Hammering force during cementless total hip arthroplasty and risk of microfracture

被引:23
|
作者
Sakai, Rina [1 ]
Takahashi, Akiko [1 ]
Takahira, Naonobu [2 ]
Uchiyama, Katsufumi [2 ]
Yamamoto, Takeaki [2 ]
Uchida, Kentaro [2 ]
Fukushima, Kensuke [2 ]
Moriya, Mistutoshi [2 ]
Takaso, Masashi [2 ]
Itoman, Moritoshi [3 ]
Mabuchi, Kiyoshi [1 ]
机构
[1] Kitasato Univ, Dept Med Engn & Technol, Sch Allied Hlth Sci, Sagamihara, Kanagawa 2520329, Japan
[2] Kitasato Univ, Dept Orthopaed Surg, Sch Med, Sagamihara, Kanagawa 2520329, Japan
[3] Kyushu Rosai Hosp, Kitaksyushu City, Fukuoka, Japan
关键词
Cementless stem; Press-fit; Hammering; Periprosthetic fracture; Total hip arthroplasty; FEMORAL FRACTURES; STEMS;
D O I
10.5301/HIP.2011.8408
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
During cementless stem fixation, impaction of the stem is occasionally complicated by bony injuries. Small fractures not visible to the eye during surgery or on post-operative radiographs may remain undetected, and the incidence of such injuries may be underestimated. Employing the same techniques as those employed during total hip arthroplasty, we implanted cementless stems into artificial femora, with equivalent mechanical characteristics to living femora. The hammering force applied to the femur and the displacement of the stem and femur were measured using a load sensor and imaging, respectively. The von Mises stress generated in the femur during cementless stem press-fixation was also measured using finite element analysis. Average hammering force under these conditions (9.25 kN) was sufficient to cause damage to the artificial femur. The first two of eight hammer strikes caused most displacement of the stem. The von Mises stresses generated by the first and second hammer strikes were 31 and 68 MPa, respectively. Applying a high average hammering force to the stem after displacement has ceased probably contributes to the generation of intraoperative fractures during cementless stem fixation. Given that two strikes appeared to be sufficient, we believe that hammering force should be reduced to a micro-adjustment level after the second hit.
引用
收藏
页码:330 / 335
页数:6
相关论文
共 50 条
  • [1] Weak hammering sounds are associated with postoperative subsidence in cementless total hip arthroplasty
    Homma, Yasuhiro
    Tashiro, Ken
    Okuno, Ryuji
    Unoki, Masashi
    Murakami, Yuki
    Watari, Taiji
    Baba, Tomonori
    Ishijima, Muneaki
    INTERNATIONAL ORTHOPAEDICS, 2025, 49 (02) : 421 - 428
  • [2] Measurement of the impact force of the femoral component during cementless total hip arthroplasty
    Shinoda, Tsuyoshi
    Naito, Masatoshi
    Moriyama, Shigeaki
    Shiramizu, Kei
    Ishiko, Toshiyuki
    CURRENT ORTHOPAEDIC PRACTICE, 2009, 20 (05): : 552 - 556
  • [3] Patients With Shorter Stature Exhibit Minimal Hammering Sound Changes During Cementless Stem Insertion in Total Hip Arthroplasty
    Homma, Yasuhiro
    Zhuang, Xu
    Yanagisawa, Naotake
    Ishii, Seiya
    Baba, Tomonori
    Ishijima, Muneaki
    ARTHROPLASTY TODAY, 2023, 21
  • [4] Cementless Total Hip Arthroplasty in Octogenarians
    Stihsen, Christoph
    Springer, Bernhard
    Nemecek, Elena
    Olischar, Boris
    Kaider, Alexandra
    Windhager, Reinhard
    Kubista, Bernd
    JOURNAL OF ARTHROPLASTY, 2017, 32 (06): : 1923 - 1929
  • [5] CEMENTLESS TOTAL HIP-ARTHROPLASTY
    MORSCHER, EW
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1983, (181) : 76 - 91
  • [6] VASCULAR INJURY DURING CEMENTLESS TOTAL HIP-ARTHROPLASTY
    BRIEN, WW
    SARMIENTO, A
    ORTHOPEDICS, 1992, 15 (01) : 54 - 56
  • [7] Cementless total hip arthroplasty: a review
    Diehl, Peter
    Haenle, Maximilian
    Bergsehmidt, Philipp
    Gollwitzer, Hans
    Schauwecker, Johannes
    Bader, Rainer
    Mittelmeier, Wolfram
    BIOMEDIZINISCHE TECHNIK, 2010, 55 (05): : 251 - 264
  • [8] Cementless total hip arthroplasty in advanced tuberculosis of the hip
    Zeng, Min
    Hu, Yihe
    Leng, Yi
    Xie, Jie
    Wang, Long
    Li, Mingqing
    Zhu, Jianxi
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (11) : 2103 - 2107
  • [9] Cementless total hip arthroplasty in advanced tuberculosis of the hip
    Min Zeng
    Yihe Hu
    Yi Leng
    Jie Xie
    Long Wang
    Mingqing Li
    Jianxi Zhu
    International Orthopaedics, 2015, 39 : 2103 - 2107
  • [10] Risk factors for intraoperative calcar fracture in cementless total hip arthroplasty
    Miettinen, Simo S. A.
    Makinen, Tatu J.
    Kostensalo, Inari
    Mekela, Keijo
    Huhtala, Heini
    Kettunen, Jukka S.
    Remes, Ville
    ACTA ORTHOPAEDICA, 2016, 87 (02) : 113 - 119