Effect of cardiopulmonary resuscitation on intubation using a Macintosh laryngoscope, the Air Way Scope, and the gum elastic bougie: A manikin study

被引:22
|
作者
Maruyama, K. [1 ]
Tsukamoto, S. [1 ]
Ohno, S. [1 ]
Kobayashi, K. [1 ]
Nakagawa, H. [1 ]
Kitamura, A. [1 ]
Hayashida, M. [1 ]
机构
[1] Saitama Med Univ, Int Med Ctr, Dept Anesthesiol, Hidaka, Saitama 3501241, Japan
关键词
Cardiopulmonary resuscitation; Airway; Intubation; AirWay Scope; Macintosh laryngoscope; Gum elastic bougie; SIMULATED DIFFICULT INTUBATION; TRACHEAL INTUBATION; VIDEO LARYNGOSCOPE;
D O I
10.1016/j.resuscitation.2010.03.041
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Physicians could encounter difficult intubation during cardiopulmonary resuscitation (CPR) in trauma patients due to the patient's movement from continuous chest compression and to cervical stabilisation. Therefore, first, we evaluated the impact of chest compression with or without cervical stabilisation on intubation with a Macintosh laryngoscope. Next, we compared difficulty in intubation among the Macintosh laryngoscope, AirWay Scope (AWS), and gum elastic bougie (GEB) with the Macintosh laryngoscope in three simulated CPR scenarios in a randomised, controlled, cross-over study design. Methods: Twenty-three anaesthetists intubated the trachea of a manikin (ALS Skill Master, Laerdal Medical Japan, Tokyo, Japan) using the Macintosh laryngoscope, AWS, and GEB in the, control scenario, chest compression scenario, and chest compression with cervical stabilisation scenario. Difficulty in intubation was rated on a 5-point scale and the intubation time was measured. Results: Continuous chest compression increased difficulty in intubation with the Macintosh laryngoscope, compared with the control scenario. Concurrent application of cervical stabilisation further increased the difficulty, compared with application of chest compression alone. Of the three devices compared, the AWS facilitated the easiest intubation, and the GEB facilitated the second-easiest intubation in all scenarios, though the intubation time was slightly longer with the GEB than with other devices. Conclusion: CPR employing continuous chest compression with or without cervical stabilisation caused difficult intubation with the Macintosh laryngoscope. The AWS and GEB facilitated the easiest and second-easiest intubation, respectively, even during CPR employing continuous chest compression with or without cervical stabilisation in a manikin. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1014 / 1018
页数:5
相关论文
共 33 条
  • [1] Comparison of tracheal intubation using the Macintosh laryngoscope, Air Way Scope and gum elastic bougie under chest compression and cervical stabilisation
    Xue, F. S.
    Xiong, J.
    Wang, Q.
    Yuan, Y. J.
    Liao, X.
    RESUSCITATION, 2010, 81 (11) : 1593 - 1593
  • [2] Airway Scope and gum elastic bougie with Macintosh laryngoscope for tracheal intubation in patients with simulated restricted neck mobility
    Komatsu, R.
    Kamata, K.
    Hoshi, I.
    Sessler, D. I.
    Ozaki, M.
    BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (06) : 863 - 869
  • [3] Comparison of Tracheal Intubation Using Airway Scope and Macintosh Laryngoscope in Manikin Study
    Xue, Fu S.
    Xiong, Jun
    Wang, Qiang
    Yuan, Yu J.
    Liao, Xu
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 69 (04): : 1007 - 1008
  • [4] Randomized comparison of the airway scope and the macintosh laryngoscope for the tracheal intubation in manikin study
    Yuasa, Haruyuki
    Yokoyama, Hiroyuki
    Yonemoto, Naohiro
    Kada, Akiko
    Kasahara, Yoichiro
    Koga, Yoshihisa
    Nonogi, Hiroshi
    CIRCULATION, 2007, 116 (16) : 944 - 944
  • [5] Performance of a Pentax-Airway scope and a Macintosh laryngoscope for difficult intubation in a manikin study
    Xue, F. S.
    Liao, X.
    Yuan, Y. J.
    Liu, J. H.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (07) : 900 - 901
  • [6] Comparison of the Airway Scope®, gum elastic bougie and fibreoptic bronchoscope in simulated difficult tracheal intubation:: a manikin study
    Koyama, Y.
    Inagawa, G.
    Miyashita, T.
    Kikuchi, T.
    Miura, N.
    Miki, T.
    Kurihara, R.
    Kamiya, Y.
    Goto, T.
    ANAESTHESIA, 2007, 62 (09) : 936 - 939
  • [7] Performance of a Pentax-Airway scope and a Macintosh laryngoscope for difficult intubation in a manikin study Reply
    Kariya, T.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (07) : 901 - 901
  • [8] Tracheal Intubation of a Difficult Airway Using Airway Scope, Airtraq, and Macintosh Laryngoscope: A Comparative Manikin Study of Inexperienced Personnel
    Liu, Liangji
    Tanigawa, Koichi
    Kusunoki, Shinji
    Tamura, Tomoko
    Ota, Kohei
    Yamaga, Satoshi
    Kida, Yoshiko
    Otani, Tadatsugu
    Sadamori, Takuma
    Takeda, Taku
    Iwasaki, Yasumasa
    Hirohashi, Nobuyuki
    ANESTHESIA AND ANALGESIA, 2010, 110 (04): : 1049 - 1055
  • [9] A novel technique using the gum elastic bougie and video laryngoscope for intubation in an unanticipated difficult airway
    Hand, William R.
    Sutton, Brandon M.
    JOURNAL OF CLINICAL ANESTHESIA, 2012, 24 (08) : 675 - 677
  • [10] Nasotracheal intubation using the Airway Scope with the gum elastic bougie and modified guideless blade
    Tagawa, Tsuyoshi
    Okuda, Masahiro
    Sakuraba, Shigeki
    JOURNAL OF CLINICAL ANESTHESIA, 2010, 22 (01) : 73 - 74