Experiment and simulation study on convective heat transfer of all-glass evacuated tube solar collector

被引:27
|
作者
Li, Qiong [1 ]
Gao, Wenfeng [1 ]
Lin, Wenxian [2 ]
Liu, Tao [1 ]
Zhang, Yougang [1 ]
Ding, Xiang [1 ]
Huang, Xiaoqiao [1 ]
Liu, Wuming [3 ]
机构
[1] Yunnan Normal Univ, Solar Energy Res Inst, Kunming 650500, Yunnan, Peoples R China
[2] James Cook Univ, Sch Engn, Townsville, Qld 4811, Australia
[3] Chinese Acad Sci, Inst Phys, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Solar collector; Evacuated tube; Heat transfer; Declination angle; Natural circulation; THERMAL PERFORMANCE; MATHEMATICAL-MODEL; WATER-HEATERS; PIPE; FLOW; ENERGY; EFFICIENCY;
D O I
10.1016/j.renene.2020.01.089
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Solar collector with horizontal double-row all-glass evacuated tubes has been extensively implemented in the solar water heating system engineering. The temperature distribution and stratification of horizontal double-row all-glass evacuated tube collector with 24 evacuated tubes have been studied. Validation of instantaneous efficiency under different declination angle theta(m) were studied by means of experiments. Moreover, numerical simulations are carried out for four different declination angle theta(m) (0 degrees/2 degrees/4 degrees/6 degrees). The results showed that the declination angle theta(m) has significant effect on energy conversion efficiency, flow patterns and stratification inside evacuated tubes. When theta(m) > 0, with the declination angle increased, the instantaneous efficiency also increased, nevertheless, the temperature stratification weakened and the heat loss coefficient demonstrated no significant change. Declination angle 6 degrees allowed to achieve significant higher temperatures, nevertheless, along with inactive area at the bottom of evacuated tubes appears. If declination angle theta(m) < 0, inversion phenomenon appears. With the increase of |theta(m)|, more heat is trapped in the sealed end of the evacuated tube, which is not conducive to the flow heat transfer in evacuated tube solar collector. (c) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1129 / 1139
页数:11
相关论文
共 50 条
  • [1] Experiment and simulation for convective heat transfer in all-glass evacuated tube solar collectors
    Zhang T.
    Han J.
    Tian R.
    Yu Z.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2016, 32 (05): : 206 - 212
  • [2] The Study of Solar Heat Pump with all-glass evacuated tube
    Gao, Jinshui
    Ge, Xin
    2009 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-3, 2009, : 778 - +
  • [3] Experimental study on the natural convective heat transfer in a horizontally disposed all glass evacuated solar collector tube
    Wang, Li-ting
    Lu, wei-de
    Huo, Zhi-chen
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 1989, 10 (02): : 177 - 184
  • [4] Simulation Study of Influence of Inertia of Water on the Thermal Performance of All-glass Evacuated Tube Solar Collector
    Gao, Yan
    An, Yujiao
    Li, Deying
    Chen, Yanhong
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [5] Experimental research on the all-glass evacuated tube solar air collector
    Liang, Hong
    PROCEEDINGS OF ISES SOLAR WORLD CONGRESS 2007: SOLAR ENERGY AND HUMAN SETTLEMENT, VOLS I-V, 2007, : 674 - 677
  • [6] Performance studies of novel all-glass heat pipe evacuated collector tube integrating numerical simulation and experiment method
    Gong, Jing-hu
    Sun, Zhi-hao
    Wang, Jun
    Lund, Peter D.
    SOLAR ENERGY, 2023, 253 : 491 - 500
  • [7] Experimental and simulation study for all-glass evacuated tube solar water heaters
    Zhang, Tao
    Han, Jitian
    Tian, Rui
    Yu, Zeting
    Shi, Rutao
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2015, 45 (05): : 897 - 902
  • [8] DEGRADATION OF ALL-GLASS EVACUATED SOLAR COLLECTOR TUBES
    CHOW, SP
    HARDING, GL
    COLLINS, RE
    SOLAR ENERGY MATERIALS, 1985, 12 (01): : 1 - 41
  • [9] A Study on Thermal Performance of a Novel All-Glass Evacuated Tube Solar Collector Manifold Header with an Inserted Tube
    Yang, Jichun
    Jiang, Qingyang
    Hou, Jingxin
    Luo, Chenglong
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2015, 2015
  • [10] An experimental study on the impacts of key parameters of all-glass evacuated tubes on the thermal performances of all-glass evacuated tube solar water heaters
    Ma, Fangfang
    Gao, Wenfeng
    Liu, Tao
    Lin, Wenxian
    Li, Ming
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2013, 5 (02)