Pilot study on renal magnetic resonance diffusion tensor imaging: are quantitative diffusion tensor imaging values useful in the evaluation of children with ureteropelvic junction obstruction?

被引:8
|
作者
Delgado, Jorge [1 ]
Berman, Jeffrey I. [1 ,2 ]
Maya, Carolina [1 ]
Carson, Robert H. [1 ]
Back, Susan J. [1 ,2 ]
Darge, Kassa [1 ,2 ]
机构
[1] Childrens Hosp Philadelphia, Dept Radiol, 3401 Civ Ctr Blvd, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Radiol, Perelman Sch Med, Philadelphia, PA 19104 USA
关键词
Children; Diffusion tensor imaging; Magnetic resonance imaging; Magnetic resonance urography; Ureteropelvic junction obstruction; Urinary tract; MR UROGRAPHY; FUNCTIONAL ASSESSMENT; KIDNEY; HYDRONEPHROSIS; FEASIBILITY; ULTRASOUND; VESSELS;
D O I
10.1007/s00247-018-4268-8
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
BackgroundUreteropelvic junction (UPJ) obstruction is a common cause of renal injury in children. Indications for surgery are still controversial. Currently, there is no threshold to differentiate patients with suspected UPJ obstruction requiring surgery from the ones that do not, or to predict renal outcome after surgery. Several studies have demonstrated that diffusion tensor imaging (DTI) results may correlate with microstructural changes in the kidneys.ObjectiveTo evaluate the feasibility of using DTI to identify UPJ obstruction kidneys.Materials and methodsWe analyzed functional MR urography (fMRU) with renal DTI (b=0 and b=400, 20 directions, 1.5Tesla, no respiratory triggering) in 26 kidneys of 19 children (mean age: 6.15years) by comparing 13 kidneys with UPJ obstruction configuration that underwent pyeloplasty following the fMRU, and 13 anatomically normal age- and gender-matched kidneys. DTI tractography was reconstructed using a fractional anisotropy threshold of 0.10 and an angle threshold of 55 degrees. User-defined regions of interest (ROIs) of the renal parenchyma (excluding collecting system) were drawn to quantify DTI parameters: fractional anisotropy, apparent diffusion coefficient (ADC), track length and track volume. The failure rate was evaluated.ResultsAll DTI parameters changed with age; fractional anisotropy decreased (P<0.032). Track volume and track length increased (P<0.05). ADC increased with age in normal kidneys (P<0.001) but not in UPJ obstruction kidneys (P=0.11). After controlling for age, the fractional anisotropy (UPJ obstruction mean: 0.18, normal kidney mean: 0.21; P=0.001) and track length (UPJ obstruction mean: 11.9mm, normal kidney mean: 15.4mm; P<0.001) were lower in UPJ obstruction vs. normal kidneys. There was a trend toward a higher ADC in UPJ obstruction kidneys vs. normal kidneys (P=0.062). The failure rate in UPJ obstruction kidneys due to technical limitations of DTI was 13/26 (50%).ConclusionWe demonstrated that fractional anisotropy is lower in UPJ obstruction than in normal kidneys. It is necessary to improve this technique to increase the success rate and to perform more studies to evaluate if a decrease in fractional anisotropy can differentiate UPJ obstruction kidneys from hydronephrotic kidneys without UPJ obstruction.
引用
收藏
页码:175 / 186
页数:12
相关论文
共 50 条
  • [1] Pilot study on renal magnetic resonance diffusion tensor imaging: are quantitative diffusion tensor imaging values useful in the evaluation of children with ureteropelvic junction obstruction?
    Jorge Delgado
    Jeffrey I. Berman
    Carolina Maya
    Robert H. Carson
    Susan J. Back
    Kassa Darge
    Pediatric Radiology, 2019, 49 : 175 - 186
  • [2] Diffusion tensor magnetic resonance imaging of the breast: a pilot study
    Baltzer, Pascal A. T.
    Schaefer, Anja
    Dietzel, Matthias
    Graessel, David
    Gajda, Mieczyslaw
    Camara, Oumar
    Kaiser, Werner A.
    EUROPEAN RADIOLOGY, 2011, 21 (01) : 1 - 10
  • [3] Diffusion tensor magnetic resonance imaging of the breast: a pilot study
    Pascal A. T. Baltzer
    Anja Schäfer
    Matthias Dietzel
    David Grässel
    Mieczyslaw Gajda
    Oumar Camara
    Werner A. Kaiser
    European Radiology, 2011, 21 : 1 - 10
  • [4] Diffusion Tensor Imaging of a Median Nerve by Magnetic Resonance: A Pilot Study
    Awais, Kanza
    Snoj, Ziga
    Cvetko, Erika
    Sersa, Igor
    LIFE-BASEL, 2022, 12 (05):
  • [5] Diffusion tensor magnetic resonance imaging
    Gulani, V
    Sundgren, PC
    JOURNAL OF NEURO-OPHTHALMOLOGY, 2006, 26 (01) : 51 - 60
  • [6] Diffusion tensor magnetic resonance imaging
    Herrnberger, B
    NERVENHEILKUNDE, 2004, 23 (01) : 50 - 59
  • [7] The role of kidney diffusion tensor magnetic resonance imaging in children
    Ozkan, Mehmet Burak
    Marterer, Robert
    Tscheuner, Sebastian
    Yildirim, Utku Mahir
    Ozkan, Elif
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2016, 47 (04): : 1599 - 1611
  • [8] Magnetic resonance diffusion tensor imaging for evaluation of diabetic polyneuropathy
    Vaeggemose, M.
    Pham, M.
    Ringgaard, S.
    Tankisi, H.
    Ejskjaer, N.
    Poulsen, P.
    Andersen, H.
    EUROPEAN JOURNAL OF NEUROLOGY, 2016, 23 : 83 - 83
  • [9] Diffusion Tensor Magnetic Resonance Imaging of the Pancreas
    Nissan, Noam
    Golan, Talia
    Furman-Haran, Edna
    Apter, Sara
    Inbar, Yael
    Ariche, Arie
    Bar-Zakay, Barak
    Goldes, Yuri
    Schvimer, Michael
    Grobgeld, Dov
    Degani, Hadassa
    PLOS ONE, 2014, 9 (12):
  • [10] Magnetic resonance tractography with diffusion tensor imaging
    Zhou, XJ
    Leeds, NE
    Karmonik, C