A Graphical Tool to Estimate the Air Change Efficiency in Rooms with Heat Recovery Systems

被引:7
|
作者
Meiss, Alberto [1 ]
Angel Padilla-Marcos, Miguel [1 ]
Poza-Casado, Irene [1 ]
Alvaro-Tordesillas, Antonio [1 ]
机构
[1] Univ Valladolid, ETS Arquitectura, Valladolid 47014, Spain
关键词
ventilation; tracer gases; CFD; IAQ; design strategy; VENTILATION EFFICIENCY; FLOW; AGE;
D O I
10.3390/su12031031
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Indoor air quality in buildings must be guaranteed for the health and comfort of the occupants. In order to assess the ventilation strategy of a considered room, the parameter of the air change efficiency (epsilon(a)) can be used. The objective of this work is to provide designers with a graphical tool for a reliable estimate of the value of epsilon(a) of a room. The temperature gradient between the outdoor air supply and the indoor air is so low that the ventilation flow can be assumed as isothermal when high-efficiency heat recovery systems are used. By means of charts, the optimal location of the openings for a better epsilon(a) can be determined during the design process, in order to subsequently apply them. It is concluded that it is very important to consider the epsilon(a) in the case of openings located in facing walls given that its range varies between 40% and 65%. In contrast, its use can be obviated in the case of openings located in non-facing walls, as the value of epsilon(a) obtained is close to 50%; this means a perfect mixing air flow pattern, which is the reference value for the estimation of the indoor air quality (IAQ) in the different national regulations.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Heat recovery system of exhaust air in guest rooms
    Cheng, J.N.
    Nuantong Kongtiao/HV & AC, 2001, 31 (02):
  • [2] Research to estimate energy efficiency of a ventilation and air conditioning heat pump system inside a production premise with ventilation air recovery
    Bezrodny, Myhailo Kostiantynovych
    Misiura, Tymofii Oleksiyovych
    ARCHIVES OF THERMODYNAMICS, 2021, 42 (04) : 69 - 86
  • [3] The Analysis of Heat Recovery Efficiency and Influencing Factors in Air System
    Wang, Chuang
    Li, Rui
    ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 1257 - 1261
  • [4] AIR-TO-AIR HEAT-RECOVERY SYSTEMS FOR RESEARCH LABORATORIES
    CARNES, L
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1984, 26 (05): : 56 - 56
  • [5] Energy efficiency and recovery of heat lost in the Industrial Systems
    Mounkid, S.
    Loukili, A.
    XII MAGHREB DAYS OF MATERIAL SCIENCES, 2017, 186
  • [6] A study of secondary heat recovery efficiency of a heat pipe heat exchanger air conditioning system
    Wang, Haitao
    Zhou, Shunbao
    Wei, Zhongshi
    Wang, Ren
    ENERGY AND BUILDINGS, 2016, 133 : 206 - 216
  • [7] Impact of Intake and Exhaust Ducts on the Recovery Efficiency of Heat Recovery Ventilation Systems
    Marsik, Tom
    Bickford, Riley
    Dennehy, Conor
    Garber-Slaght, Robbin
    Kasper, Jeremy
    ENERGIES, 2021, 14 (02)
  • [8] TEMPERATURE EFFICIENCY OF ROTARY HEAT RECOVERY UNITS IN VENTILATION AND AIR CONDITIONING
    Parfentyeva, Natalia
    Samarin, Oleg
    Lushin, Kirill
    Paulauskaite, Sabina
    Valancius, Kestutis
    ENVIRONMENTAL ENGINEERING, VOLS 1-3, 2011, : 799 - +
  • [9] Analysis and design of an air to air heat exchanger used in energy recovery systems
    Elmacioǧlu H.U.
    Özsevgin I.
    Kocabiyik C.
    Čam N.Y.
    Bilir L.
    Journal of Energy Systems, 2022, 6 (01): : 108 - 130
  • [10] Analysis of the efficiency of air-to-air heat exchanger with a periodic change in the flow direction
    Nizovtsev, M. I.
    Borodulin, V. Yu
    Letushko, V. N.
    Zakharov, A. A.