A discrete polar Stockwell transform for enhanced characterization of tissue structure using MRI

被引:2
|
作者
Pridham, Glen [1 ,2 ,3 ]
Steenwijk, Martijn D. [4 ]
Geurts, Jeroen J. G. [4 ]
Zhang, Yunyan [1 ,2 ,3 ]
机构
[1] Univ Calgary, Dept Radiol, Calgary, AB, Canada
[2] Univ Calgary, Dept Clin Neurosci, Calgary, AB, Canada
[3] Univ Calgary, Hotchkiss Brain Inst, Calgary, AB, Canada
[4] Vrije Univ Amsterdam, Med Ctr, Dept Anat & Neurosci, Amsterdam, Netherlands
基金
加拿大自然科学与工程研究理事会;
关键词
image texture; multiresolution; multiple sclerosis; rotation-invariant; spectral density; Stockwell transform; S-TRANSFORM; SPECTRUM; LOCALIZATION; IMAGES;
D O I
10.1002/mrm.27219
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to present an effective algorithm for computing the discrete polar Stockwell transform (PST), investigate its unique multiscale and multi-orientation features, and explore potentially new applications including denoising and tissue segmentation. Theory and Methods: We investigated PST responses using both synthetic and MR images. Moreover, we compared the features of PST with both Gabor and Morlet wavelet transforms, and compared the PST with two wavelet approaches for denoising using MRI. Using a synthetic image, we also tested the edge effect of PST through signal-padding. Then, we constructed a partially supervised classifier using radial, marginal PST spectra of T2-weighted MRI, acquired from postmortem brains with multiple sclerosis. The classification involved three histology-verified tissue types: normal appearing white matter (NAWM), lesion, or other, along with 5-fold cross-validation. Results: The PST generated a series of images with varying orientations or rotation-invariant scales. Radial frequencies highlighted image structures of different size, and angular frequencies enhanced structures by orientation. Signal-padding helped suppress boundary artifacts but required attention to incidental artifacts. In comparison, the Gabor transform produced more redundant images and the wavelet spectra appeared less spatially smooth than the PST. In addition, the PST demonstrated lower root-mean-square errors than other transforms in denoising and achieved a 93% accuracy for NAWM pixels (296/317), and 88% accuracy for lesion pixels (165/188) in MRI segmentation. Conclusions: The PST is a unique local spectral density-assessing tool which is sensitive to both structure orientations and scales. This may facilitate multiple new applications including advanced characterization of tissue structure in standard MRI.
引用
收藏
页码:2731 / 2743
页数:13
相关论文
共 50 条
  • [1] Evaluation of discrete orthogonal versus polar Stockwell Transform for local multi-resolution texture analysis using brain MRI of multiple sclerosis patients
    Pridham, Glen
    Oladosu, Olayinka
    Zhang, Yunyan
    MAGNETIC RESONANCE IMAGING, 2020, 72 : 150 - 158
  • [2] Image encryption using discrete orthogonal Stockwell transform with fractional Fourier transform
    Ranjan, Rajeev
    Thakur, Abhishek
    MULTIMEDIA TOOLS AND APPLICATIONS, 2023, 82 (12) : 18517 - 18527
  • [3] Image encryption using discrete orthogonal Stockwell transform with fractional Fourier transform
    Rajeev Ranjan
    Abhishek Thakur
    Multimedia Tools and Applications, 2023, 82 : 18517 - 18527
  • [4] Enhanced phase extraction in optical coherence elastography using discrete cosine transform for localized tissue characterization
    Satpathy, Sweta
    Poddar, Raju
    LASER PHYSICS, 2025, 35 (03)
  • [5] Electrocardiogram data compression using DCT based discrete orthogonal Stockwell transform
    Jha, Chandan Kumar
    Kolekar, Maheshkumar H.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2018, 46 : 174 - 181
  • [6] Medical Image Compression with Thresholding Denoising Using Discrete Cosine- Based Discrete Orthogonal Stockwell Transform
    Yu, Qianlei
    Sun, Fengrong
    Babyn, Paul
    Zhang, Cuicui
    Liu, Fanglei
    Qin, Jiaojiao
    Yu, Haitao
    Yao, Guihua
    PROCEEDINGS OF 2017 3RD IEEE INTERNATIONAL CONFERENCE ON COMPUTER AND COMMUNICATIONS (ICCC), 2017, : 1857 - 1860
  • [7] Ocular Artifact Removal from EEG Signals Using Discrete Orthonormal Stockwell Transform
    Upadhyay, R.
    Padhy, P. K.
    Kankar, P. K.
    2015 ANNUAL IEEE INDIA CONFERENCE (INDICON), 2015,
  • [8] Colorectal polyp detection in colonoscopy videos using image enhancement and discrete orthonormal stockwell transform
    Nisha, J. S.
    Gopi, Varun Palakuzhiyil
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2022, 47 (04):
  • [9] Colorectal polyp detection in colonoscopy videos using image enhancement and discrete orthonormal stockwell transform
    J S Nisha
    VARUN PALAKUZHIYIL Gopi
    Sādhanā, 47
  • [10] Color image encryption using singular value decomposition in discrete cosine Stockwell transform domain
    Vaish, Ankita
    Kumar, Manoj
    OPTICA APPLICATA, 2018, 48 (01) : 25 - 38