Simultaneous assessment of endogenous thiol compounds by LC-MS/MS

被引:29
|
作者
Sun, Yao [1 ]
Yao, Tong [1 ]
Guo, Xiucai [1 ]
Peng, Ying [1 ]
Zheng, Jiang [2 ,3 ]
机构
[1] Shenyang Pharmaceut Univ, Sch Pharm, POB 50,103 Wenhua Rd, Shenyang 110016, Liaoning, Peoples R China
[2] Shenyang Pharmaceut Univ, Minist Educ, Key Lab Struct Based Drug Design & Discovery, Shenyang 110016, Liaoning, Peoples R China
[3] Univ Washington, Seattle Childrens Res Inst, Div Gastroenterol & Hepatol, Ctr Dev Therapeut,Dept Pediat,Sch Med, Seattle, WA 98101 USA
基金
中国国家自然科学基金;
关键词
LC-MS/MS; Simultaneous assessment; Thiol compounds; LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; HUMAN-PLASMA; BIOLOGICAL SAMPLES; CAPILLARY-ELECTROPHORESIS; FLUORESCENCE DETECTION; PARKINSONS-DISEASE; GLUTATHIONE; CYSTEINE; HOMOCYSTEINE;
D O I
10.1016/j.jchromb.2016.06.024
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Biological thiol compounds are very important molecules that participate in various physiological events. Alteration in levels of endogenous thiols has been suggested as a biomarker of early stage of pathological changes. We reported a chemical derivatization- and LC-MS/MS-based approach to simultaneously determine thiol compounds including glutathione (GSH), cysteine (Cys), N-acetyl cysteine (NAC), homocysteine (Hcy), and cysteinylglycine (CysGly) in biological samples. Thiol-containing samples were derivatized with monobromobimane (mBrB) at room temperature, followed by LC-MS/MS analysis. Assessment of the analytes with baseline separation was completed within 10 min, using a gradient elution on a C-18 reversed-phase column. Excellent linearity was observed for all analytes over their concentration ranges of 1-400 mu M. The lowest limits of detection (S/N = 3) in a range from 0.31 fmol (for NAC) to 4.98 fmol (for CysGly) were achieved. The results indicate that this approach was sensitive, selective, and well suited for high-throughput quantitative determination of the biological thiols. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:213 / 221
页数:9
相关论文
共 50 条
  • [1] Simultaneous determination of four endogenous steroids in bio matrices by LC-MS/MS
    Ranganathan, Premanand
    Gunasekaran, V.
    Singhvi, Indrajeet
    Alfarraj, Saleh
    Usmani, Salma
    Ansari, Mohammad Javed
    JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2021, 33 (01)
  • [2] Derivatization methods for LC-MS analysis of endogenous compounds
    Zhu, Yunting
    Deng, Pan
    Zhong, Dafang
    BIOANALYSIS, 2015, 7 (19) : 2557 - 2581
  • [3] Criteria of slope and endogenous level for selection of matrix in the quantitation of endogenous compounds by LC-MS/MS
    Ji, Allena Ji
    Xu, Guangxin
    Tao, Lin
    Jiao, Hongqin Jenny
    Palmer, Rachel Elisabeth
    BIOANALYSIS, 2022, 14 (11) : 807 - 816
  • [4] Simultaneous determination of six kinds of amadori compounds in tobaccos by LC-MS/MS
    Jia, Chun-Xiao
    Xiu, Long-Fei
    Mou, Ding-Rong
    Mao, Duo-Bin
    Journal of Chinese Mass Spectrometry Society, 2015, 36 (01) : 45 - 51
  • [5] Simultaneous determination of sweeteners in beverages by LC-MS/MS
    Sakai, Hiroaki
    Yamashita, Azusa
    Tamura, Masayoshi
    Uyama, Atsuo
    Mochizuki, Naoki
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2015, 32 (06): : 808 - 816
  • [6] Challenges and benefits of endogenous steroid analysis by LC-MS/MS
    Couchman, Lewis
    Vincent, Royce P.
    Ghataore, Lea
    Moniz, Caje F.
    Taylor, Norman F.
    BIOANALYSIS, 2011, 3 (22) : 2549 - 2572
  • [7] Quantitative analysis of thiol electrophile and redox modifications by LC-MS/MS
    Liebler, Daniel C.
    Yang, Jing
    Tallman, Keri A.
    Gupta, Vinayak
    Carroll, Kate S.
    Porter, Ned A.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248
  • [8] Simultaneous analysis of angiotensin peptides by LC-MS and LC-MS/MS: Metabolism by bovine adrenal endothelial cells
    Cui, Lijie
    Nithipatikom, Kasem
    Campbell, William B.
    ANALYTICAL BIOCHEMISTRY, 2007, 369 (01) : 27 - 33
  • [9] Quantitative electrospray LC-MS and LC-MS/MS in biomedicine
    Carrascal, M
    Schneider, K
    Calaf, RE
    van Leeuwen, S
    Canosa, D
    Gelpí, E
    Abian, J
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (6-7) : 1129 - 1138
  • [10] LC-MS/MS for the simultaneous determination of polar endogenous ADMA and CML in plasma and urine from diabetics
    Jing, Zhiqiang
    Kuang, Liqing
    Liu, Naifeng
    Yang, Jin
    BIOANALYSIS, 2015, 7 (10) : 1261 - 1271