Experimental investigation of dependence of power quality from the operation mode of the ultra high-power electric arc furnace

被引:0
|
作者
Kornilov, Gennady Petrovich [1 ]
Nikolaev, Alexander Arkadyevich [1 ]
Khramshin, Timur Rifhatovich [1 ]
Shemetov, Andrey Nikolayevich [1 ]
机构
[1] Nosov Magnitogorsk State Tech Univ, Dept Elect Engn & Electrotechnol Syst, Magnitogorsk, Russia
关键词
power quality problem; electric arc furnace; static Var compensator;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This study sets the problem of estimating the efficient operation of the ultra high-power EAF with static Var compensator in different operation modes from the point of view of power quality. The results of the experimental study of electric power quality at 35 kV primary side of the furnace transformer are presented in this article. It is, shown that the coefficients of fluctuation, asymmetrical and non-sinusoidal voltage exceed the limited rated parameters. One should pay attention to higher performance on the regulated component of SVC side, i.e. on the side of TCR directly.
引用
收藏
页码:40 / 43
页数:4
相关论文
共 50 条
  • [1] MODE OF OPERATION AND RESULTS OF A 45-TON HIGH-POWER ELECTRIC-ARC FURNACE
    LIESTMANN, WD
    WIEMER, HE
    STAHL UND EISEN, 1973, 93 (06): : 217 - 222
  • [2] ULTRA HIGH-POWER ARC FURNACE SYSTEMS
    HARRISON, WL
    ELECTRICAL REVIEW, 1973, 192 (17): : 605 - 606
  • [3] ULTRA-HIGH POWER ELECTRIC STEEL FURNACE OPERATION
    ROBINSON, CG
    SCHWABE, WE
    JOURNAL OF METALS, 1965, 17 (01): : 75 - &
  • [4] Selected parameters of electric power quality in the high voltage power network feeding the electric AC arc furnace
    Gala, Marek
    Jagiela, Kazimierz
    Garstka, Tomasz
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (08): : 99 - 103
  • [5] HEAT-TRANSFER FROM ELECTRIC-ARCS TO MOLTEN-METAL BATH IN ULTRA HIGH-POWER ARC STEELMAKING FURNACE
    LYAKISHEV, NP
    SNITKO, YP
    ORZHEKH, IM
    STEEL IN THE USSR, 1991, 21 (03): : 117 - 118
  • [6] ULTRA-HIGH-POWER ARC FURNACE INSTALLATIONS
    BECKERBARBROCK, U
    FELIX, W
    PAPACHRISTOS, G
    BROWN BOVERI REVIEW, 1978, 65 (02): : 103 - 113
  • [7] WEAR MECHANISM OF WALL LININGS OF A HIGH-POWER ELECTRIC-ARC STEEL FURNACE
    SAPIRO, VS
    TIMOSHENKO, SN
    CHERNYSHEV, AB
    LEGOSTAEV, GS
    BRAVERMAN, EM
    REFRACTORIES, 1981, 22 (5-6): : 280 - 282
  • [8] Ultra-high chemical power electric arc furnace for 320 t/h
    Gottardi, Riccardo
    Miani, Stefano
    Partyka, Adam
    Engin, Bulend
    STAHL UND EISEN, 2008, 128 (08): : 19 - +
  • [9] Ultra-high chemical power electric arc furnace for 320 t/h
    Gottardi, Riccardo
    Miani, Stefano
    Partyka, Adam
    Engin, Bulend
    2008, Verlag Stahleisen GmbH (128):
  • [10] Power Quality Analysis of AC Electric Arc Furnace Connected to Power Grids
    Chen, Tianxin
    Wang, Liang
    Yan, Wei
    Wang, Enrong
    Zhang, Hailong
    2017 3RD INTERNATIONAL CONFERENCE ON MECHATRONIC SYSTEMS AND MATERIALS APPLICATION (ICMSMA 2017), 2017, : 16 - 21