Fast X-Ray Fluorescence Microtomography of Hydrated Biological Samples

被引:81
|
作者
Lombi, Enzo [1 ,2 ]
de Jonge, Martin D. [3 ]
Donner, Erica [1 ,2 ]
Kopittke, Peter M. [2 ,4 ]
Howard, Daryl L. [3 ]
Kirkham, Robin [5 ]
Ryan, Chris G. [5 ]
Paterson, David [3 ]
机构
[1] Univ S Australia, Ctr Environm Risk Assessment & Remediat, Mawson Lakes, SA, Australia
[2] CRC CARE, Salisbury, SA, Australia
[3] Australian Synchrotron, Xray Fluorescence Microscopy, Clayton, Vic, Australia
[4] Univ Queensland, Sch Agr & Food Sci, St Lucia, Qld, Australia
[5] CSIRO, Clayton, Vic 3168, Australia
来源
PLOS ONE | 2011年 / 6卷 / 06期
关键词
TOXICITY; NICKEL; ZINC; ELEMENTS; GROWTH; PLANTS; RICE; IRON; PIXE;
D O I
10.1371/journal.pone.0020626
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Metals and metalloids play a key role in plant and other biological systems as some of them are essential to living organisms and all can be toxic at high concentrations. It is therefore important to understand how they are accumulated, complexed and transported within plants. In situ imaging of metal distribution at physiological relevant concentrations in highly hydrated biological systems is technically challenging. In the case of roots, this is mainly due to the possibility of artifacts arising during sample preparation such as cross sectioning. Synchrotron x-ray fluorescence microtomography has been used to obtain virtual cross sections of elemental distributions. However, traditionally this technique requires long data acquisition times. This has prohibited its application to highly hydrated biological samples which suffer both radiation damage and dehydration during extended analysis. However, recent advances in fast detectors coupled with powerful data acquisition approaches and suitable sample preparation methods can circumvent this problem. We demonstrate the heightened potential of this technique by imaging the distribution of nickel and zinc in hydrated plant roots. Although 3D tomography was still impeded by radiation damage, we successfully collected 2D tomograms of hydrated plant roots exposed to environmentally relevant metal concentrations for short periods of time. To our knowledge, this is the first published example of the possibilities offered by a new generation of fast fluorescence detectors to investigate metal and metalloid distribution in radiation-sensitive, biological samples.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Diffraction enhanced imaging and x-ray fluorescence microtomography for analyzing biological samples
    Rocha, H. S.
    Pereira, G. R.
    Anjos, M. J.
    Faria, P.
    Kellermann, G.
    Perez, C. A.
    Tirao, G.
    Mazzaro, I.
    Giles, C.
    Lopes, R. T.
    X-RAY SPECTROMETRY, 2007, 36 (04) : 247 - 253
  • [2] X-ray fluorescence microtomography analyzing reference samples
    Pereira, G. R.
    Lopes, R. T.
    Anjos, M. J.
    Rocha, H. S.
    Perez, C. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (01): : 322 - 325
  • [3] Contrasting of Biological Samples for X-Ray Synchrotron Microtomography
    Efimova, O. I.
    Khlebnikov, A. S.
    Senin, R. A.
    Voronin, P. A.
    Anokhin, K. V.
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2013, 155 (04) : 413 - 416
  • [4] Contrasting of Biological Samples for X-Ray Synchrotron Microtomography
    O. I. Efimova
    A. S. Khlebnikov
    R. A. Senin
    P. A. Voronin
    K. V. Anokhin
    Bulletin of Experimental Biology and Medicine, 2013, 155 : 413 - 416
  • [5] High-resolution X-ray fluorescence microtomography of homogeneous samples
    Simionovici, A
    Chukalina, M
    Schroer, C
    Drakopoulos, M
    Snigirev, A
    Snigireva, I
    Lengeler, B
    Janssens, K
    Adams, F
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (06) : 2736 - 2740
  • [6] Elemental distribution images in prostate samples by X-ray fluorescence microtomography
    Pereira, G. R.
    Rocha, H. S.
    Anjos, M. J.
    Lima, I.
    Lopes, R. T.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (07) : 1379 - 1383
  • [7] DETERMINATION OF CALCIUM IN BIOLOGICAL SAMPLES BY X-RAY FLUORESCENCE
    CHAMPION, KP
    WHITTEM, RN
    ANALYST, 1967, 92 (1091) : 112 - &
  • [8] X-Ray Fluorescence Microtomography Investigates the Elemental Distribution in Breast Tissue Samples
    Pereira, Gabriela R.
    Rocha, Henrique S.
    Anjos, Marcelino J.
    Faria, Paulo
    Perez, Carlos A.
    Lopes, Ricardo T.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3932 - 3935
  • [9] Elemental distribution in breast tissue samples using X-ray fluorescence microtomography
    Pereira, G. R.
    Conceicao, S. C.
    Lopes, R. T.
    Anjos, M. J.
    Oliveira, L. F.
    Rocha, H. S.
    Perez, C. A.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2006, 269 (02) : 469 - 473
  • [10] Elemental distribution in breast tissue samples using X-ray fluorescence microtomography
    G. R. Pereira
    S. C. Conceiç?o
    R. T. Lopes
    M. J. Anjos
    L. F. Oliveira
    H. S. Rocha
    C. A. Perez
    Journal of Radioanalytical and Nuclear Chemistry, 2006, 269 : 469 - 473