Toward Personalized Dosimetry with 32P Microparticle Therapy for Advanced Pancreatic Cancer

被引:6
|
作者
Gholami, Yaser Hadi [1 ]
Wilson, Nicole [2 ]
James, David [2 ]
Kuncic, Zdenka [1 ]
机构
[1] Univ Sydney, Inst Med Phys, Sch Phys, Sydney, NSW, Australia
[2] OncoSil Med, Sydney, NSW, Australia
关键词
RADIONUCLIDE THERAPY; RADIATION; GEMCITABINE; TUMOR;
D O I
10.1016/j.ijrobp.2017.07.031
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To develop a Monte Carlo model for patient-specific dosimetry of P-32 microparticle localized internal radionuclide therapy for advanced pancreatic cancer. Methods and Materials: Spherical tumor geometries and a pancreatic phantom were modeled, as well as different 3-dimensional non-uniform clinical pancreatic geometries based on patient-specific ultrasound images. The dosimetry simulations modeled the dose distribution due to the energy spectrum of emitted beta particles. Results: The average dose for small (3-cm diameter) and large (6-cm diameter) spherical tumors was 111 Gy (for 7.6 MBq administered activity) and 128 Gy (for 58 MBq), respectively. For the clinical 3-dimensional geometries, on the basis of patient data, the mean doses delivered to the tumor were calculated to be in the range 102 to 113 Gy, with negligible dose to the pancreas for the smallest tumor volumes. The calculated dose distributions are highly non-uniform. For the largest tumor studied, the pancreas received approximately 6% of the tumor dose (5.7 Gy). Importantly, we found that because the smallest tumor studied exhibited the most dynamic changes in volume in response to the treatment, the dose to tumor and pancreas is significantly underestimated if a static tumor volume is assumed. Conclusions: These results demonstrate the dosimetry of P-32 microparticle localized internal radionuclide therapy for pancreatic cancer and the possibility of developing personalized treatment strategies. The results also highlight the importance of considering the effects of non-uniform dose distributions and dynamic change of tumor mass during treatment on the dosimetry of the tumor and critical organs. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:1029 / 1038
页数:10
相关论文
共 50 条
  • [1] Bioevaluation of a Novel [32P]-CP-PLLA Microparticle for Pancreatic Cancer Treatment
    Yang, Min
    Xu, Yuping
    Pan, Donghui
    Wang, Lizhen
    Luo, Shineng
    Shao, Guoqiang
    Liu, Lu
    Hunag, Peilin
    DRUG DEVELOPMENT RESEARCH, 2010, 71 (06) : 364 - 370
  • [2] 32P as an adjunct to standard therapy for locally advanced unresectable pancreatic cancer:: A randomized trial
    Rosemurgy, Alexander
    Luzardo, German
    Cooper, Jennifer
    Bowers, Carl
    Zervos, Emmanuel
    Bloomston, Mark
    Al-Saadi, Sam
    Carroll, Robert
    Chheda, Hemant
    Carey, Larry
    Goldin, Steven
    Grundy, Shane
    Kudryk, Bruce
    Zwiebel, Bruce
    Black, Thomas
    Briggs, John
    Chervenick, Paul
    JOURNAL OF GASTROINTESTINAL SURGERY, 2008, 12 (04) : 682 - 688
  • [3] 32P as an Adjunct to Standard Therapy for Locally Advanced Unresectable Pancreatic Cancer: A Randomized Trial
    Alexander Rosemurgy
    German Luzardo
    Jennifer Cooper
    Carl Bowers
    Emmanuel Zervos
    Mark Bloomston
    Sam Al-Saadi
    Robert Carroll
    Hemant Chheda
    Larry Carey
    Steven Goldin
    Shane Grundy
    Bruce Kudryk
    Bruce Zwiebel
    Thomas Black
    John Briggs
    Paul Chervenick
    Journal of Gastrointestinal Surgery, 2008, 12 : 682 - 688
  • [4] Intratumoural 32P therapy in irresectable pancreatic carcinoma
    McCready, VR
    Grundy, A
    Glees, JP
    Van Every, R
    Heriot, AG
    Knight, MJ
    Massoomi, MA
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (01): : S85 - S85
  • [5] Dosimetry of 32P radiocolloid for treatment of cystic craniopharyngioma
    Sadeghi, Mahdi
    Moradi, Somayeh
    Shahzadi, Sohrab
    Pourbeigi, Hossien
    APPLIED RADIATION AND ISOTOPES, 2007, 65 (05) : 519 - 523
  • [6] 32P endovascular brachytherapy source experimental dosimetry
    Fidanzio, A
    Perrone, F
    Azario, L
    Grimaldi, L
    Capote, R
    Piermattei, A
    RADIOTHERAPY AND ONCOLOGY, 2004, 71 : S87 - S87
  • [7] Dosimetry of 32P Radiocolloid for Radiotherapy of Brain Cyst
    Sadeghi, M.
    Karimi, E.
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 1220 - +
  • [9] EUS-Delivered therapy for pancreatic cancer:: Initial experience with targeted injection of 32P Biosilicon™
    Meenan, John
    Mesenas, Steven
    Douglas, Nivea
    Heatley, Sarah
    Doig, Laura
    Ross, Paul
    GASTROINTESTINAL ENDOSCOPY, 2007, 65 (05) : AB208 - AB208
  • [10] New personalized Therapy Options for advanced Pancreatic Cancer
    Franke, Katharina
    ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2025, 63 (03):