The effects of time-variance on impedance measurements: examples of a corroding electrode and a battery cell

被引:9
|
作者
Murer, Nicolas [1 ]
Diard, Jean-Paul [1 ]
Petrescu, Bogdan [1 ]
机构
[1] Biologic SAS, 4 Rue Vaucanson, F-38170 Seyssinet Pariset, France
来源
关键词
EIS; non-stationarity; corrosion; in operando; battery cells; 4D impedance; NSD; ELECTROCHEMICAL IMPEDANCE; INSTANTANEOUS IMPEDANCE; SPECTRA; DISCHARGE; SYSTEMS; CHARGE; EIS;
D O I
10.5599/jese.725
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
When performing electrochemical impedance spectroscopy (EIS) measurements on a system, we must make sure it fulfills certain conditions. One of them is that it should be stationary that is to say, steady-state and time-invariant. Commonly studied systems are time-variant, for example a corroding electrode or a battery under operation. A corroding electrode sees its polarization resistance decrease with time. A passivating electrode sees its polarization resistance increase with time. These phenomena cause a deformation of the Nyquist impedance at low frequencies. This result was first simulated and validated by experimental measurements on a corroding steel sample undergoing uniform corrosion. The effect of performing impedance measurements on a discharging battery was also shown. Several methods are available to check and correct time-variance. The non-stationary distortion (NSD) indicator is used to separate valid and invalid data samples and the so called "4D impedance" method can easily produce instantaneous impedance data.
引用
收藏
页码:127 / 140
页数:14
相关论文
共 50 条
  • [2] EFFECTS OF OXIDIZING-AGENTS ON THE IMPEDANCE OF A CORRODING TITANIUM ELECTRODE
    KUCHUKBAEV, KG
    KICHIGIN, VI
    PROTECTION OF METALS, 1992, 28 (05): : 678 - 680
  • [3] IMPEDANCE MEASUREMENTS OF CORRODING MILD-STEEL IN AN AUTOMOTIVE FUEL ETHANOL WITH AND WITHOUT INHIBITOR IN A 2 AND 3 ELECTRODE CELL
    DESOUZA, JP
    MATTOS, OR
    SATHLER, L
    TAKENOUTI, H
    CORROSION SCIENCE, 1987, 27 (12) : 1351 - 1364
  • [4] ELECTRODE POLARIZATION EFFECTS IN BRAIN IMPEDANCE MEASUREMENTS
    SHALIT, M
    MAHLER, Y
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1967, 22 (06): : 591 - &
  • [5] Optimization of reference electrode position in a three-electrode cell for impedance measurements in lithium-ion rechargeable battery by finite element method
    Hoshi, Yoshinao
    Narita, Yuki
    Honda, Keiichiro
    Ohtaki, Tomomi
    Shitanda, Isao
    Itagaki, Masayuki
    JOURNAL OF POWER SOURCES, 2015, 288 : 168 - 175
  • [6] Influence of Electrode Connection Tracks on Biological Cell Measurements by Impedance Spectroscopy
    de Araujo, Arthur Luiz Alves
    Claudel, Julien
    Kourtiche, Djilali
    Nadi, Mustapha
    SENSORS, 2019, 19 (13):
  • [7] Effects of electrode geometry and cell location on single-cell impedance measurement
    Wang, Ji-Wei
    Wang, Min-Haw
    Jang, Ling-Sheng
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (06): : 1271 - 1276
  • [8] Simple Way of Making Free-Standing Battery Electrodes and their Use in Enabling Half-Cell Impedance Measurements via μ-Reference Electrode
    Morasch, Robert
    Suthar, Bharatkumar
    Gasteiger, Hubert A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (10)
  • [9] Development of a battery real-time state of health diagnosis based on fast impedance measurements
    Locorotondo, Edoardo
    Cultrera, Vincenzo
    Pugi, Luca
    Berzi, Lorenzo
    Pierini, Marco
    Lutzemberger, Giovanni
    JOURNAL OF ENERGY STORAGE, 2021, 38
  • [10] A Platinum Micro-Reference Electrode for Impedance Measurements in a PEM Water Electrolysis Cell
    Hartig-Weiss, Alexandra
    Bernt, Maximilian
    Siebel, Armin
    Gasteiger, Hubert A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (11)