Percutaneously inserted central catheter for total parenteral nutrition in neonates: Complications rates related to upper versus lower extremity insertion

被引:81
|
作者
Hoang, Viet [1 ]
Sills, Jack [1 ]
Chandler, Michelle [2 ]
Busalani, Erin [1 ]
Clifton-Koeppel, Robin [1 ]
Modanlou, Houchang D. [1 ]
机构
[1] Univ Calif Irvine, Sch Med, Dept Pediat, Div Neonatal Perinatal Med, Irvine, CA 92717 USA
[2] Univ Calif Irvine, Sch Med, Div Pediat Radiol, Dept Radiol, Irvine, CA 92717 USA
关键词
PICC; CRBSI; septicemia; TPN; cholestasis;
D O I
10.1542/peds.2007-1962
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
OBJECTIVE. The objective of this study was to compare the complication rates of upper versus lower extremity percutaneously inserted central catheters used for total parenteral nutrition in neonates. METHODS. During a 48-month study period, 396 neonates were identified as having had percutaneously inserted central venous catheters. A total of 370 catheters were inserted from the upper and 107 from the lower extremity. Data retrieved and analyzed were birth weight, gestational age, age at placement, duration in place, duration of total parenteral nutrition, type of infusates, catheter-related bloodstream infection, phlebitis, leakage, occlusion, necrotizing enterocolitis, intraventricular hemorrhage, serum creatinine, liver function tests, and length of hospitalization. RESULTS. The median birth weight and gestational age were 940 g and 28 weeks. The rate of catheter-related bloodstream infection was 11.6% for the upper and 9.3% in the lower extremity catheters. The most common organism was coagulase-negative Staphylococcus for both upper and lower extremity catheters and significantly higher with catheters from the upper extremity. Lower extremity catheters were in place longer, and the time from insertion to complication was also longer. The rate of cholestasis was higher for the upper extremity catheters. Multiple regression analysis showed that the most significant contributor to cholestasis was duration of time the catheters were in place and the duration of total parenteral nutrition administration. Receiver operating characteristics curve demonstrated higher sensitivity for duration of catheters in predicting cholestasis with duration of total parenteral nutrition being more specific. CONCLUSION. Lower extremity percutaneously inserted central venous catheters had lower rates of catheter-related bloodstream infection, longer time to first complication, and lower cholestasis despite longer duration of total parenteral nutrition. When possible, lower extremity inserted catheters should be used for the administration of total parenteral nutrition.
引用
收藏
页码:E1152 / E1159
页数:8
相关论文
共 45 条
  • [1] Peripherally Inserted Central Catheter Complications in Neonates With Upper Versus Lower Extremity Insertion Sites
    Wrightson, Della Daugherty
    ADVANCES IN NEONATAL CARE, 2013, 13 (03) : 198 - 204
  • [2] Percutaneously Inserted Central Venous Catheter Tip Position in Preterm Neonates and Complications
    Chhina, Amitoj Singh
    Shenoi, Arvind
    Kumar, R. Kishore
    Patel, Anubhava
    INDIAN PEDIATRICS, 2016, 53 (09) : 838 - 839
  • [3] Catheter-related complications of total parenteral nutrition
    Buchman, Alan L.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2007, 102 : S97 - S101
  • [4] Intraperitoneal infiltration of total parenteral nutrition related to a peripherally inserted central catheter in the saphenous vein
    Valente do Amaral Lopes, Selma Alves
    Queiroz-Filho, Helio
    Pires Bastos, Paulo Marcelo
    Souza, Ariane Sampaio
    Luz, Mariana
    Barreto, Bruna Brandao
    Gusmao-Flores, Dimitri
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2020, 105 (03): : F327 - F327
  • [5] Total parenteral nutrition pleural effusion after peripherally inserted central venous catheter insertion despite fluoroscopic confirmation
    Yang, Michael
    Lopez, Angelena
    SAGE OPEN MEDICAL CASE REPORTS, 2023, 11
  • [6] TOTAL PARENTERAL-NUTRITION USING PERIPHERALLY INSERTED CENTRAL VENOUS CATHETERS IN NEONATES
    LASSALETA, L
    ALONSO, S
    MURCIA, J
    UTRILLA, JG
    INTENSIVE CARE MEDICINE, 1987, 13 (06) : 435 - 435
  • [7] Complication risks associated with lower versus upper extremity peripherally inserted central venous catheters in neonates with gastroschisis
    Ma, Meiyun
    Garingo, Arlene
    Jensen, Aaron R.
    Bliss, David
    Friedlich, Philippe
    JOURNAL OF PEDIATRIC SURGERY, 2015, 50 (04) : 556 - 558
  • [8] AN ANALYSIS OF DIFFERENT TREATMENT STRATEGIES FOR CATHETER-RELATED SEPSIS IN NEONATES WITH PERCUTANEOUSLY INSERTED CENTRAL VENOUS CATHETER: REMOVAL OR NOT?
    Tsai, M. H.
    Huang, Y. -C.
    Lien, R.
    PEDIATRIC RESEARCH, 2010, 68 : 471 - 471
  • [9] Hydromediastinum and hydrothorax as delayed complications of peripherally inserted central catheter used for total parenteral nutrition: A case report Julan
    Chica, Julian
    Ballen, Natalia P.
    Aguillon, Kelly J.
    Rugeles, Saul J.
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2021, 86
  • [10] Peripherally Inserted Central Catheter Tip Malposition in Neonates: A Comparison of Placement in the Head 8r Neck, Upper Extremity, and Lower Extremity
    Sangsari, Razieh
    Mirnia, Kayvan
    Ghassemzadeh, Maral
    Rameshgar, Mahtab
    Saeedi, Maryam
    Bayati, Nasrin
    Emamgholi, Somayeh
    IRANIAN JOURNAL OF PEDIATRICS, 2024, 34 (06)