DNA biosensor-based on fluorescence detection of E-coli O157:H7 by Au@Ag nanorods

被引:36
|
作者
Sun, Jiadi [1 ]
Ji, Jian [1 ]
Sun, Yanqing [2 ]
Abdalhai, Mandour H. [1 ]
Zhang, Yinzhi [1 ]
Sun, Xiulan [1 ]
机构
[1] Jiangnan Univ, Synerget Innovat Ctr Food Safety & Nutr, Sch Food Sci & Technol, State Key Lab Food Sci & Technol, Wuxi 7214122, Jiangsu, Peoples R China
[2] Shaanxi Univ Technol, Sch Phys & Telecommun Engn, Hanzhong 723000, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Escherichia coli O157:H7; Au@Ag nanorods; Surface enhanced fluorescence DNAsensor; METAL-ENHANCED FLUORESCENCE; REAL-TIME PCR; SHIGA-TOXIN; ASSAY; EMISSION; O157/H7; O157-H7; SENSOR; O145; SERS;
D O I
10.1016/j.bios.2015.03.009
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel DNA sensor for the detection of the Escherichia coli O157:H7 (E. coli O157:H7) eaeA gene was constructed using surface enhanced fluorescence (SEF). The spacing distance dependence nature of Au@Ag nanorods surface enhanced fluorescence was investigated when the cy3-labled single strand DNA (ssDNA) and the stem-loop DNA probe modified on the nanorods was co-hybridized. The result revealed that the fluorescence intensity reached the maximum value with the spacing distance of about 10 nm between cy3 and the Au@Ag nanorods surface. Based on this result, a fluorescence "ON/OFF" switch for detecting the eaeA gene of E. coli O157:H7 was constructed. Under optimal conditions, the DNA sensor produced a linear range from 10(-17) to 10(-11) M with a correlation coefficient of 0.9947 and a detection limit of 3.33 x 10(-18) M, and was also found to be specific in targeting eaeA. The DNA sensor demonstrated a new strategy of combining eaeA recognition and Au@Ag nanorods for fluorescence signal enhancement, and increased sensitivity in the detection of bacterial specific genes. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:239 / 245
页数:7
相关论文
共 50 条
  • [1] Validation of a Modified ANSR® for E-coli O157:H7 Method for Detection of E-coli O157:H7 in Select Foods
    Alles, Susan
    Roman, Brooke
    Quynh-Nhi Le
    Hosking, Edan
    Colangelo, Wesley
    Tovar, Eric
    Biswas, Preetha
    Mozola, Mark
    Donofrio, Robert
    JOURNAL OF AOAC INTERNATIONAL, 2019, 102 (01) : 96 - 107
  • [2] A high density microelectrode array biosensor for detection of E-coli O157:H7
    Radke, SA
    Alocilja, EC
    BIOSENSORS & BIOELECTRONICS, 2005, 20 (08): : 1662 - 1667
  • [3] On the trial of E-coli O157:H7
    Lewis, R
    SCIENTIST, 1999, 13 (21): : 10 - 10
  • [4] Detection of E-coli O157:H7 DNA by a Novel QCM Biosensor coupled with Gold Nanoparticles Amplification
    Wang, Lijiang
    Wei, Qingshan
    Wu, Chunsheng
    Ji, Jian
    Liu, Qingjun
    Yang, Mo
    Wang, Ping
    2007 7TH IEEE CONFERENCE ON NANOTECHNOLOGY, VOL 1-3, 2007, : 330 - +
  • [5] Detection of E-coli O157:H7 using a miniaturized surface plasmon resonance biosensor
    Meeusen, CA
    Alocilja, EC
    Osburn, WN
    TRANSACTIONS OF THE ASAE, 2005, 48 (06): : 2409 - 2416
  • [6] The Wishaw E-coli O157:H7 outbreak
    Kohli, HS
    NATIONAL MEDICAL JOURNAL OF INDIA, 1997, 10 (03): : 145 - 146
  • [7] Immunohistochemical detection of E-coli O157:H7 in colonic tissue
    Alt, E
    Sigal, S
    Su, C
    Steinberg, JJ
    Kress, Y
    Brandt, L
    LABORATORY INVESTIGATION, 1996, 74 (01) : 299 - 299
  • [8] Validation of a method for the detection of E-coli O157:H7 in foods
    Scotter, S
    Aldridge, M
    Capps, K
    FOOD CONTROL, 2000, 11 (02) : 85 - 95
  • [9] A microsystem for extraction, capture and detection of E-Coli O157:H7
    Ashis Sen
    Tom Harvey
    Jan Clausen
    Biomedical Microdevices, 2011, 13 : 705 - 715
  • [10] Recognizing E-coli O157:H7 infection
    Greenwald, DA
    Brandt, LJ
    HOSPITAL PRACTICE, 1997, 32 (04): : 123 - &