A Multi-Center Study on Human Brain Glutathione Conformation using Magnetic Resonance Spectroscopy

被引:25
|
作者
Shukla, Deepika [1 ]
Mandal, Pravat K. [1 ,2 ]
Ersland, Lars [3 ,4 ,5 ]
Gruner, Eli Renate [5 ,6 ,7 ]
Tripathi, Manjari [8 ]
Raghunathan, Partha [9 ]
Sharma, Ankita [1 ]
Chaithya, G. R. [1 ]
Punjabi, Khushboo [1 ]
Splaine, Christopher [10 ]
机构
[1] Natl Brain Res Ctr, Neuroimaging & Neurospect Lab NINS, Gurgaon, India
[2] Florey Inst Neurosci & Mental Hlth, Melbourne, Vic, Australia
[3] Haukeland Hosp, Dept Clin Engn, Bergen, Norway
[4] Univ Bergen, Dept Biol & Med Psychol, Bergen, Norway
[5] Univ Oslo, NORMENT Ctr Excellence, Oslo, Norway
[6] Haukeland Hosp, Dept Clin Radiol, Bergen, Norway
[7] Univ Bergen, Dept Phys & Technol, Bergen, Norway
[8] All India Inst Med Sci, Dept Neurol, New Delhi, India
[9] Natl Brain Res Ctr, Neuroimaging Facil, Gurgaon, India
[10] Case Western Reserve Univ, Dept Chem, Cleveland, OH 44106 USA
关键词
Closed and extended conformation; glutathione; MEGA-PRESS MRS; multi-center; OXIDIZED GLUTATHIONE; REDUCED GLUTATHIONE; OXIDATIVE STRESS; AQUEOUS-SOLUTION; QUANTIFICATION; ANTIOXIDANT; CADMIUM; DISEASE; GSH;
D O I
10.3233/JAD-180648
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Molecular dynamics simulation and in vitro nuclear magnetic resonance (NMR) studies on glutathione (GSH) indicated existence of closed and extended conformations. The present work in a multi-center research setting reports indepth analysis of GSH conformers in vivo using a common magnetic resonance spectroscopy (MRS) protocol and signal processing scheme. MEGA-PRESS pulse sequence was applied on healthy subjects using 3T Philips MRI scanner (India) and 3T GE MRI scanner (Norway) using the same experimental parameters (echo time, repetition time, and selective 180 degrees refocusing ON-pulse at 4.40 ppm and 4.56 ppm). All MRS data were processed at one site National Brain Research Center (NBRC) using in-house MRS processing toolbox (KALPANA) for consistency. We have found that both the closed and extended GSH conformations are present in human brain and the relative proportion of individual conformer peak depends on the specific selection of refocusing ON-pulse position in MEGA-PRESS pulse sequence. It is important to emphasize that in vivo experiments with different refocusing and inversion pulse positions, echo time, and voxel size, clearly evidence the presence of both the GSH conformations. The GSH conformer peak positions for the closed GSH (Cys-H-beta) peak at similar to 2.80 ppm and extended GSH (Cys-H-beta) peak at similar to 2.95 ppm remain consistent irrespective of the selective refocusing OFF-pulse positions. This is the first in vivo study where both extended and closed GSH conformers are detected using the MEGA-PRESS sequence employing the parameters derived from the high resolution in vitro NMR studies on GSH.
引用
收藏
页码:517 / 532
页数:16
相关论文
共 50 条
  • [1] Standardized quality metric system for structural brain magnetic resonance images in multi-center neuroimaging study
    Michael E. Osadebey
    Marius Pedersen
    Douglas L. Arnold
    Katrina E. Wendel-Mitoraj
    for the Alzheimer’s Disease Neuroimaging Initiative
    BMC Medical Imaging, 18
  • [2] Standardized quality metric system for structural brain magnetic resonance images in multi-center neuroimaging study
    Osadebey, Michael E.
    Pedersen, Marius
    Arnold, Douglas L.
    Wendel-Mitoraj, Katrina E.
    BMC MEDICAL IMAGING, 2018, 18
  • [3] Glutathione in in the human brain: Review of its roles and measurement by magnetic resonance spectroscopy
    Rae, Caroline D.
    Williams, Stephen R.
    ANALYTICAL BIOCHEMISTRY, 2017, 529 : 127 - 143
  • [4] Subjective Symptoms in Magnetic Resonance Imaging Personnel: A Multi-Center Study in Italy
    Bravo, Giulia
    Modenese, Alberto
    Arcangeli, Giulio
    Bertoldi, Chiara
    Camisa, Vincenzo
    Corona, Gianluca
    Giglioli, Senio
    Ligabue, Guido
    Moccaldi, Roberto
    Mucci, Nicola
    Muscatello, Martina
    Venturelli, Irene
    Vimercati, Luigi
    Zaffina, Salvatore
    Zanotti, Giulio
    Gobba, Fabriziomaria
    FRONTIERS IN PUBLIC HEALTH, 2021, 9
  • [5] Magnetic resonance spectroscopy of the human brain
    Barker, P
    MOLECULAR AND CHEMICAL NEUROPATHOLOGY, 1996, 27 (01) : 42 - 44
  • [6] Magnetic resonance spectroscopy of the human brain
    Ross, B
    Bluml, S
    ANATOMICAL RECORD, 2001, 265 (02): : 54 - 84
  • [7] Magnetic resonance spectroscopy of the human brain
    Strozik-Kotlorz, D.
    PHYSICS OF PARTICLES AND NUCLEI, 2014, 45 (01) : 347 - 348
  • [8] Magnetic resonance spectroscopy of the human brain
    D. Strózik-Kotlorz
    Physics of Particles and Nuclei, 2014, 45 : 347 - 348
  • [9] Robustness of radiomic features in magnetic resonance imaging for patients with glioblastoma: Multi-center study
    Saltybaeva, Natalia
    Tanadini-Lang, Stephanie
    Vuong, Diem
    Burgermeister, Simon
    Mayinger, Michael
    Bink, Andrea
    Andratschke, Nicolaus
    Guckenberger, Matthias
    Bogowicz, Marta
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 22 : 131 - 136
  • [10] Magnetic resonance spectroscopy of neurotransmitters in human brain
    Novotny, EJ
    Fulbright, RK
    Pearl, PL
    Gibson, KM
    Rothman, DL
    ANNALS OF NEUROLOGY, 2003, 54 : S25 - S31