Quantitative Chemical Sensing Employing Bioluminescent Bacteria

被引:0
|
作者
Uziel, Y. [1 ,2 ]
Kabessa, Y. [1 ,2 ]
Shpigel, E. [3 ]
Shemer, B. [3 ]
Belkin, S. [3 ]
Agranat, A. J. [1 ,2 ]
机构
[1] Hebrew Univ Jerusalem, Dept Appl Phys, IL-9190401 Jerusalem, Israel
[2] Hebrew Univ Jerusalem, Brojde Ctr Innovat Engn & Comp Sci, IL-9190401 Jerusalem, Israel
[3] Hebrew Univ Jerusalem, Inst Life Sci, Dept Plant & Environm Sci, IL-9190401 Jerusalem, Israel
关键词
D O I
10.1117/12.2584792
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We present a methodology for quantitative sensing of the contents of a target material (TM) in a given sample which employs biosensing bioluminescent bacteria. These bacteria are genetically engineered to respond to the presence of a specific TM in their microenvironment by producing bioluminescence. Herein, we extend this methodology to include quantitative sensing of the TM content in the inspected sample by exploiting the dependence of the bioluminescence produced by the bacteria on the content of the TM in the inspected sample. However, employing bacteria as precise measurement devices is inherently problematic, as the signal they produce varies between different batches of bacteria, and changes as the batch ages. Moreover, As the methodology is designed for outdoor operation, the sensitivity of the bacteria response to changes in the environmental conditions needs to be taken into account. These hurdles are overcome in a special optoelectronic sensor which measures in parallel the responses produced by the inspected sample, and a standard sample containing a known quantity of the TM. Both measurements are conducted by identical sensing channels using bacteria from the same batch, and under the same environmental conditions. The "standard ratio" (SR) defined as the ratio between the maximum responses of the inspected sample and the standard sample was found to be independent of the batch and environmental conditions. A calibration curve of the SR vs. the TM concentration in a set of pre-prepared samples is used to gauge SR at the sensor output to the TM concentration in the inspected sample.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] QUANTITATIVE ANALYSIS OF PHOSPHOLIPIDS OF SOME MARINE BIOLUMINESCENT BACTERIA
    EBERHARD, A
    ROUSER, G
    LIPIDS, 1971, 6 (06) : 410 - &
  • [2] Bioluminescent bacteria as indicators of chemical contamination of coastal waters
    Frischer, ME
    Danforth, JM
    Foy, TF
    Juraske, R
    JOURNAL OF ENVIRONMENTAL QUALITY, 2005, 34 (04) : 1328 - 1336
  • [3] Sensing antimonite and arsenite at the subattomole level with genetically engineered bioluminescent bacteria
    Ramanathan, S
    Shi, WP
    Rosen, BP
    Daunert, S
    ANALYTICAL CHEMISTRY, 1997, 69 (16) : 3380 - 3384
  • [4] SENSING OF CHEMICAL GRADIENTS BY BACTERIA
    KOSHLAND, DE
    HOPPE-SEYLERS ZEITSCHRIFT FUR PHYSIOLOGISCHE CHEMIE, 1974, 355 (02): : 105 - 106
  • [5] Bioluminescent bioreporter integrated circuit sensing of the chemical and biological spacecraft environment
    Ripp, SA
    Garland, JL
    Blalock, BJ
    Islam, SK
    Sayler, GS
    BIOLUMINESCENCE & CHEMILUMINESCENCE: PROGRESS AND PERSPECTIVES, 2005, : 433 - 436
  • [6] Quorum sensing on a global scale: Massive numbers of bioluminescent bacteria make milky seas
    Nealson, KH
    Hastings, JW
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2006, 72 (04) : 2295 - 2297
  • [7] Bacteria immobilization for a bioluminescent biosensor
    Pernetti, M
    Annesini, MC
    Merli, C
    Thouand, G
    Poncelet, D
    MINERVA BIOTECNOLOGICA, 2006, 18 (01) : 51 - 56
  • [8] BIOLUMINESCENT BACTERIA FROM SQUID
    SIOPONGCO, MC
    RAYMUNDO, AK
    KALIKASAN-THE PHILIPPINE JOURNAL OF BIOLOGY, 1981, 10 (2-3): : 269 - 269
  • [9] THE EFFECT OF RADIATION ON BIOLUMINESCENT BACTERIA
    MANTEL, J
    FREIDIN, M
    PERRY, H
    BULICH, AA
    MEDICAL PHYSICS, 1982, 9 (05) : 806 - 806
  • [10] Bioluminescent bacteria ''on a chip'' developed
    Betts, KS