4-D X 3-D Ultrasound: Real-Time Scan Conversion, Filtering, and Display of Displacement Vectors with a Motorized Curvilinear Transducer

被引:10
|
作者
Pospisil, Eric R. [1 ]
Rohling, Robert [1 ]
Azar, Reza Zahiri [1 ]
Salcudean, Septimiu E. [1 ,2 ]
机构
[1] Univ British Columbia, Dept Mech Engn, Vancouver, BC V6T 1W5, Canada
[2] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC V6T 1W5, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
ELASTOGRAPHY; TISSUE;
D O I
10.1109/TUFFC.2010.1688
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Recent research in the field of elastography has sought to expand displacement tracking to three dimensions. Once the 3-D volumes of displacement data have been obtained, they must be scan converted so that further processing, such as inversion methods to obtain tissue elasticity, can take place in Cartesian coordinates. This paper details an efficient and geometrically accurate algorithm to scan convert 3-D volumes of displacement vectors obtained from a motorized sector transducer. The proposed algorithm utilizes the physical scan geometry to convert the 3-D volumes of displacement data to both Cartesian coordinates and Cartesian displacements. Spatially varying filters are also proposed to prevent aliasing while minimizing data loss. Validation of the system has shown the algorithm to be correct to floating point precision, and the 3-D scan conversion and filtering can be performed faster than the native rate of data acquisition for the motorized transducer.
引用
收藏
页码:2271 / 2283
页数:13
相关论文
共 50 条
  • [1] Real-Time 3-D Ultrasound Scan Conversion Using a Multicore Processor
    Zhuang, Bo
    Shamdasani, Vijay
    Sikdar, Siddhartha
    Managuli, Ravi
    Kim, Yongmin
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2009, 13 (04): : 571 - 574
  • [2] Real-time cylindrical curvilinear 3-D ultrasound imaging
    Pua, EC
    Yen, JT
    Smith, SW
    ULTRASONIC IMAGING, 2003, 25 (03) : 137 - 150
  • [3] Real-time cylindrical curvilinear 3-D ultrasound imaging
    Pua, EC
    Yen, JT
    Smith, SW
    2003 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2003, : 668 - 671
  • [4] Real-time, 3-D ultrasound with multiple transducer arrays
    Fronheiser, MP
    Light, ED
    Idriss, SF
    Wolf, PD
    Smith, SW
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (01) : 100 - 105
  • [5] Adaptive scan sequence for real-time ultrasound 3-D imaging
    Hashimoto, H
    Takeuchi, Y
    ULTRASONIC IMAGING, 2003, 25 (04) : 215 - 225
  • [6] Real-time 3-D intracranial ultrasound with an endoscopic matrix array transducer
    Light, Edward D.
    Mukundan, Srinivasan
    Wolf, Patrick D.
    Smith, Stephen W.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (08): : 1277 - 1284
  • [7] New 4-D imaging for real-time intraoperative MRI: Adaptive 4-D scan
    Tokuda, Junichi
    Morikawa, Shigehiro
    Haque, Hasnine A.
    Tsukamoto, Tetsuji
    Matsumiya, Kiyoshi
    Liao, Hongen
    Masamune, Ken
    Dohi, Takeyoshi
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2006, PT 1, 2006, 4190 : 454 - 461
  • [8] Adaptive 4-D scan for real-time intraoperative MRI
    Tokuda, J.
    Morikawa, S.
    Haque, H. A.
    Tsukamoto, T.
    Matsumiya, K.
    Liao, H.
    Masamune, K.
    Dohi, T.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2006, 1 : 290 - 292
  • [9] Dual lumen transducer probes for real-time 3-D interventional cardiac ultrasound
    Lee, W
    Idriss, SF
    Wolf, PD
    Smith, SW
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (09): : 1297 - 1304
  • [10] Real-time volume rendering of 4-D image using 3-D texture mapping
    Hwang, J
    Kim, JS
    Kim, JS
    Kim, IY
    Kim, SI
    MEDICAL IMAGING 2001: VISUALIZATION, DISPLAY, AND IMAGE-GUIDED PROCEDURES, 2001, 4319 : 557 - 563