High-throughput solid-phase extraction for the determination of cimetidine in human plasma

被引:35
|
作者
Hempenius, J
Wieling, J
Brakenhoff, JPG
Maris, FA
Jonkman, JHG
机构
[1] Pharma Bio Res Int BV, NL-9470 AE Zuidlaren, Netherlands
[2] Thiemann Arzneimittel GMBH, Dept Pharmacokinet, D-45731 Waltrop, Germany
来源
JOURNAL OF CHROMATOGRAPHY B | 1998年 / 714卷 / 02期
关键词
robotics; cimetidine; microtitre; solid-phase extraction; high-throughput sample preparation;
D O I
10.1016/S0378-4347(98)00232-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
For the implementation and validation of an automated 'high-throughput' solid-phase extraction (SPE) system, using microtiter solid-phase technology and a pipetting robot, a SPE method previously validated manually for cimetidine in human plasma was adapted. Sample cleanup was performed by means of SPE using Microlute extraction plates in the 96-well format, each well filled with 50 mg of Varian C-18 sorbent. Separation was performed by reversed-phase high-performance liquid chromatography (HPLC) with UV detection at 234 nm. The validated calibration range was from 0.100 to 5.00 mg/l, with an inaccuracy and imprecision below 20% at all concentration levels. Validation results on linearity, specificity, precision, accuracy and stability are shown and are found to be adequate. Cross-check analysis of samples from a clinical trial showed that there is a good correlation between results obtained by the automated method and results obtained by the manual method. The average sample preparation time for a technician decreased from approximately 4 min per sample to 0.6 min. A sample throughput of at least 160 samples per day can be achieved, the HPLC analysis time being the rate-limiting step. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:361 / 368
页数:8
相关论文
共 50 条
  • [1] High-throughput liquid chromatographic determination of rofecoxib in human plasma using a fully automated on-line solid-phase extraction system
    Hsieh, JYK
    Lin, L
    Matuszewski, BK
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2001, 24 (06) : 799 - 812
  • [2] Automation and miniaturization of solid-phase extraction for high-throughput analysis of cyanotoxins
    Melzer, Tommy
    Wichard, Thomas
    Moeller, Robert
    Ueberschaar, Nico
    Pohnert, Georg
    JOURNAL OF CHROMATOGRAPHY A, 2025, 1748
  • [3] Rapid, solid phase extraction technique for the high-throughput assay of darifenacin in human plasma
    Kaye, B
    Herron, WJ
    Macrae, PV
    Robinson, S
    Stopher, DA
    Venn, RF
    Wild, W
    ANALYTICAL CHEMISTRY, 1996, 68 (09) : 1658 - 1660
  • [4] Optimizing a High-Throughput Solid-Phase Microextraction System to Determine the Plasma Protein Binding of Drugs in Human Plasma
    Roy, Kanchan Sinha
    Nazdrajic, Emir
    Shimelis, Olga, I
    Ross, M. James
    Chen, Yong
    Cramer, Hugh
    Pawliszyn, Janusz
    ANALYTICAL CHEMISTRY, 2021, 93 (32) : 11061 - 11065
  • [5] Determination of Ligustrazine in Human Plasma by High Performance Liquid Chromatography with Solid-Phase Extraction
    Weng Weiyu
    Shen Teng
    Xu Huinan
    Zhang Jianfang
    Huang Jianming
    Huang Zhaochang
    Cai Jia
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2005, 23 (03) : 276 - 278
  • [6] Determination of cimetidine in human plasma by use of coupled-flow injection, solid-phase extraction, and capillary zone electrophoresis
    J. -W. Luo
    H. -W. Chen
    Q. -H. He
    Chromatographia, 2001, 53 : 295 - 300
  • [7] Determination of cimetidine in human plasma by use of coupled-flow injection, solid-phase extraction, and capillary zone electrophoresis
    Luo, JW
    Chen, HW
    He, QH
    CHROMATOGRAPHIA, 2001, 53 (5-6) : 295 - 300
  • [8] High-throughput, solid-phase assays on microwell platforms
    不详
    FASEB JOURNAL, 1998, 12 (05): : A1119 - A1119
  • [9] On-line solid-phase extraction and determination of paclitaxel in human plasma
    Mader, RM
    Rizovski, B
    Steger, GG
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 769 (02): : 357 - 361
  • [10] High-throughput biopolymer desalting by solid-phase extraction prior to mass spectrometric analysis
    Gilar, M
    Belenky, A
    Wang, BH
    JOURNAL OF CHROMATOGRAPHY A, 2001, 921 (01) : 3 - 13