Dual-label time-resolved fluoroimmunoassay for simultaneous measurement of human epidermal growth factor receptor 2 and human epididymis protein 4 in serum

被引:3
|
作者
Zhang, Yi [1 ]
Wang, Ke [2 ]
Zhao, Ying [3 ]
Fan, Jun [1 ]
Han, Tingting [1 ]
Si, Yu-an [2 ]
Zhou, Bin [1 ,5 ]
Zhang, Jue [1 ]
Hu, Zhigang [4 ]
Xie, Minhao [1 ,5 ]
机构
[1] Jiangsu Inst Nucl Med, NHC Key Lab Nucl Med, Jiangsu Key Lab Mol Nucl Med, 20 Qianrong Rd, Wuxi 214063, Jiangsu, Peoples R China
[2] Jiangyin Peoples Hosp, Dept Clin Lab, 163 Shoushan Rd, Jiangyin 214400, Jiangsu, Peoples R China
[3] Jiangsu Inst Nucl Med, Dept Gynecol, Jiangyuan Hosp, 18 Qianrong Rd, Wuxi 214063, Jiangsu, Peoples R China
[4] Nanjing Med Univ, Wuxi Peoples Hosp, Dept Clin Lab, Wuxi Childrens Hosp, 299 Qingyang Rd, Wuxi 214023, Jiangsu, Peoples R China
[5] Nanjing Med Univ, Sch Pharm, Dept Radiopharmaceut, 109 Longmian Ave, Nanjing 211166, Jiangsu, Peoples R China
关键词
Human epidermal growth factor receptor 2; Human epididymis protein 4; Time-resolved fluoroimmunoassay; Gynecological cancer; Simultaneous detection; BREAST-CANCER; OVARIAN; DIAGNOSIS; HE-4; STATISTICS; HER2;
D O I
10.1186/s40543-019-0201-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a novel dual-label time-resolved fluoroimmunoassay (TRFIA) is described for simultaneous quantification of human epidermal growth factor receptor 2 (HER-2) and human epididymis protein 4 (HE4) in serum to screen gynecologic cancers. A double-antibody sandwich TRFIA was introduced with europium and samarium chelates to simultaneously detect the concentrations of HER-2 and HE4. Under optimal conditions, the proposed method exhibited wide linear ranges for HER-2 of 0.07-500 ng ml(-1) and for HE4 of 0.32-1000 pmol l(-1) with the average coefficient of variation below 10%. The specificity was satisfied through determining the other common tumor markers. The recovery rates were 94.5% and 96.6% on average for HER-2 and HE4, respectively. Good correlations were observed in clinical samples between developed method and commercial chemiluminescence immunoassay kits. The results demonstrated that dual-label TRFIA for HER-2 and HE4 was rapid and precise, and therefore could have a promising use in large sample detection for gynecological cancer screening.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Dual-label time-resolved fluoroimmunoassay for simultaneous measurement of human epidermal growth factor receptor 2 and human epididymis protein 4 in serum
    Yi Zhang
    Ke Wang
    Ying Zhao
    Jun Fan
    Tingting Han
    Yu-an Si
    Bin Zhou
    Jue Zhang
    Zhigang Hu
    Minhao Xie
    Journal of Analytical Science and Technology, 11
  • [2] Dual-label time-resolved fluoroimmunoassay of psychopharmaceuticals and stimulants in serum
    Kimura, H
    Mukaida, M
    Wang, GL
    Yuan, JL
    Matsumoto, K
    FORENSIC SCIENCE INTERNATIONAL, 2000, 113 (1-3) : 345 - 351
  • [3] DUAL-LABEL TIME-RESOLVED FLUOROIMMUNOASSAY FOR THE SIMULTANEOUS DETECTION OF ADENOVIRUS AND ROTAVIRUS IN FECES
    SIITARI, H
    JOURNAL OF VIROLOGICAL METHODS, 1990, 28 (02) : 179 - 188
  • [4] DUAL-LABEL TIME-RESOLVED FLUOROIMMUNOASSAY FOR SIMULTANEOUS DETECTION OF MYOGLOBIN AND CARBONIC ANHYDRASE-III IN SERUM
    VUORI, J
    RASI, S
    TAKALA, T
    VAANANEN, K
    CLINICAL CHEMISTRY, 1991, 37 (12) : 2087 - 2092
  • [5] Simultaneous determination of the cytokeratin 19 fragment and carcinoembryonic antigen in human serum by magnetic nanoparticle-based dual-label time-resolved fluoroimmunoassay
    Lin, Guanfeng
    Zhao, Hui
    Liu, Tiancai
    Hou, Jingyuan
    Ren, Zhiqi
    Huang, Wenhua
    Dong, Wenqi
    Wu, Yingsong
    RSC ADVANCES, 2014, 4 (98): : 55229 - 55236
  • [6] Dual-label time-resolved fluoroimmunoassay for simultaneous detection of aflatoxin B1 and ochratoxin A
    Huang, Biao
    Xiao, Hualong
    Zhang, Jue
    Zhang, Lianfen
    Yang, Hailin
    Zhang, Yi
    Jin, Jian
    ARCHIVES OF TOXICOLOGY, 2009, 83 (06) : 619 - 624
  • [7] A competitive dual-label time-resolved fluoroimmunoassay for the simultaneous determination of chloramphenicol and ractopamine in swine tissue
    ZHANG Zhen LIU JingFu YAO Yan JIANG GuiBin State Key Laboratory of Environmental Chemistry and EcotoxicologyResearch Center for EcoEnvironmental SciencesChinese Academy of SciencesBeijing China Department of IsotopeChina Institute of Atomic EnergyBeijing China
    Chinese Science Bulletin, 2011, 56 (15) : 1543 - 1547
  • [8] A competitive dual-label time-resolved fluoroimmunoassay for the simultaneous determination of chloramphenicol and ractopamine in swine tissue
    Zhang Zhen
    Liu JingFu
    Yao Yan
    Jiang GuiBin
    CHINESE SCIENCE BULLETIN, 2011, 56 (15): : 1543 - 1547
  • [9] A competitive dual-label time-resolved fluoroimmunoassay for the simultaneous determination of chloramphenicol and ractopamine in swine tissue
    ZHANG Zhen 1
    2 Department of Isotope
    Science Bulletin, 2011, (15) : 1543 - 1547
  • [10] Dual-label time-resolved fluoroimmunoassay for simultaneous detection of aflatoxin B1 and ochratoxin A
    Biao Huang
    Hualong Xiao
    Jue Zhang
    Lianfen Zhang
    Hailin Yang
    Yi Zhang
    Jian Jin
    Archives of Toxicology, 2009, 83 : 619 - 624