Concept and performance testing of a high-capacity oil damper comprising multiple damper units

被引:11
|
作者
Yamamoto, Masashi [1 ]
Minewaki, Shigeo [1 ]
Nakahara, Manabu [2 ]
Tsuyuki, Yasuo [2 ]
机构
[1] Takenaka Corp, Inst Res & Dev, Chiba 2701395, Japan
[2] Kayaba Syst Machinery Co Ltd, Tokyo, Japan
来源
关键词
oil damper; high capacity; full-scale test; test method; supplemental damper;
D O I
10.1002/eqe.2728
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
There has been a significant increase in the size of building structures in recent years. Huge structures such as high-rise buildings and large-domed stadiums require high-performance structural control, including the use of high-capacity dampers, especially in an earthquake-prone country like Japan. The objective of the present study was the enhancement of both human and structural safety in such structures through the development of a rate-dependent type of damper with a high damping capacity. Among the various available types of rate-dependent dampers, the authors focused on the oil damper owing to its stable performance against long-duration vibrations. The target maximum damping force was 6000kN, which is higher than that of any existing oil damper utilized in building structures. The authors developed a novel concept for achieving this high capacity while maintaining the size of the damper within acceptable dimensions from an architectural point of view. The concept involves the use of multiple damper units that produce mechanically parallel damping forces spatially arranged in series. As a prototype, a 1500-kN oil damper was fabricated by combining three 500-kN dampers. The 1500-kN prototype damper was conceived as a full-scale prototype of a damper that is more slender than comparable commercially available dampers in Japan, and as a scaled model of the proposed 6000-kN damper. Sinusoidal loading tests were conducted on the prototype damper using a frequency range of 0.1-1.5Hz and a velocity range of 0.4-300mm/s. The results confirmed that the damper produced the design damping forces. The results of earthquake loading tests also revealed that the damper exerted a stable damping force against a large earthquake and maintained its performance after the earthquake. The damper is particularly effective against earthquakes with long-period components that could increase the temperature of a damper. This is afforded by its high heat capacity compared to conventional dampers. Considering that the proposed 6000-kN damper will generate a damping force that is about 2-3 times that of the strongest conventional oil damper, existing manufacturer test machines would be inadequate for evaluating its full performance characteristics. To address this issue, the authors also propose a test method for evaluating the overall damping force. The method is premised on the fact that the characteristic feature of the proposed damper is its combination of multiple damper units. The overall performance is thus evaluated using the test results for the individual damper units while the other dampers are bypassed. This method was verified by the results of the abovementioned sinusoidal loading tests, with the error for the 1500-kN prototype damper found to be less than 5%. Copyright (c) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:1919 / 1933
页数:15
相关论文
共 50 条
  • [1] Concept and performance testing of a high-capacity oil damper comprising multiple damper units
    Yamamoto, Masashi
    Minewaki, Shigeo
    Nakahara, Manabu
    Tsuyuki, Yasuo
    Earthquake Engineering and Structural Dynamics, 2016, 45 (12): : 1919 - 1933
  • [2] Prevention of low-frequency vibration of high-capacity steam turbine units by squeeze-film damper
    Kanki, H
    Kaneko, Y
    Kurosawa, M
    Yamamoto, T
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1998, 120 (02): : 391 - 396
  • [3] TESTING THE FUNCTIONALITY AND PERFORMANCE OF A RAIL DAMPER
    Mazilu, Traian
    Racanel, Ionut Radu
    Stoicescu, George
    ROMANIAN JOURNAL OF TRANSPORT INFRASTRUCTURE, 2018, 7 (02): : 31 - 39
  • [4] Concept and performance testing of an all-steel miniature dual stiffness damper
    Wang, Weiyang
    Liu, Ye
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 183
  • [5] A study on the performance of nonlinear viscous damper testing
    Su H.
    Pan W.
    Lan X.
    Yang X.
    Bai Y.
    Zhang X.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2019, 38 (20): : 61 - 69and76
  • [6] Assessment of seismic performance of an isolated structure equipped with a friction damper with coupling mechanism and an oil damper
    Zou, Shuang
    Wenliuhan, Heisha
    Inoue, Norio
    ADVANCES IN STRUCTURAL ENGINEERING, 2021, 24 (08) : 1599 - 1613
  • [7] DYNAMICS OF GAS AND OIL FIRED BOILERS OF HIGH-CAPACITY GENERATING UNITS
    PERELMAN, AS
    KHORKOV, NS
    THERMAL ENGINEERING, 1973, 20 (04) : 11 - 16
  • [8] Stochastic process testing for dynamic performance of damper member
    Lu, Fei
    Cheng, Wenrang
    Chen, Zhongfan
    Li, Aiqun
    Huang, Zhen
    ISISS 2005: Innovation & Sustainability of Structures, Vol 1-3, 2005, : 1324 - 1331
  • [9] TECHNOECONOMIC INDEXES OF HIGH-CAPACITY UNITS FOR PRIMARY CRUDE-OIL PROCESSING
    KALININ, AA
    FEIGIN, SA
    PROKHOROVA, AA
    CHEMISTRY AND TECHNOLOGY OF FUELS AND OILS, 1979, 15 (9-10) : 666 - 668
  • [10] Testing and performance of a new friction damper for seismic vibration control
    Martinez, Carlos A.
    Curadelli, Oscar
    JOURNAL OF SOUND AND VIBRATION, 2017, 399 : 60 - 74