Functional topographic imaging of the human retina by confocal scanning laser angiography

被引:0
|
作者
Noack, J [1 ]
Schmidt-Erfurth, U [1 ]
Koop, N [1 ]
Birngruber, R [1 ]
机构
[1] Med Laser Ctr Luebeck GMBH, D-23562 Lubeck, Germany
来源
MEDICAL APPLICATIONS OF LASERS IN DERMATOLOGY, CARDIOLOGY, OPHTHALMOLOGY, AND DENTISTRY II, PROCEEDINGS OF | 1999年 / 3564卷
关键词
ophthalmology; confocal imaging; angiography; data processing; topography;
D O I
10.1117/12.339146
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We present a new method for processing confocal fluorescence angiographies in order to extract the topography of the perfused surface. The topographies extracted for various normal and pathologic conditions agree well with morphological and functional conditions. They allow, for example, the quantification of leakage and the verification of treatment sucess in photodynamic therapy and provide thus a new valuable tool for analysing the topography of functional pathologies.
引用
收藏
页码:132 / 137
页数:6
相关论文
共 50 条
  • [1] Contrast Enhancement for Topographic Imaging in Confocal Laser Scanning Microscopy
    Schnitzler, Lena
    Finkeldey, Markus
    Hofmann, Martin R.
    Gerhardt, Nils C.
    APPLIED SCIENCES-BASEL, 2019, 9 (15):
  • [2] Non-interferometric volumetric imaging in living human retina by confocal oblique scanning laser ophthalmoscopy
    Shao, Wenjun
    Yi, Ji
    BIOMEDICAL OPTICS EXPRESS, 2022, 13 (06) : 3576 - 3592
  • [3] Imaging of living mammalian retina ex vivo by confocal laser scanning microscopy
    Calzia, Daniela
    Bianchini, Paolo
    Ravera, Silvia
    Bachi, Angela
    Candiano, Giovanni
    Diaspro, Alberto
    Panfoli, Isabella
    ANALYTICAL METHODS, 2010, 2 (11) : 1816 - 1818
  • [4] In vivo confocal imaging of the retina in animal models using scanning laser ophthalmoscopy
    Seeliger, MW
    Beck, SC
    Pereyra-Muñoz, N
    Dangel, S
    Tsai, JY
    Luhmann, UFO
    van de Pavert, SA
    Wijnholds, J
    Samardzija, M
    Wenzel, A
    Zrenner, E
    Narfström, K
    Fahl, E
    Tanimoto, N
    Acar, N
    Tonagel, F
    VISION RESEARCH, 2005, 45 (28) : 3512 - 3519
  • [5] AXIAL INTENSITY DISTRIBUTION ANALYSIS OF THE HUMAN RETINA WITH A CONFOCAL SCANNING LASER TOMOGRAPH
    BARTSCH, DU
    FREEMAN, WR
    EXPERIMENTAL EYE RESEARCH, 1994, 58 (02) : 161 - 173
  • [6] CONFOCAL LASER SCANNING OPHTHALMOSCOPE - REPRODUCIBILITY OF OPTIC-NERVE HEAD TOPOGRAPHIC MEASUREMENTS WITH THE CONFOCAL LASER SCANNING OPHTHALMOSCOPE
    CIOFFI, GA
    ROBIN, AL
    EASTMAN, RD
    PERELL, HF
    SAFARAZI, FA
    KELMAN, SE
    OPHTHALMOLOGY, 1993, 100 (01) : 57 - 62
  • [7] Confocal scanning laser fluorescein angiography and simultaneous indocyanine green angiography
    Bellmann, C
    Holz, FG
    Rohrschneider, K
    Burk, ROW
    Volcker, HE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 2795 - 2795
  • [8] Oral fluorescein angiography with the confocal scanning laser ophthalmoscope
    Garcia, CR
    Rivero, ME
    Bartsch, DU
    Ishiko, S
    Takamiya, A
    Fukui, K
    Hirokawa, H
    Clark, T
    Yoshida, A
    Freeman, WR
    OPHTHALMOLOGY, 1999, 106 (06) : 1114 - 1118
  • [9] Confocal scanning laser fluorescein and indocyanine green angiography
    Holz, FG
    Bellmann, C
    Dithmar, S
    Rohrschneider, K
    Burk, ROW
    Volcker, HE
    OPHTHALMOLOGE, 1997, 94 (05): : 348 - 353
  • [10] IMAGING OF THE RETINA BY SCANNING LASER TOMOGRAPHY
    BILLE, JF
    GRIMM, B
    LIANG, J
    MUELLER, K
    NEW METHODS IN MICROSCOPY AND LOW LIGHT IMAGING, 1989, 1161 : 417 - 425