Postoperative accuracy analysis of three-dimensional corrective osteotomy for cubitus varus deformity with a custom-made surgical guide based on computer simulation

被引:48
|
作者
Omori, Shinsuke [1 ]
Murase, Tsuyoshi [1 ]
Oka, Kunihiro [1 ]
Kawanishi, Yohei [1 ]
Oura, Keiichiro [1 ]
Tanaka, Hiroyuki [1 ]
Yoshikawa, Hideki [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Orthopaed Surg, Suita, Osaka 5650871, Japan
关键词
Accuracy analysis; three-dimensional; corrective osteotomy; cubitus varus; custom-made guide; computer simulation; POSTEROLATERAL ROTATORY INSTABILITY; DISPLACED SUPRACONDYLAR FRACTURES; TOTAL KNEE ARTHROPLASTY; ULNAR NERVE PALSY; DISTAL RADIUS; MALUNITED FRACTURES; UPPER EXTREMITY; HUMERUS; CHILDREN; ELBOW;
D O I
10.1016/j.jse.2014.08.020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: For correction of cubitus varus deformity resulting from supracondylar fracture of the humerus, we developed an operative method with use of a custom-made surgical guide, designed on the basis of 3-dimensional (3D) computer simulation with computed tomography data. The purpose of this study was to investigate the postoperative accuracy of this system in clinical cases. Methods: Subjects included 17 consecutive patients (13 males and 4 females) with cubitus varus deformity after supracondylar fracture. Patients underwent 3D corrective osteotomy with use of a custom-made surgical guide. Postoperative computed tomography scan was performed after bone union diagnosis on plain radiographs, and postoperative 3D bone models were compared with preoperative simulation by surface registration technique. In addition, we evaluated radiographic parameters (humerus-elbow-wrist angle and tilting angle) and range of elbow motion at the most recent follow-up. Results: Mean errors in 3D corrective osteotomy were 0.6 degrees +/- 0.7 degrees in varus-valgus rotation, 0.8 degrees +/- 1.3 degrees in flexion-extension rotation, 2.9 degrees +/- 2.8 degrees in internal-external rotation, 1.7 +/- 1.8 mm in anterior-posterior translation, 1.3 +/- 1.8 mm in lateral-medial translation, and 7.1 +/- 6.3 mm in proximal-distal translation. The mean humerus-elbow-wrist angle on plain radiographs of the affected side was 15 degrees in varus before surgery and improved to 6 degrees in valgus after surgery. The mean tilting angle of the affected side was 31 degrees before surgery and improved to 40 degrees after surgery. Conclusion: The 3D correction of cubitus varus deformity was performed accurately within the allowable error limits. (C) 2015 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:242 / 249
页数:8
相关论文
共 49 条
  • [1] Three-dimensional corrective osteotomy for cubitus varus in adults
    Chung, MS
    Baek, GH
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2003, 12 (05) : 472 - 475
  • [2] Corrective osteotomy for malunion of proximal humerus using a custom-made surgical guide based on three-dimensional computer planning: case report
    Ranalletta, Maximiliano
    Bertona, Agustin
    Rios, Juan M.
    Rossi, Luciano A.
    Tanoira, Ignacio
    Maignon, Gaston D.
    Sancineto, Carlos F.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (11) : E357 - E363
  • [3] Corrective osteotomy for malunited intra-articular fracture of the distal radius using a custom-made surgical guide based on three-dimensional computer simulation: Case report
    Oka, Kunihiro
    Moritomo, Hisao
    Goto, Akira
    Sugamoto, Kazuomi
    Yoshikawa, Hideki
    Murase, Tsuyoshi
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (06): : 835 - 840
  • [4] Computer-aided design and custom-made guide in corrective osteotomy for complex femoral deformity
    Chai, Wei
    Xu, Meng
    Zhang, Guo-qiang
    Zhang, Li-hai
    Gou, Wen-long
    Ni, Ming
    Chen, Ji-ying
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2013, 33 (03) : 398 - 405
  • [5] Computer-aided design and custom-made guide in corrective osteotomy for complex femoral deformity
    Wei Chai
    Meng Xu
    Guo-qiang Zhang
    Li-hai Zhang
    Wen-long Gou
    Ming Ni
    Ji-ying Chen
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2013, 33 : 398 - 405
  • [6] Efficacy evaluation of three-dimensional printing assisted osteotomy guide plate in accurate osteotomy of adolescent cubitus varus deformity
    Yuan-Wei Zhang
    Xin Xiao
    Wen-Cheng Gao
    Yan Xiao
    Su-Li Zhang
    Wen-Yan Ni
    Liang Deng
    Journal of Orthopaedic Surgery and Research, 14
  • [7] Efficacy evaluation of three-dimensional printing assisted osteotomy guide plate in accurate osteotomy of adolescent cubitus varus deformity
    Zhang, Yuan-Wei
    Xiao, Xin
    Gao, Wen-Cheng
    Xiao, Yan
    Zhang, Su-Li
    Ni, Wen-Yan
    Deng, Liang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (01)
  • [8] Cubitus Varus Corrective Osteotomy and Graft Fashioning Using Computer Simulated Bone Reconstruction and 3D Printed Custom-Made Cutting Guides
    Sedigh, Ashkan
    Zohoori, Mohammad
    Ebrahimzadeh, Mohammad
    Kachooei, Amir
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2021, 9 (04): : 467 - 471
  • [9] Single-plane rotational osteotomy for cubitus varus deformity based on preoperative computer simulation
    Oka, Kunihiro
    Murase, Tsuyoshi
    Okada, Kiyoshi
    Tanaka, Hiroyuki
    Yoshikawa, Hideki
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2019, 24 (05) : 945 - 951
  • [10] Three-dimensional corrective osteotomy using a patient-specific osteotomy guide and bone plate based on a computer simulation system: accuracy analysis in a cadaver study
    Omori, Shinsuke
    Murase, Tsuyoshi
    Kataoka, Toshiyuki
    Kawanishi, Yohei
    Oura, Keiichiro
    Miyake, Junichi
    Tanaka, Hiroyuki
    Yoshikawa, Hideki
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2014, 10 (02): : 196 - 202