pal
    RADIOLOGY AND ONCOLOGY, 2011, 45 (01) : 68 - 74
  • [10] Procedures for high precision setup verification and correction of lung cancer patients using CT-simulation and digitally reconstructed radiographs (DRR)
    de Koste, JRV
    de Boer, HCJ
    Schuchhard-Schipper, RH
    Senan, S
    Heijmen, BJM
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (03): : 804 - 810