Ground test results of the micro-vibration interference for the x-ray microcalorimeter onboard XRISM

被引:1
|
作者
Hasebe, Takashi [1 ]
Imamura, Ryuta [2 ]
Tsujimoto, Masahiro [3 ]
Awaki, Hisamitsu [2 ]
Chiao, Meng P. [4 ]
Fujimoto, Ryuichi [5 ]
Hartz, Leslie S. [4 ]
Sneiderman, Gary A. [4 ]
Takei, Yoh [6 ]
Yasuda, Susumu [7 ]
机构
[1] Univ Tokyo, Kavli Inst Phys & Math Universe WPI, Chiba, Japan
[2] Ehime Univ, Grad Sch Sci & Engn, Matsuyama, Ehime, Japan
[3] Japan Aerosp Explorat Agcy JAXA, Inst Space & Astronaut Sci, Sagamihara, Kanagawa, Japan
[4] NASA, Goddard Space Flight Ctr, Greenbelt, MD USA
[5] Kanazawa Univ, Fac Math & Phys, Kanazawa, Ishikawa, Japan
[6] Japan Aerosp Explorat Agcy JAXA, Inst Space & Astronaut Sci, Ibaraki, Japan
[7] Japan Aerosp Explorat Agcy JAXA, Ibaraki, Japan
关键词
low temperature detector; x-ray microcalorimeter; micro-vibration interference; XRISM; CRYOCOOLERS; SYSTEM;
D O I
10.1117/12.2629782
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Resolve is a payload hosting an x-ray microcalorimeter detector operated at 50 mK in the X-Ray Imaging and Spectroscopy Mission (XRISM), which is currently under development by an international collaboration and is planned to be launched in 2023. One of the technical concerns is the micro-vibration interference to the sensitive microcalorimeter detector by the spacecraft bus components. We verified this in a series of the ground tests in 2021-2022, the results of which are reported here. We defined the micro-vibration interface between the spacecraft and the Resolve instrument. In the instrument-level test, we tested the flight-model hardware against the interface level by injecting micro-vibration using vibrators and evaluated the instrument response using the 50 mK stage temperature stability, the ADR magnet current consumption rate, and the detector noise spectra. We found the strong responses when injecting micro-vibration at similar to 200, 380, and 610 Hz. In the former two cases, the beat among the injected frequency and the cryocooler frequency harmonics are also observed in the detector noise spectra. In the spacecraft-level test, we measured the acceleration and the instrument responses with and without suspending the entire spacecraft. The reaction wheels and the inertial reference units, two major sources of micro-vibration among the bus components, were operated. We found that the observed Resolve responses are within acceptable levels.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Ground test results of the electromagnetic interference for the x-ray microcalorimeter onboard XRISM
    Kurihara, Miki
    Tsujimoto, Masahiro
    Eckart, Megan E.
    Kilbourne, Caroline A.
    Matsuda, Frederick T.
    McLaughlin, Brian
    Oguri, Shugo
    Porter, Frederick S.
    Takei, Yoh
    Kochibe, Yoichi
    arXiv, 2023,
  • [2] Ground test results of the electromagnetic interference for the x-ray microcalorimeter onboard XRISM
    Kurihara, Miki
    Tsujimoto, Masahiro E.
    Eckart, Megan A.
    Kilbourne, Caroline T.
    Matsuda, Frederick
    McLaughlin, Brian
    Oguri, Shugo S.
    Porter, Frederick
    Takei, Yoh
    Kochibe, Yoichi
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2023, 9 (01) : 18004
  • [3] Ground test results of the electromagnetic interference for the x-ray microcalorimeter onboard XRISM
    Kurihara, Miki
    Tsujimoto, Masahiro
    Eckart, Megan E.
    Kilbourne, Caroline A.
    Matsuda, Frederick T.
    McLaughlin, Brian
    Oguri, Shugo
    Porter, Frederick S.
    Takei, Yoh
    Kochibe, Yoichi
    SPACE TELESCOPES AND INSTRUMENTATION 2022: ULTRAVIOLET TO GAMMA RAY, 2022, 12181
  • [4] Ground test results of the electromagnetic interference for the x-ray microcalorimeter onboard XRISM
    Kurihara, Miki
    Tsujimoto, Masahiro
    Eckart, Megan E.
