Normalizing PPG Signals to the AC Component - Applications for Monitoring Volume Loss

被引:0
|
作者
Silverman, David G. [1 ]
Liang, I-Hsun [1 ,2 ]
Alian, Aymen [1 ]
Shelley, Kirk [1 ]
Stachenfeld, Nina [3 ]
机构
[1] Yale Univ, Sch Med, Dept Anesthesiol, New Haven, CT 06520 USA
[2] St Barnabas Hosp, Dept Anesthesiol, Livingston, NJ USA
[3] Yale Univ, Sch Med, John B Pierce Lab Physiol, New Haven, CT 06520 USA
来源
ANESTHESIA AND ANALGESIA | 2016年 / 122卷
关键词
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
引用
收藏
页数:1
相关论文
共 50 条
  • [1] Optimizing Measurement of the AC Component (Height) of the Photoplethymorgraphic (PPG) Signal
    Nie, Siqin
    Liang, I-Hsun
    Dai, Feng
    Florio, Nick
    Bing, Vicki
    Shelley, Kirk H.
    Alian, Aymen
    Silverman, David G.
    ANESTHESIA AND ANALGESIA, 2014, 119
  • [2] Monitoring Atrial Fibrillation Using PPG Signals and a Smartphone
    Estrella-Gallego, A.
    Vazquez-Briseno, M.
    Nieto-Hipolito, J., I
    Gutierrez-Lopez, E.
    Sanchez-Lopez, J. D.
    Garcia-Berumen, A.
    Rivera-Rodriguez, R.
    INTERNATIONAL JOURNAL OF ONLINE AND BIOMEDICAL ENGINEERING, 2020, 16 (03) : 60 - 74
  • [3] Sleep Monitoring with Intraorally Measured Photoplethysmography (PPG) Signals
    Nabavi, Seyedfakhreddin
    Cogan, John
    Roy, Asim
    Canfield, Brandon
    Kibler, Robert
    Emerick, Collin
    2022 IEEE SENSORS, 2022,
  • [4] ECG and PPG Signals Monitoring by Using Web Audio API
    Stojanovic, Radovan
    Djurkovic, Jovan
    Skraba, Andrej
    2024 13TH MEDITERRANEAN CONFERENCE ON EMBEDDED COMPUTING, MECO 2024, 2024, : 420 - 425
  • [5] Ubiquitous Blood Pressure Monitoring Using EEG and PPG Signals
    Lu, Ying
    Peng, Heng
    Zhao, Jiwei
    Deng, Ziming
    Huang, Zijian
    Zhang, Jinchuan
    Deng, Jian
    Wang, Zhiyong
    Wei, Chuanmin
    PROCEEDINGS OF THE 2017 ACM INTERNATIONAL JOINT CONFERENCE ON PERVASIVE AND UBIQUITOUS COMPUTING AND PROCEEDINGS OF THE 2017 ACM INTERNATIONAL SYMPOSIUM ON WEARABLE COMPUTERS (UBICOMP/ISWC '17 ADJUNCT), 2017, : 257 - 260
  • [6] Monitoring The Early Physiological Effects of Fitness Regimes Using PPG Signals
    Ramakrishnan, Ramesh Kumar
    Gavas, Rahul
    Viraraghavan, Venkata Subramaninan
    Hissaria, Lalit Kumar
    Pal, Arpan
    Balamurandhar, P.
    2020 IEEE INTERNATIONAL CONFERENCE ON PERVASIVE COMPUTING AND COMMUNICATIONS WORKSHOPS (PERCOM WORKSHOPS), 2020,
  • [7] Advances in Cuffless Continuous Blood Pressure Monitoring Technology Based on PPG Signals
    Qin, Caijie
    Wang, Xiaohua
    Xu, Guangjun
    Ma, Xibo
    BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [8] Proposal of a PPG Transducer for Monitoring Vital Signals of Patients in Cardiopulmonary Rehabilitation Programs
    Schwarz, L.
    Paim, F. C. A.
    Sovierzoski, M. A.
    Marino Neto, J.
    Marques, J. L. B.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 834 - 837
  • [9] AC loss density component in electrical steel sheets
    Chwastek, Krzysztof
    PHILOSOPHICAL MAGAZINE LETTERS, 2010, 90 (11) : 809 - 817
  • [10] A Novel Mapping of ECG and PPG to Ensure the Safety of Health Monitoring Applications
    Panda, Abhinandan
    Pinisetty, Srinivas
    Roop, Partha
    IEEE EMBEDDED SYSTEMS LETTERS, 2023, 15 (01) : 49 - 52