Safety, efficacy, and maneuverability of a self-propelled capsule endoscope for observation of the human gastrointestinal tract

被引:3
|
作者
Ota, Kazuhiro [1 ]
Kojima, Yuichi [1 ]
Kakimoto, Kazuki [1 ]
Nouda, Sadaharu [1 ]
Takeuchi, Toshihisa [1 ]
Shindo, Yasunori [2 ]
Ohtsuka, Yoshitake [2 ]
Ohtsuka, Naotake [2 ]
Higuchi, Kazuhide [1 ]
机构
[1] Osaka Med Coll, Dept Internal Med 2, 2-7 Daigaku Machi, Takatsuki, Osaka 5698686, Japan
[2] Mu Ltd, Seta, Shiga, Japan
基金
日本学术振兴会;
关键词
TRIAL;
D O I
10.1055/a-1507-4540
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and study aims We developed a self-propelled capsule endoscope that can be controlled from outside the body with real-time observation. To improve the device, we conducted a clinical trial of total gastrointestinal capsule endoscopy in healthy subjects to ascertain whether our first-generation, self-propelled capsule endoscope was safe and effective for observing the entire human gastrointestinal tract. Patients and methods After adequate gastrointestinal pretreatment, five healthy subjects were instructed to swallow a self-propelling capsule endoscope and the safety of a complete gastrointestinal capsule endoscopy with this device was assessed. We also investigated basic problems associated with complete gastrointestinal capsule endoscopy. Results No adverse effects of the magnetic field were identified in any of the subjects. No mucosal damage was noted in any of the subjects with the use of our first-generation, self-propelling capsule endoscope. We found that it took longer than expected to observe the stomach; the view was compromised by the swallowed saliva. The pylorus was extremely difficult to navigate, and the endoscope's fin sometimes got caught in the folds of the small intestine and colon. Conclusions To resolve the problems associated with the existing self-propelling capsule endoscope, it may be necessary to not only improve the capsule endoscopes, but also to control the environment within the gastrointestinal tract with medications and other means. Our results could guide other researchers in developing capsule endoscopes controllable from outside the body, thus allowing real-time observation.
引用
收藏
页码:E1391 / E1396
页数:6
相关论文
共 50 条
  • [1] Design and Fabrication of a Magnetic Propulsion System for Self-Propelled Capsule Endoscope
    Gao, Mingyuan
    Hu, Chengzhi
    Chen, Zhenzhi
    Zhang, Honghai
    Liu, Sheng
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (12) : 2891 - 2902
  • [2] Nonlinear dynamic behavior of self-propelled capsule endoscope in small intestine environment
    Zhu J.
    Liao M.
    Zhu Z.
    Zeng Z.
    Li Z.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2022, 41 (21): : 86 - 96
  • [3] Evaluating the maneuverability of a new type of self-propelled barge
    LUO Wei1 and ZHANG Pan2 1. School of Transportation
    2. College of Electromechanical Engineering
    JournalofMarineScienceandApplication, 2007, (04) : 44 - 47
  • [4] Evaluating the maneuverability of a new type of self-propelled barge
    Luo Wei
    Zhang Pan
    JOURNAL OF MARINE SCIENCE AND APPLICATION, 2007, 6 (04) : 44 - 47
  • [5] Self-propelled turning motion and forecast analysis of the maneuverability of a trimaran
    Yu, Dong
    Zhou, Junwei
    Li, Jinhua
    Gui, Hongbin
    Wang, Wei
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2023, 44 (10): : 1645 - 1653
  • [6] On turning maneuverability in self-propelled burst-and-coast swimming
    Chao, Li-Ming
    Couzin, Iain D.
    Li, Liang
    PHYSICS OF FLUIDS, 2024, 36 (11)
  • [7] Observation of Whole Digestive Tract of a Human by a Single Passage of a Self-Propelling Capsule Endoscope
    Ohtsuka, Naotake
    Umegaki, Eiji
    Shindo, Yasunori
    Uesugi, Kenshiro
    Nishihara, Hironori
    Nouda, Sadaharu
    Kojima, Yuichi
    Tokioka, Satoshi
    Higuchi, Kazuhide
    GASTROINTESTINAL ENDOSCOPY, 2012, 75 (04) : 126 - 126
  • [8] Autonomous Locomotion of Capsule Endoscope in Gastrointestinal Tract
    Yang, Sungwook
    Park, Kitae
    Kim, Jinseok
    Kim, Tae Song
    Cho, Il-Joo
    Yoon, Eui-Sung
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 6659 - 6663
  • [9] The analysis of experiment of the submarine self-propelled model's astern maneuverability
    Liu Ruijie
    Xiao Changrun
    Chen Dongbin
    INFORMATION TECHNOLOGY APPLICATIONS IN INDUSTRY II, PTS 1-4, 2013, 411-414 : 3068 - +
  • [10] Development of a Self-Propelled Capsule Robot for Pipeline Inspection
    Yusupov, Azat
    Liu, Yang