Gas Chromatographic Determination of Bifenthrin in Technical and Selected Formulated Products: Collaborative Study

被引:0
|
作者
Kikta, Eimard J., Jr. [1 ]
机构
[1] FMC Corp, Agr Prod Grp, Princeton S Corp Ctr 701, Ewing, NJ 08628 USA
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A GC method for the analysis of technical and formulated bifenthrin samples was evaluated in a collaborative study. Bifenthrin is determined by using a 50% (trifluoropropyl)-methylpolysiloxane wide-bora capillary column and flame ionization detector. Ten samples, consisting of four formulations and a technical material were analyzed by 12 collaborators using Youden pairs. The four formulation types included in this study were microemulsion (ME), wettable powder (WP), suspension concentrate (SC), and emulsifiable concentrate (EC). Variability in the analysis of two of the formulation types, SC and EC, was later found to be due to the noncommercial containers used to hold the test samples. Because of this, valid data could not be obtained for the EC and SC. For the two formulations for which valid data could be obtained, ME and WP, and the technical chemical, accuracy and variability results are typical 01 large data sets. For the technical chemical and the two formulations for which valid data were obtained, Official First Action is recommended.
引用
收藏
页码:453 / 458
页数:6
相关论文
共 50 条