Assessment of anal fistulas with high-resolution subtraction MR-fistulography: Comparison with surgical findings

被引:42
|
作者
Schaefer, O [1 ]
Lohrmann, C [1 ]
Langer, M [1 ]
机构
[1] Univ Freiburg Klinikum, Dept Radiol, Rontgendiagnost Abt, D-79106 Freiburg, Germany
关键词
anus; Crohn disease; fistula; magnetic resonance; contrast agent;
D O I
10.1002/jmri.10436
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate a new MR-imaging protocol defined as subtraction MR-fistulography for the detection of fistula-in-ano. Materials and Methods: A total of 36 patients (18 men, 18 women) with the clinical diagnosis of anal fistula or abscess who were scheduled for surgical exploration were preoperatively imaged at 1.5 T in the supine position; coronal STIR sequences and axial T1-weighted three-dimensional FLASH sequences before and after intravenous injection of gadobenate dimeglumine (Gd-BOPTA) were obtained. Image subtraction was routinely used. The image findings were compared with the findings at surgical exploration according to a uniform classification system. Results: A total of 46 fistulas were seen on subtraction MR-fistulography, whereas surgery described 41 fistulas. MRI and surgery concordantly depicted a total number of 40 fistulas, six fistulas were only described by MRI, and one fistula was only seen during surgery. A total of 27 abscesses were detected with MRI, compared to 22 during surgery. A total of 22 abscesses were concordantly diagnosed. Complete agreement between subtraction MR-fistulography and surgery occurred in 32 (89%) of the 36 patients. The four patients in whom both procedures disagreed had complex anal sepsis with multiple fistulas and/or abscesses due to Crohn disease. Conclusion: High-resolution subtraction MR-fistulography is an important complement to surgical exploration and especially suitable for investigating complex anal sepsis.
引用
收藏
页码:91 / 98
页数:8
相关论文
共 50 条
  • [1] The comparison of CT fistulography and MR imaging of perianal fistulae with surgical findings: a case–control study
    Gokhan Soker
    Bozkurt Gulek
    Cengiz Yilmaz
    Omer Kaya
    Muhammet Arslan
    Okan Dilek
    Mustafa Gorur
    Ferit Kuscu
    Oktay İrkorucu
    Abdominal Radiology, 2016, 41 : 1474 - 1483
  • [2] The comparison of CT fistulography and MR imaging of perianal fistulae with surgical findings: a case-control study
    Soker, Gokhan
    Gulek, Bozkurt
    Yilmaz, Cengiz
    Kaya, Omer
    Arslan, Muhammet
    Dilek, Okan
    Gorur, Mustafa
    Kuscu, Ferit
    Irkorucu, Oktay
    ABDOMINAL RADIOLOGY, 2016, 41 (08) : 1474 - 1483
  • [3] Comparison of High-Resolution MR Imaging and Digital Subtraction Angiography for the Characterization and Diagnosis of Intracranial Artery Disease
    Lee, N. J.
    Chung, M. S.
    Jung, S. C.
    Kim, H. S.
    Choi, C. -G.
    Kim, S. J.
    Lee, D. H.
    Suh, D. C.
    Kwon, S. U.
    Kang, D. -W.
    Kim, J. S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (12) : 2245 - 2250
  • [4] Neurolymphomatosis of the lumbar plexus: High-resolution MR neurography findings
    Moore, KR
    Blumenthal, DT
    Smith, AG
    Ward, JH
    NEUROLOGY, 2001, 57 (04) : 740 - 742
  • [5] Pulmonary alveolar microlithiasis: High-resolution CT and MR findings
    Hoshino, H
    Koba, H
    Inomata, SI
    Kurokawa, K
    Morita, Y
    Yoshida, K
    Akiba, H
    Abe, S
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (02) : 245 - 248
  • [6] High-Resolution MR Examination of the Scapholunate Ligament using a Microscopic Coil: Comparison with Direct MR Arthrography and Arthroscopy Findings
    Stouracova, A.
    Sprlakova-Pukova, A.
    Cizmar, I.
    Prochazkova, J.
    Janousova, E.
    Valis, P.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2016, 83 (05) : 327 - 331
  • [7] 3D high-resolution anorectal manometry in patients with perianal fistulas: comparison with 3D-anal ultrasound
    Felt-Bersma, Richelle J. F.
    Vlietstra, Maarten S.
    Vollebregt, Paul F.
    Han-Geurts, Ingrid J. M.
    Rempe-Sorm, Vera
    Mijnsbrugge, Grietje J. H. Vander
    Molenaar, Charlotte B. H.
    BMC GASTROENTEROLOGY, 2018, 18
  • [8] 3D high-resolution anorectal manometry in patients with perianal fistulas: comparison with 3D-anal ultrasound
    Richelle J. F. Felt-Bersma
    Maarten S. Vlietstra
    Paul F. Vollebregt
    Ingrid J. M. Han-Geurts
    Vera Rempe-Sorm
    Grietje J. H. Vander Mijnsbrugge
    Charlotte B. H. Molenaar
    BMC Gastroenterology, 18
  • [9] HIGH-RESOLUTION MRI OF JUXTA-SELLAR LESIONS - COMPARISON WITH CLINICAL, CT, AND SURGICAL FINDINGS
    DAVIS, PC
    HOFFMAN, JC
    BRAUN, IF
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1986, 7 (03) : 544 - 544
  • [10] Isolated Congenital Middle Ear Malformations: Comparison of Preoperative High-Resolution CT and Surgical Findings
    Zhang, Na
    Li, Yi
    Ma, Xiaobo
    Wang, Danni
    Li, Shuling
    Yan, Fei
    Zhao, Shouqin
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2020, 129 (03): : 216 - 223