Fault Ride Through of DFIG Wind Turbines during symmetrical voltage dip with Crowbar or Stator Current Feedback Solution

被引:22
|
作者
Wessels, Christian [1 ]
Fuchs, Friedrich W. [1 ]
机构
[1] Christian Albrechts Univ Kiel, Inst Power Elect & Elect Drives, Kaiserstr 2, D-24143 Kiel, Germany
来源
2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION | 2010年
关键词
FED INDUCTION GENERATOR; CONVERTERS; SYSTEMS;
D O I
10.1109/ECCE.2010.5618076
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Low Voltage Ride Through is an important feature for wind turbine systems to fulfill grid code requirements. In case of wind turbine technologies using doubly fed induction generators the reaction to grid voltage disturbances is sensitive. Hardware or software protection must be implemented to protect the converter from tripping during severe grid voltage faults. In this paper two methods for low voltage ride through of symmetrical grid voltage dips are investigated. As a basis, an analysis of the rotor voltages during grid fault is given. First, the conventional hardware method using a crowbar is introduced. Then the stator current reference feedback solution is presented. Both methods are investigated and compared by simulation results using 2 MW wind turbine system parameters. Measurement results on a 22 kW laboratory DFIG test bench show the effectiveness of the proposed control technique.
引用
收藏
页码:2771 / 2777
页数:7
相关论文
共 50 条
  • [1] Improvement of the Availabiliy of the DFIG Wind Turbines during Voltage DIP with Crowbar Circuit
    Drhorhi, Ismail
    Lahda, Mohamed
    Mimet, Abdelaziz
    2014 INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC), 2014, : 846 - 850
  • [2] Cost Effective Method for DFIG Fault Ride-through During Symmetrical Voltage Dip
    Gong, B.
    Xu, D.
    Wu, B.
    IECON 2010 - 36TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2010,
  • [3] Improved Crowbar Control Strategy of DFIG Based Wind Turbines for Grid Fault Ride-Through
    Peng, Ling
    Francois, Bruno
    Li, Yongdong
    APEC: 2009 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1- 4, 2009, : 1932 - +
  • [4] Active Damping Control of DFIG Wind Turbines during Fault Ride Through
    Xu, Hao
    Xu, Honghua
    Chen, Liang
    Wenske, Jan
    2013 3RD INTERNATIONAL CONFERENCE ON ELECTRIC POWER AND ENERGY CONVERSION SYSTEMS (EPECS), 2013,
  • [5] Fault ride-through capability of DFIG wind turbines
    Hansen, Anca D.
    Michalke, Gabriele
    RENEWABLE ENERGY, 2007, 32 (09) : 1594 - 1610
  • [6] Characteristics Analysis to DFIG-based Wind Turbine's Stator Current During Crowbar Protection and Symmetrical Fault by Operational Inductance
    Chang Y.
    Hu J.
    Tian X.
    Zhang X.
    Kong X.
    Yuan Y.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (21): : 6192 - 6199
  • [7] Study of fault ride-through for DFIG based wind turbines
    Bing, X
    Fox, B
    Flynn, D
    PROCEEDINGS OF THE 2004 IEEE INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION, RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1 AND 2, 2004, : 411 - 416
  • [8] High Voltage Ride Through with FACTS for DFIG Based Wind Turbines
    Wessels, C.
    Fuchs, F. W.
    EPE: 2009 13TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-9, 2009, : 1014 - 1023
  • [9] Low Voltage Ride Through in DFIG Based Wind Turbines: A Review
    Baiju, P.
    Rajeev, T.
    2015 INTERNATIONAL CONFERENCE ON CONTROL COMMUNICATION & COMPUTING INDIA (ICCC), 2015, : 337 - 342
  • [10] Influence of Crowbar and Chopper Protection on DFIG during Low Voltage Ride Through
    Monteiro Pereira, Rita M.
    Pereira, Adelino J. C.
    Ferreira, Carlos Machado
    Maciel Barbosa, Fernando P.
    ENERGIES, 2018, 11 (04)