Reliablity analysis of bridge beams retrofitted with fibre reinforced polymers

被引:31
|
作者
Pham, Huy Binh
Al-Mahaidi, Riadh [1 ]
机构
[1] Monash Univ, Dept Civil Engn, Head Struct Grp, Clayton, Vic 3800, Australia
[2] Maunsell Australia Pty Ltd, Melbourne, Vic 3000, Australia
关键词
FRP; retrofitting; debond; prediction model; reliability;
D O I
10.1016/j.compstruct.2006.12.010
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
This paper presents a study of reliability of RC beams retrofitted with FRP. The beams' variables and their variability are assessed. Three common failure modes are considered, i.e. flexural failure, intermediate span debond and end debond. The prediction models used in this study were developed previously by the authors. Monto Carlos simulation is carried out to study the variability of the capacity of CFRP-strengthened beams for each failure modes. A reliability analysis is carried out based on the guidance provided by Eurocode 2. The analysis provides the bases for recommendation of capacity reduction factors for different failure modes. It is found that a factor of 0.6 is needed for flexural failure and intermediate span debond; whereas a factor of 0.5 can be applied for end debond. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:177 / 184
页数:8
相关论文
共 50 条
  • [1] Efficient finite element modelling of reinforced concrete beams retrofitted with fibre reinforced polymers
    Barbato, M.
    COMPUTERS & STRUCTURES, 2009, 87 (3-4) : 167 - 176
  • [2] Performance of concrete structures retrofitted with fibre reinforced polymers
    Sheikh, SA
    ENGINEERING STRUCTURES, 2002, 24 (07) : 869 - 879
  • [3] Analysis of Fibre Reinforced Beams
    Mehrotra, Vivek
    JOURNAL OF POLYMER & COMPOSITES, 2023, 11 : S53 - S59
  • [4] The Behavior of RC Beams Retrofitted with Carbon Fiber Reinforced Polymers (CFRP)
    Fahim, Muhammad
    Alam, Fakhere
    Khan, Hazrat
    ul Haq, Inzimam
    Ullah, Shahid
    Zaman, Saeed
    ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2022, 12 (03) : 8701 - 8706
  • [5] Flexure Behavior of Carbon Fiber Reinforced Polymers Retrofitted RC Beams
    Fahim, Muhammad
    Saeed, Muhammad
    Khan, Haris
    Gir, Alam
    Ullah, Shahid
    ADVANCES IN SCIENCE AND TECHNOLOGY-RESEARCH JOURNAL, 2022, 16 (02) : 188 - 195
  • [6] Behaviour of RC columns retrofitted by fibre reinforced polymers under cyclic loads
    Shaheen, H
    Rakib, T
    Hashem, Y
    Shaaban, I
    Abdelrahman, A
    FIBRE-REINFORCEMENT POLYMER: REINFORCEMENT FOR CONCRETE STRUCTURES, VOLS 1 AND 2, PROCEEDINGS, 2003, : 663 - 672
  • [7] Effectiveness of anchorage in concrete beams retrofitted with sprayed fiber-reinforced polymers
    Lee, HK
    JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2004, 23 (12) : 1285 - 1300
  • [8] Numerical analysis of fibre reinforced polymer retrofitted masonry panels
    Luccioni, Bibiana
    Rougier, Viviana C.
    ENGINEERING STRUCTURES, 2013, 49 : 360 - 372
  • [9] Behaviour of steel beams retrofitted with anchored carbon-fibre-reinforced polymer strips
    Mercimek, Omer
    Ghoroubi, Rahim
    Baran, Mehmet
    Anil, Ozgur
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2022, 175 (07) : 561 - 576
  • [10] Shear strengthening of reinforced concrete beams using fibre reinforced polymers (FRP)
    Alzate, Albert
    Arteaga, Angel
    de Diego, Ana
    Perera, Ricardo
    EUROPEAN JOURNAL OF ENVIRONMENTAL AND CIVIL ENGINEERING, 2009, 13 (09) : 1051 - 1060