    Kilbourne, Caroline A.
    Matsuda, Frederick T.
    McLaughlin, Brian
    Oguri, Shugo
    Porter, Frederick S.
    Takei, Yoh
    Kochibe, Yoichi
    Proceedings of SPIE - The International Society for Optical Engineering, 2022, 12181
  • [5] Results of accelerometer monitor in the ground testing of Resolve x-ray microcalorimeter instrument onboard XRISM
    Imamura, Ryuta
    Tsujimoto, Masahiro
    Awaki, Hisamitsu
    Chiao, Meng P.
    Fujimoto, Ryuichi
    Ishisaki, Yoshitaka
    Kelley, Richard L.
    Kilbourne, Caroline A.
    Porter, Frederick S.
    Sawada, Makoto
    Sneiderman, Gary A.
    Takei, Yoh
    Yamada, Shinya
    X-RAY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY X, 2022, 12191
  • [6] Ground test results of the microvibration interference for the x-ray microcalorimeter onboard x-ray imaging and spectroscopy mission
    Hasebe, Takashi
    Imamura, Ryuta
    Tsujimoto, Masahiro
    Awaki, Hisamitsu
    Chiao, Meng
    Fujimoto, Ryuichi
    Hartz, Leslie S.
    Kilbourne, Caroline A.
    Sneiderman, Gary A.
    Takei, Yoh
    Yasuda, Susumu
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2023, 9 (01) : 14003
  • [7] Mechanical Cryocooler Noise Observed in the Ground Testing of the Resolve X-ray Microcalorimeter Onboard XRISM
    Imamura, R.
    Awaki, H.
    Tsujimoto, M.
    Yamada, S.
    Porter, F. S.
    Kilbourne, C. A.
    Kelley, R. L.
    Takei, Y.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2023, 211 (5-6) : 426 - 433
  • [8] Mechanical Cryocooler Noise Observed in the Ground Testing of the Resolve X-ray Microcalorimeter Onboard XRISM
    R. Imamura
    H. Awaki
    M. Tsujimoto
    S. Yamada
    F. S. Porter
    C. A. Kilbourne
    R. L. Kelley
    Y. Takei
    Journal of Low Temperature Physics, 2023, 211 : 426 - 433
  • [9] Relative timing calibration of the Resolve x-ray microcalorimeter onboard XRISM using the modulated x-ray source
    Omama, Tomoki
    Tsujimoto, Masahiro
    Sawada, Makoto
    Kilbourne, Caroline A.
    de Vries, Cor
    Eckart, Megan E.
    Ishisaki, Yoshitaka
    Kitamoto, Shunji
    Leutenegger, Maurice A.
    Porter, Frederick S.
    Wolfs, Rob
    SPACE TELESCOPES AND INSTRUMENTATION 2022: ULTRAVIOLET TO GAMMA RAY, 2022, 12181
  • [10] The X-ray Microcalorimeter Spectrometer onboard of IXO
    den Herder, J. W.
    Kelley, L.
    Mitsuda, K.
    Piro, L.
    Bandler, S. R.
    Bastia, P.
    Boyce, K. R.
    Bruin, M.
    Chervenak, J. A.
    Colasanti, L.
    Doriese, W. B.
    DiPirro, M.
    Eckart, M. E.
    Ezoe, Y.
    Figueroa-Feliciano, E.
    Ferrari, L.
    Fujimoto, R.
    Gatti, F.
    Gendreau, K. C.
    Gottardi, L.
    den Hartog, R.
    Hilton, G. C.
    Hoevers, H.
    Irwin, K. D.
    Ishisaki, Y.
    Kashani, A.
    Kilbourne, C. A.
    de Korte, P.
    van der Kuur, J.
    Macculi, C.
    Mineo, T.
    Nieland, J. H.
    Ohashi, T.
    Paltani, S.
    Perinati, E.
    Porter, F. S.
    Shirron, P. J.
    Smith, S. J.
    Takei, Y.
    Tashiro, M.
    Torrioli, G.
    Tsujimoto, M.
    van Weers, H.
    Yamasaki, N. Y.
    SPACE TELESCOPES AND INSTRUMENTATION 2010: ULTRAVIOLET TO GAMMA RAY, 2010, 7732