Mid-infrared electric field characterization using a visible charge-coupled-device-based spectrometer

被引:64
|
作者
Kubarych, KJ [1 ]
Joffre, M
Moore, A
Belabas, N
Jonas, DM
机构
[1] Ecole Natl Super Tech Avancees, Ecole Polytech, INSERM, U51,UMR 7645,CNRS,Lab Opt & Biosci, F-91128 Palaiseau, France
[2] Univ Colorado, Dept Chem & Biochem, Boulder, CO 80309 USA
关键词
D O I
10.1364/OL.30.001228
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We characterize ultrashort mid-infrared pulses through upconversion by using the stretched pulses obtained from the uncompressed output of a chirped-pulse amplifier. The power spectrum thus translated into the visible region can be readily measured with a standard silicon CCD camera-based spectrometer. The spectral phase is also characterized by a variant of zero-added-phase spectral phase interferometry for direct electric field reconstruction. This is a general method that provides a multiplex advantage over conventional infrared detector array-based methods. (c) 2005 Optical Society of America.
引用
收藏
页码:1228 / 1230
页数:3
相关论文
共 50 条
  • [1] Noise characterization and compensation for a charge-coupled-device-based pyrometer
    Zhang, Yuzhong
    Lu, Fucheng
    Wang, Wenjing
    Shu, Shuangbao
    Dong, Jingtao
    Tao, Xiaojie
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (05):
  • [2] CHARGE-COUPLED-DEVICE-BASED IMAGING POLARIMETER FOR ASTRONOMY
    CLEMENS, DP
    LEACH, RW
    OPTICAL ENGINEERING, 1987, 26 (09) : 923 - 929
  • [3] INTENSIFIED CHARGE-COUPLED-DEVICE-BASED EYETRACKER AND IMAGE STABILIZER
    MILBOCKER, MT
    FEKE, GT
    APPLIED OPTICS, 1992, 31 (19): : 3719 - 3729
  • [4] A charge-coupled-device-based heterodyne technique for parallel photodisplacement imaging
    Nakata, T
    Ninomiya, T
    JOURNAL OF APPLIED PHYSICS, 2004, 96 (12) : 6970 - 6980
  • [5] A new infrared spectrometer with charge coupled device detector
    Yuan, HF
    Long, YC
    Xu, GT
    Lu, WZ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 27 (05) : 608 - 613
  • [6] A mid-infrared spectrometer based on difference frequency generation
    Deng, Lunhua
    Han, Ling
    Liang, Wanguo
    Cao, Zhensong
    Xu, Changqing
    Zhang, Weijun
    Gong, Zhiben
    Gao, Xiaoming
    OPTICS AND LASERS IN ENGINEERING, 2007, 45 (11) : 1055 - 1058
  • [7] Measurement performance analysis for a charge-coupled-device-based near-infrared multi-spectral pyrometer
    Zhang, Yuzhong
    Zhang, Wuqiong
    Dong, Zhe
    Shu, Shuangbao
    Lang, Xianli
    Yang, Lei
    INFRARED PHYSICS & TECHNOLOGY, 2020, 106
  • [8] Evaluation of a charge-coupled-device-based video sensor for aircraft cargo surveillance
    Sentenac, T
    Le Maoult, Y
    Orteu, JJ
    Boucourt, G
    OPTICAL ENGINEERING, 2002, 41 (04) : 796 - 810
  • [9] Simple interferometric fringe stabilization by charge-coupled-device-based feedback control
    Young, Preston P.
    Priambodo, Purnomo S.
    Maldonado, Theresa A.
    Magnusson, Robert
    APPLIED OPTICS, 2006, 45 (19) : 4563 - 4566
  • [10] Evaluation and improvement in the accuracy of a charge-coupled-device-based pyrometer for temperature field measurements of continuous casting billets
    Bai, Haicheng
    Xie, Zhi
    Zhang, Yuzhong
    Hu, Zhenwei
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (06):