Extraction of Input Function from Rat [18F]FDG PET Images

被引:8
|
作者
Kudomi, Nobuyuki [1 ,2 ]
Bucci, Marco [1 ]
Oikonen, Vesa [1 ]
Silvennoinen, Mika [3 ]
Kainulainen, Heikki [3 ]
Nuutila, Pirjo [1 ,4 ]
Iozzo, Patricia [1 ,5 ]
Roivainen, Anne [1 ,6 ]
机构
[1] Univ Turku, Turku PET Ctr, Turku, Finland
[2] Kagawa Univ, Fac Med, Dept Med Phys, Kagawa, Japan
[3] Univ Jyvaskyla, Dept Biol Phys Activ, SF-40100 Jyvaskyla, Finland
[4] Univ Turku, Dept Med, Turku, Finland
[5] CNR, Inst Clin Physiol, Pisa, Italy
[6] Univ Turku, Turku Ctr Dis Modeling, Turku, Finland
基金
芬兰科学院;
关键词
Small animal; F-18]FDG; PET; Input function; BRAIN TRANSFER CONSTANTS; SMALL-ANIMAL PET; GRAPHICAL EVALUATION; METABOLIC-RATE; IN-VIVO; GLUCOSE; MODEL; FDG;
D O I
10.1007/s11307-010-0449-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Small animal positron emission tomography (PET) with 2-deoxy-2-[F-18]fluoro-d-glucose ([F-18]FDG) facilitates the visualization and quantification of glucose uptake in rats and mice. The quantification of glucose uptake requires an input function, which is generally obtained by measuring radioactivity in arterial plasma withdrawn during PET imaging; however, this approach is not always feasible because abundant blood sampling may affect the physiological process being measured. The purpose of the present study was to develop a new model-based technique (K-Model) and compare it to the previous F-Model. Materials and Methods: The study material consisted of two separate groups of rats having different physiological conditions. Each group was scanned by different PET cameras, i.e., HRRT and Inveon-PET/CT, and blood samples were drawn during imaging. Two kinds of model functions, i.e., F-Model and K-Model, were used for estimating input functions by an optimization procedure, applying restrictions on boundary conditions. To validate the method, glucose influx rate, K (i), was computed from the estimated and measured input functions for comparison. Results: The input functions were well reproduced when single-point blood count data were used for both models. The difference in K (i) values between the model-based and blood sampling methods was 1.1 +/- 15.1% by K-Model which showed the most feasible in the study. The regression analysis showed a tight correlation between the image-based and blood sampling methods, and the slope was close to unity and the intercept close to zero. Conclusion: It is possible to estimate the input function from rat [F-18]FDG PET images, thus facilitating the assessment of glucose metabolism without affecting the physiological conditions of the animal as a result of abundant blood sampling.
引用
收藏
页码:1241 / 1249
页数:9
相关论文
共 50 条
  • [1] Extraction of Input Function from Rat [18F]FDG PET Images
    Nobuyuki Kudomi
    Marco Bucci
    Vesa Oikonen
    Mika Silvennoinen
    Heikki Kainulainen
    Pirjo Nuutila
    Patricia Iozzo
    Anne Roivainen
    Molecular Imaging and Biology, 2011, 13 : 1241 - 1249
  • [2] Extraction of Input Function from 18FDG-PET Images
    Mabrouk, Rostom
    Croteau, Etienne
    Bentabet, Layachi
    Sarrhini, Otman
    Beaudoin, Jean-Francois
    Dubeau, Francois
    Bentourkia, M'hamed
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3571 - 3575
  • [3] Input Functions Extraction from Gated 18F-FDG PET Images
    Mabrouk, R.
    Bentabet, L.
    Dubeau, F.
    Bentourkia, M.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2982 - 2986
  • [4] A deep learning model for generating [18F]FDG PET Images from early-phase [18F]Florbetapir and [18F]Flutemetamol PET images
    Sanaat, Amirhossein
    Boccalini, Cecilia
    Mathoux, Gregory
    Perani, Daniela
    Frisoni, Giovanni B.
    Haller, Sven
    Montandon, Marie-Louise
    Rodriguez, Cristelle
    Giannakopoulos, Panteleimon
    Garibotto, Valentina
    Zaidi, Habib
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 (12) : 3518 - 3531
  • [5] Deep learning based generation of high-count preclinical [18F]-FDG PET images from low-count [18F]-FDG PET images
    Dutta, Kaushik
    Whitehead, Timothy
    Laforest, Richard
    Jha, Abhinav
    Shoghi, Kooresh
    JOURNAL OF NUCLEAR MEDICINE, 2022, 63
  • [6] Robustness of radiomic features in [18F]-FDG PET/CT and [18F]-FDG PET/MR
    Vuong, D.
    Bogowicz, M.
    Huellner, M.
    Veit-Haibach, P.
    Andratschke, N.
    Unkelbach, J.
    Guckenberger, M.
    Tanadini-Lang, S.
    JOURNAL OF THORACIC ONCOLOGY, 2018, 13 (04) : S41 - S41
  • [7] [18F]FDG PET/CT outperforms [18F]FDG PET/MRI in differentiated thyroid cancer
    Vrachimis, Alexis
    Burg, Matthias Christian
    Wenning, Christian
    Allkemper, Thomas
    Weckesser, Matthias
    Schaefers, Michael
    Stegger, Lars
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 (02) : 212 - 220
  • [8] [18F]FDG PET/CT outperforms [18F]FDG PET/MRI in differentiated thyroid cancer
    Alexis Vrachimis
    Matthias Christian Burg
    Christian Wenning
    Thomas Allkemper
    Matthias Weckesser
    Michael Schäfers
    Lars Stegger
    European Journal of Nuclear Medicine and Molecular Imaging, 2016, 43 : 212 - 220
  • [9] Robustness study on radiomic features in [18F]-FDG PET/CT and [18F]-FDG PET/MR
    Vuong, D.
    Bogowicz, M.
    Huellner, M.
    Veit-Haibach, P.
    Andratschke, N.
    Unkelbach, J.
    Guckenberger, M.
    Tanadini-Lang, S.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1159 - S1159
  • [10] Interchangeability of radiomic features between [18F]-FDG PET/CT and [18F]-FDG PET/MR
    Diem Vuong
    Tanadini-Lang, Stephanie
    Huellner, Martin W.
    Veit-Haibach, Patrick
    Unkelbach, Jan
    Andratschke, Nicolaus
    Kraft, Johannes
    Guckenberger, Matthias
    Bogowicz, Marta
    MEDICAL PHYSICS, 2019, 46 (04) : 1677 - 1685