Feedback control of sound transmission through a double glazed window

被引:51
|
作者
Kaiser, OE
Pietrzko, SJ
Morari, M
机构
[1] ETH, Swiss Fed Inst Technol, Automat Control Lab, CH-8092 Zurich, Switzerland
[2] EMPA, Swiss Fed Labs Mat Testing & Res, CH-8600 Dubendorf, Switzerland
关键词
D O I
10.1016/S0022-460X(02)01259-2
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
One way to tackle the control of stochastic noise in three dimensions is to reduce the sound transmission to the zone of interest. In buildings, windows are often the weak link in protecting the interior from outside noise. In particular, double glazed windows have a poor sound insulation at low frequency around the mass-air mass resonance (double wall resonance). Since passive means for windows are exhausted, an active controller that increases the transmission loss in the low-frequency range is an attractive approach to reduce the noise level in buildings. Previously suggested feedforward controllers need reference microphones to measure the disturbance outside and error microphones for the adaptation somewhere in the room. For a real window this is unpractical or even unfeasible. These limitations can be overcome with the feedback controller presented here, which only uses sensors and actuators in the cavity of the double glazed window. Four different controllers-two feedforward and two feedback strategies-are designed, implemented and compared. With feedback the noise transmission around the mass-air-mass resonance can be reduced by 13 dB, compared to 18 dB with a feedforward controller. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:775 / 795
页数:21
相关论文
共 50 条
  • [1] Experimental study for control of sound transmission through double glazed window using optimally tuned Helmholtz resonators
    Mao, Qibo
    Pietrzko, Stanislaw
    APPLIED ACOUSTICS, 2010, 71 (01) : 32 - 38
  • [2] Active control of the sound transmission through a double-glazing window
    DeFonseca, P
    Desmet, W
    Cops, A
    Cooper, J
    Sas, P
    INTER-NOISE 96 - THE 1996 INTERNATIONAL CONGRESS ON NOISE CONTROL ENGINEERING, 25TH ANNIVERSARY CONGRESS - LIVERPOOL, PROCEEDINGS, BOOKS 1-6: NOISE CONTROL - THE NEXT 25 YEARS, 1996, : 1811 - 1816
  • [3] Active Control of the Sound Transmission Through a Double-Glazing Window
    Proc Int Conf Noise Control Eng, 4 (1811):
  • [4] Analysis and experiments of sound transmission through double window panels
    Shimizu, Takafumi
    Hiraoka, Toshiki
    Toyoda, Masahiro
    Takahashi, Daiji
    Kawai, Yasuhito
    ACOUSTICAL SCIENCE AND TECHNOLOGY, 2008, 29 (06) : 397 - 398
  • [5] Development of Adaptive Methods for the Reduced Noise Transmission through a Symmetric Double-Glazed Window
    Klaus, Tim Bastian
    Herold, Sven
    Heuss, Oliver
    Melz, Tobias
    JOURNAL OF VIBRATION ENGINEERING & TECHNOLOGIES, 2016, 4 (03): : 201 - 212
  • [6] Optimisation of an active noise control system for reducing the sound transmission through a double-glazing window
    De Fonseca, P
    Sas, P
    Van Brussel, H
    MODERN PRACTICE IN STRESS AND VIBRATION ANALYSIS, 1997, : 207 - 214
  • [7] Sound transmission through an isolation window
    Langer, S
    Antes, H
    ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND MECHANIK, 2001, 81 : S589 - S590
  • [8] Active control of sound transmission through a honeycomb panel with feedforward and feedback control
    Sanada, Akira
    Tanaka, Nobuo
    MECHANICAL ENGINEERING JOURNAL, 2016, 3 (06):
  • [9] ACTIVE CONTROL OF SOUND-TRANSMISSION THROUGH A DOUBLE PANEL PARTITION
    SAS, P
    BAO, C
    AUGUSZTINOVICZ, F
    DESMET, W
    JOURNAL OF SOUND AND VIBRATION, 1995, 180 (04) : 609 - 625
  • [10] Active control of aircraft fly-over sound transmission through an open window
    Pamies, T.
    Romeu, J.
    Genesca, M.
    Arcos, Robert
    APPLIED ACOUSTICS, 2014, 84 : 116 - 121