Nerve cuff electrode using embedded magnets and its application to hypoglossal nerve stimulation

被引:8
|
作者
Seo, Jungmin [1 ]
Wee, Jee Hye [2 ]
Park, Jeong Hoan [1 ]
Park, Pona [2 ]
Kim, Jeong-Whun [2 ]
Kim, Sung June [1 ]
机构
[1] Seoul Natl Univ, Dept Elect & Comp Engn, Seoul 151744, South Korea
[2] Seoul Natl Univ Hosp, Coll Med, Dept Otorhinolaryngol, Songnam 13620, South Korea
基金
新加坡国家研究基金会;
关键词
cuff electrode; magnet; hypoglossal nerve; liquid crystal polymer; MEMS; neural engineering; magnetic field; OBSTRUCTIVE SLEEP-APNEA; CRYSTAL POLYMER LCP; COMPRESSION;
D O I
10.1088/1741-2560/13/6/066014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. A novel nerve cuff electrode with embedded magnets was fabricated and developed. In this study, a pair of magnets was fully embedded and encapsulated in a liquid crystal polymer (LCP) substrate to utilize magnetic force in order to replace the conventional installing techniques of cuff electrodes. In vitro and in vivo experiments were conducted to evaluate the feasibility of the magnet-embedded nerve cuff electrode (MENCE). Lastly, several issues pertaining to the MENCE such as the cuff-to-nerve diameter ratio, the force of the magnets, and possible concerns were discussed in the discussion section. Approach. Electrochemical impedance spectrum and cyclic voltammetry assessments were conducted to measure the impedance and charge storage capacity of the cathodal phase (CSCc). The MENCE was installed onto the hypoglossal nerve (HN) of a rabbit and the movement of the genioglossus was recorded through C-arm fluoroscopy while the HN was stimulated by a pulsed current. Main results. The measured impedance was 0.638 angle -67.8 degrees k Omega at 1 kHz and 5.27 angle -82.1 degrees k Omega at 100 Hz. The average values of access resistance and cut-off frequency were 0.145 k Omega and 3.98 kHz, respectively. The CSCc of the electrode was measured as 1.69 mC cm(-2) at the scan rate of 1mV s(-1). The movement of the genioglossus contraction was observed under a pulsed current with an amplitude level of 0.106 mA, a rate of 0.635 kHz, and a duration of 0.375 ms applied through the MENCE. Significance. A few methods to close and secure cuff electrodes have been researched, but they are associated with several drawbacks. To overcome these, we used magnetic force as a closing method of the cuff electrode. The MENCE can be precisely installed on a target nerve without any surgical techniques such as suturing or molding. Furthermore, it is convenient to remove the installed MENCE because it requires little force to detach one magnet from the other, enabling repeatable installation and removal. We anticipate that the MENCE will become a very useful tool given its unique properties as a cuff electrode for neural engineering.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Selective fascicular recording of the hypoglossal nerve using a multicontact nerve cuff electrode
    Yoo, PB
    Durand, DM
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 2172 - 2175
  • [2] Selective stimulation of the canine hypoglossal nerve using a multi-contact cuff electrode
    Yoo, PB
    Sahin, M
    Durand, DM
    ANNALS OF BIOMEDICAL ENGINEERING, 2004, 32 (04) : 511 - 519
  • [3] Selective Stimulation of the Canine Hypoglossal Nerve Using a Multi-contact Cuff Electrode
    Paul B. Yoo
    Mesut Sahin
    Dominique M. Durand
    Annals of Biomedical Engineering, 2004, 32 : 511 - 519
  • [4] Selective stimulation of the hypoglossal nerve with a multi-contact cuff electrode
    Yoo, PB
    Durand, DM
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 1309 - 1312
  • [5] A SPIRAL NERVE CUFF ELECTRODE FOR PERIPHERAL-NERVE STIMULATION
    NAPLES, GG
    MORTIMER, JT
    SCHEINER, A
    SWEENEY, JD
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (11) : 905 - 916
  • [6] A SPIRAL NERVE CUFF ELECTRODE FOR PERIPHERAL-NERVE STIMULATION - COMMENT
    RACZ, GB
    HEAVNER, JE
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (11) : 1140 - 1140
  • [7] A SPIRAL NERVE CUFF ELECTRODE FOR PERIPHERAL-NERVE STIMULATION - REPLY
    NAPLES, GG
    MORTIMER, JT
    SCHEINER, A
    SWEENEY, JD
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (11) : 1140 - 1141
  • [8] Human nerve stimulation thresholds and selectivity using a multi-contact nerve cuff electrode
    Polasek, Katharine H.
    Hoyen, Harry A.
    Keith, Michael W.
    Tyler, Dustin J.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2007, 15 (01) : 76 - 82
  • [9] Hypoglossal Nerve (Cranial Nerve XII) Stimulation
    Yu, Jason L.
    Thaler, Erica R.
    OTOLARYNGOLOGIC CLINICS OF NORTH AMERICA, 2020, 53 (01) : 157 - +
  • [10] Insomnia and Hypoglossal Nerve Stimulation
    Dabboussi, Tarek
    Manchanda, Shalini
    Parker, Noah P.
    Chernyak, Yelena
    Stahl, Stephanie M.
    CURRENT SLEEP MEDICINE REPORTS, 2023, 9 (03) : 190 - 196