Fluorescence ELISA for sensitive detection of ochratoxin A based on glucose oxidase-mediated fluorescence quenching of CdTe QDs

被引:53
|
作者
Liang, Yi [1 ,3 ]
Huang, Xiaolin [1 ]
Yu, Ruijin [2 ]
Zhou, Yaofeng [1 ]
Xiong, Yonghua [1 ,3 ]
机构
[1] Nanchang Univ, State Key Lab Food Sci & Technol, Nanchang 330047, Peoples R China
[2] Northwest A&F Univ, Coll Sci, Yangling 712100, Shaanxi, Peoples R China
[3] Nanchang Univ, Jiangxi OAI Joint Res Inst, Nanchang 330047, Peoples R China
关键词
Immunoassay; Ochratoxin A; Glucose oxidase; Fluorescence quenching; Quantum dots; LINKED-IMMUNOSORBENT-ASSAY; QUANTUM DOTS; SILICA NANOSPHERES; IMMUNOASSAY; NANOCRYSTALS; RESIDUES; AVIDIN; PROBES;
D O I
10.1016/j.aca.2016.06.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present study described a novel fluorescence enzyme-linked immunosorbent assay (ELISA) used to detect ochratoxin A (OTA) by using the glucose oxidase (GOx)-mediated fluorescence quenching of mercaptopropionic acid-capped CdTe quantum dots (MPA-QDs), in which GOx was used as an alternative to horseradish peroxidase (HRP) for the oxidization of glucose into hydrogen peroxide (H2O2) and gluconic acid. The MPA-QDs were used as a fluorescent signal output, whose fluorescence variation was extremely sensitive to the presence of H2O2 or hydrogen ions in the solution. Under the optimized conditions, the proposed fluorescence ELISA demonstrated a good linear detection of OTA in corn extract from 2.4 pg mL(-1) to 625 pg mL(-1) with a limit of detection of 2.2 pg mL(-1), which was approximately 15-fold lower than that of conventional HRP-based ELISA. Our developed fluorescence immunoassay was also similar to HRP-based ELISA in terms of selectivity, accuracy, and reproducibility. In summary, this study was the first to use the GOx-mediated fluorescence quenching of QDs in immunoassay to detect OTA, offering a new possibility for the analysis of other mycotoxins and biomolecules. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:195 / 201
页数:7
相关论文
共 50 条
  • [1] Fluorescence ELISA based on glucose oxidase-mediated fluorescence quenching of quantum dots for highly sensitive detection of Hepatitis B
    Wu, Yunqing
    Zeng, Lifeng
    Xiong, Ying
    Leng, Yuankui
    Wang, Hui
    Xiong, Yonghua
    TALANTA, 2018, 181 : 258 - 264
  • [2] Ultrasensitive fluorescence immunoassay for detection of ochratoxin A using catalase-mediated fluorescence quenching of CdTe QDs
    Huang, Xiaolin
    Zhan, Shengnan
    Xu, Hengyi
    Meng, Xianwei
    Xiong, Yonghua
    Chen, Xiaoyuan
    NANOSCALE, 2016, 8 (17) : 9390 - 9397
  • [3] Fluorescence ELISA based on CAT-regulated fluorescence quenching of CdTe QDs for sensitive detection of FB1
    Lu, Tianying
    Zhan, Shengnan
    Zhou, Yaofeng
    Chen, Xirui
    Huang, Xiaolin
    Leng, Yuankui
    Xiong, Yonghua
    Xu, Yang
    ANALYTICAL METHODS, 2018, 10 (48) : 5797 - 5802
  • [4] Glucose oxidase conjugated H2O2 sensitive CdTe QDs: an effective fluorescence tool for glucose sensing
    Singh, Pooja
    Prabhune, Asmita A.
    Ogale, Satishchandra B.
    Guin, Debanjan
    JOURNAL OF MATERIALS CHEMISTRY B, 2013, 1 (47) : 6538 - 6543
  • [5] Determination of rifampicin based on fluorescence quenching of GSH capped CdTe/ZnS QDs
    Liu, Zhengqing
    Yin, Pengfei
    Gong, Huiping
    Li, Pingping
    Wang, Xiaodan
    He, Youqiu
    JOURNAL OF LUMINESCENCE, 2012, 132 (09) : 2484 - 2488
  • [6] Efficient detection of aklomide/nitromide based on a sensor of MPA capped CdTe QDs using fluorescence quenching method
    Wang, Yuting
    Liu, Jia
    Yang, Bin
    Zhang, Fengming
    Liu, Xin
    Niu, Shiyue
    Bi, Shuyun
    FOOD CHEMISTRY, 2024, 441
  • [7] A practical aptaprobe for sulfadimethoxine residue detection in water and fish based on the fluorescence quenching of CdTe QDs by poly (diallyldimethylammonium chloride)
    Chen, Xiang-Xiu
    Lin, Zheng-Zhong
    Yao, Qiu-Hong
    Huang, Zhi-Yong
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2020, 91
  • [8] Gold nanoparticle-mediated fluorescence immunoassay for rapid and sensitive detection of Ochratoxin A
    Zhang, Junxiang
    Xu, Die
    Zhang, Yan
    Luo, Zhenzhen
    Zhao, Yanan
    Zheng, Xiaolong
    Yang, Hualin
    Zhou, Yu
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 304
  • [9] A simple fluorescence method detection levofloxacin in milk based on GSH-CdTe QDs
    Tan, Xuanping
    Li, Qin
    Yang, Jidong
    JOURNAL OF MOLECULAR STRUCTURE, 2020, 1201
  • [10] A fluorescence nanoprobe of N-Acetyl-L-Cysteine capped CdTe QDs for sensitive detection of nitrofurazone
    Wang, Yuting
    Zhang, Fengming
    Liu, Jia
    Yang, Bin
    Yuan, Yue
    Zhou, Yanyan
    Bi, Shuyun
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 297