Exact mass measurement on an electrospray ionization time-of-flight mass spectrometer: error distribution and selective averaging

被引:34
|
作者
Wu, JJ [1 ]
McAllister, H [1 ]
机构
[1] Johnson & Johnson Pharmaceut Res & Dev LLC, Drug Discovery, San Diego, CA 92121 USA
来源
JOURNAL OF MASS SPECTROMETRY | 2003年 / 38卷 / 10期
关键词
accurate mass; exact mass; time-of-flight; TOF data processing; flow-injection analysis;
D O I
10.1002/jms.516
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An automated, accurate and reliable way of acquiring and processing flow injection data for exact mass measurement using a bench-top electrospray ionization time-of-flight (ESI-TOF) mass spectrometer is described. Using Visual Basic programs, individual scans were selected objectively with restrictions on ion counts per second for both the compound of interest and the mass reference peaks. The selected 'good scans' were then subjected to two different data-processing schemes ('combine-then-center' and 'center-then-average'), and the results were compared at various ion count limit settings. It was found that, in general, the average of mass values from individual scans is more accurate than the centroid mass value of the combined (same) scans. In order to acquire a large number of good scans in one injection (to increase the sampling size for statistically valid averaging), an on-line dilution chamber was added to slow down the typically rapid mass chromatographic peak decay in flow-injection analysis. This simple addition worked well in automation without the need for manual sample dilution. In addition, by dissolving the reference compound directly into the mobile phase, manual syringe filling can be eliminated. Twenty-seven samples were analyzed with the new acquisition and process routines in positive electrospray ionization mode. For the best method found, the percentage of samples with RMS error less than 5 ppm was 100% with repetitive injection data (6 injections per sample), and 95% with single injection data. Afterwards, 31 other test samples were run (with MW ranging from 310 to 3493 Da, 21 samples in ESI+ and 10 in ESI- mode) and processed with similar parameters and 100% of them were mass-calculated to RMS error less than 5 ppm also. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:1043 / 1053
页数:11
相关论文
共 50 条
  • [1] Electrospray ionization time-of-flight mass spectrometer for elemental analysis
    Mahoney, PP
    Guzowski, JP
    Ray, SJ
    Hieftje, GM
    APPLIED SPECTROSCOPY, 1997, 51 (10) : 1464 - 1470
  • [2] Design and performance of an electrospray ionization time-of-flight mass spectrometer
    Håkansson, K
    Zubarev, RA
    Håkansson, P
    Laiko, V
    Dodonov, AF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (01): : 36 - 41
  • [4] ELECTROSPRAY-IONIZATION ON A REFLECTING TIME-OF-FLIGHT MASS-SPECTROMETER
    DODONOV, AF
    CHERNUSHEVICH, IV
    LAIKO, VV
    TIME-OF-FLIGHT MASS SPECTROMETRY, 1994, 549 : 108 - 123
  • [5] Collisional damping interface for an electrospray ionization time-of-flight mass spectrometer
    Krutchinsky, AN
    Chernushevich, IV
    Spicer, VL
    Ens, W
    Standing, KG
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (06) : 569 - 579
  • [6] Development of a tandem time-of-flight mass spectrometer with an electrospray ionization ion source
    Nagao, Hirofumi
    Shimma, Shuichi
    Hayakawa, Shigeo
    Awazu, Kunio
    Toyoda, Michisato
    JOURNAL OF MASS SPECTROMETRY, 2010, 45 (08): : 937 - 943
  • [7] Measurement of hydrophobicity of peptides in electrospray ionization time-of-flight mass spectrometry
    Zhou Yue-Ming
    Wang Wei-Ping
    Liang Hua-Zheng
    Zhang Xie
    Chen Huan-Wen
    Chen Lan-Hui
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2006, 33 (10) : 942 - 947
  • [8] Development and characterization of an electrospray ionization ion trap linear time-of-flight mass spectrometer
    Purves, RW
    Li, L
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (10) : 1085 - 1093
  • [9] Hyperthermal surface ionization in a time-of-flight mass spectrometer
    Weickhardt, C
    Draack, L
    Grotemeyer, J
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2000, 6 (04) : 319 - 323
  • [10] A new electrospray-ionization time-of-flight mass spectrometer with electrostatic wire ion guide
    Bondarenko, PV
    Macfarlane, RD
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1997, 160 (1-3): : 241 - 258