Control of occupational exposure to phenol in industrial wastewater treatment plant of a petroleum refinery in Alexandria, Egypt: An intervention application case study

被引:3
|
作者
Zaki, Gehan R. [1 ]
El-Marakby, Fadia A. [1 ]
Ramadan, Alaa El-Din K. [2 ]
Issa, Ahmed I. [1 ]
Nofal, Faten H. [1 ]
机构
[1] Univ Alexandria, Occupat Hlth & Air Pollut Dept, High Inst Publ Hlth HIPH, 165 El Horreya Ave, Alexandria, Egypt
[2] Egyptian Projects Operat & Maintenance EPROM, Alexandria, Egypt
关键词
Bacterial treatment; charcoal treatment; petroleum refinery; phenol exposure; phenolic compounds; pseudomonas aeruginosa; REMOVAL;
D O I
10.1080/15459624.2016.1200193
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Phenol exposure is one of the hazards in the industrial wastewater treatment basin any refinery, additively interacts with hydrogen sulfide emitted from the wastewater basin. Consequently, its concentration should be greatly lower than its threshold limit value, The present study aimed at con oiling occupational exposure to phenol in the work environment of wastewater treatment plant in a refinery by reducing phenolic compounds in the industrial wastewater basin. This study was conducted on both laboratory and refinery scales. The first was completed by dividing each wastewater from the outlets of different refinery units into three portions; the first was analyzed for phenolic compounds.. The second and third were for laboratory scale charcoal and bacterial treatments. The two methods were compared regarding their simplicities, design, and removal efficiencies. Accordingly, bacterial treatment by continuous flow of sewage water containing Pseudomonas Aeruginosa was used for refinery scale treatment. Laboratory scale treatment of phenolic compounds revealed higher removal efficiency of charcoal [100,0(0,0) %] than of bacteria [99,9(0.013)%], The refinery scale bacterial treatment was [99.8(0 013) %] efficient Consequently, level of phenol in the work environment after refinery-scale treatment [0,069(0.802) mg/m(3)] was much lower than that before [5.700(26.050) mg/m(3)], with removal efficiency of [99,125(2.335) %]. From the present study, we can conclude that bacterial treatment of phenolic compounds in industrial wastewater of the wastewater treatment plant using continuous flow Of sewage water containing Pseudomonas Aeruginosa reduces he workers exposure to phenol.
引用
收藏
页码:D208 / D214
页数:7
相关论文
共 43 条
  • [1] Automation of a petroleum refinery wastewater treatment plant. A case study
    Shantz, Robert J.
    Erickson, Virginia B.
    Water pollution research journal of Canada, 1989, 24 (03): : 451 - 462
  • [2] Case study of occupational mercury exposure during decontamination of turnaround in refinery plant
    Muadchim, Maytiya
    Phanprasit, Wantanee
    Robson, Mark Gregory
    Sujirarat, Dusit
    Detchaipitak, Rawee
    INTERNATIONAL JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2017, 23 (01) : 81 - 86
  • [3] Diagnosis of Treatment Efficiency in Industrial Wastewater Treatment Plants: A Case Study at a Refinery ETP
    Kapley, Atya
    Purohit, Hemant J.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (10) : 3789 - 3795
  • [4] Performance evaluation of the main units of a refinery wastewater treatment plant - A case study
    Santos, Carlos E.
    Fonseca, Andre
    Kumar, Eva
    Bhatnagar, Amit
    Vilar, Vitor J. P.
    Botelho, Cidalia M. S.
    Boaventura, Rui A. R.
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2015, 3 (03) : 2095 - 2103
  • [5] In-plant control for water minimization and wastewater reuse: a case study in pasta plants of Alexandria Flour Mills and Bakeries Company, Egypt
    Abd El-Salam, Magda Magdy
    El-Naggar, Hesham Mahmoud
    JOURNAL OF CLEANER PRODUCTION, 2010, 18 (14) : 1403 - 1412
  • [6] Practical application of a hybrid event-based control of an industrial wastewater treatment plant
    Stoecker, Christian
    Roth, Matthias
    AT-AUTOMATISIERUNGSTECHNIK, 2017, 65 (04) : 270 - 279
  • [7] Simulation Analysis of Capacity and Performance Improvement in Wastewater Treatment Plants: Case Study of Alexandria Eastern Plant
    Moursy, Aly
    Sorour, Mohamed T.
    Moustafa, Medhat
    Elbarqi, Walid
    Fayd, Mai
    Elreedy, Ahmed
    TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY, 2018, 1968
  • [8] Simulation of the influence of industrial wastewater on a municipal sewage treatment plant—a case study
    Ákos Rédey
    Viola Somogyi
    József Ányos
    Endre Domokos
    Péter Thury
    Tatiana Yuzhakova
    Environmental Science and Pollution Research, 2011, 18 : 192 - 198
  • [9] Application of photocatalytic procedure combined with zonation for treatment of industrial wastewater - a case study
    Otto Horvath
    Erzsebet Szabo-Bardos
    Zoltan Zsilak
    Gyula Bajnoczi
    PERIODICA POLYTECHNICA-CHEMICAL ENGINEERING, 2012, 56 (02) : 49 - 54
  • [10] Simulation of the influence of industrial wastewater on a municipal sewage treatment plant-a case study
    Redey, Akos
    Somogyi, Viola
    Anyos, Jozsef
    Domokos, Endre
    Thury, Peter
    Yuzhakova, Tatiana
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2011, 18 (02) : 192 - 198