Containment versus impingement: finding a compromise for cup placement in total hip arthroplasty

被引:67
|
作者
Widmer, K.-H. [1 ]
机构
[1] Kantonsspital Schaffhausen, Dept Orthoped Surg & Traumatol, CH-8208 Schaffhausen, Switzerland
关键词
D O I
10.1007/s00264-007-0429-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Recommendations for cup containment and impingement may provide conflicting directions for component orientation in total hip arthroplasty. For optimal containment, the cup is positioned with respect to the acetabular bone, resulting in coincidence of the rim of the cup and the acetabulum. This results in good coverage and symmetric load transfer, leading to good long-term stability, but occasionally necessitates more abduction of the cup than that recommended by the safe zone. On the other hand, placement of the cup for an optimal range of motion would lead to only partial containment, with a higher risk of component loosening and revision. The most effective compromise is to use a prosthesis that has a large safe zone, realised by a high head-to-neck ratio, and orienting the cup such that a good containment is achieved and the safe zone is respected. Computer navigation or smart aiming devices may help to find the best relative orientation.
引用
收藏
页码:S29 / S33
页数:5
相关论文
共 50 条
  • [1] Containment versus impingement: finding a compromise for cup placement in total hip arthroplasty
    K.-H. Widmer
    International Orthopaedics, 2007, 31 : 29 - 33
  • [2] Accuracy considerations in navigated cup placement for total hip arthroplasty
    mNemoscience, Übach-Palenberg, Germany
    不详
    不详
    不详
    不详
    不详
    Proc. Inst. Mech. Eng. Part H J. Eng. Med., 2007, 7 (739-753):
  • [3] Validation of navigation assisted cup placement in total hip arthroplasty
    M. Ajith Kumar
    M. Shantharam Shetty
    Kanthi G. Kiran
    Abhishek R. Kini
    International Orthopaedics, 2012, 36 : 17 - 22
  • [4] Accuracy considerations in navigated cup placement for total hip arthroplasty
    Langlotz, U.
    Gr tzner, P. A.
    Bernsmann, K.
    Kowal, J. H.
    Tannast, M.
    Caversaccio, M.
    Nolte, L-P
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2007, 221 (H7) : 739 - 753
  • [5] Validation of navigation assisted cup placement in total hip arthroplasty
    Kumar, M. Ajith
    Shetty, M. Shantharam
    Kiran, Kanthi G.
    Kini, Abhishek R.
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (01) : 17 - 22
  • [6] Precision of acetabular cup placement in robotic integrated total hip arthroplasty
    Elson, Leah
    Dounchis, Jon
    Illgen, Richard
    Marchand, Robert C.
    Padgett, Douglas E.
    Bragdon, Charles R.
    Malchau, Henrik
    HIP INTERNATIONAL, 2015, 25 (06) : 531 - 536
  • [7] Radiologic evaluation of cup placement variation in conventional total hip arthroplasty
    Leichtle, U.
    Gosselke, N.
    Wirth, C. J.
    Rudert, M.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2007, 179 (01): : 44 - 52
  • [8] Evaluation of cup placement accuracy in computer assisted total hip arthroplasty
    Kaneta, Hiroki
    Shoji, Takeshi
    Ueki, Shinichi
    Morita, Hiroyuki
    Kozuma, Yosuke
    Adachi, Nobuo
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2025, 145 (01)
  • [9] Accuracy of computer-assisted cup placement in total hip arthroplasty
    Jolles, BM
    Genoud, P
    Hoffmeyer, P
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 301 - 305
  • [10] Association between cup fixation screw and iliopsoas impingement after total hip arthroplasty
    Ueki, Shinichi
    Shoji, Takeshi
    Kaneta, Hiroki
    Shozen, Hideki
    Adachi, Nobuo
    CLINICAL BIOMECHANICS, 2024, 118