Calibration and performance of the E706 lead and liquid-argon electromagnetic calorimeter

被引:11
|
作者
Apanasevich, L
Bacigalupi, J
Baker, W
Ballocchi, G
Begel, M
Benson, R
Blusk, S
Bromberg, C
Brown, D
Chang, P
Choudhary, B
Chung, WH
de Barbaro, L
DeSoi, W
Dlugosz, W
Dunlea, J
Engels, E
Fanourakis, G
Ferbel, T
Ftacnik, J
Garelick, D
Ginther, G
Glaubman, M
Gutierrez, P
Hartman, K
Huston, J
Johnstone, C
Kapoor, V
Kuehler, J
Lanaro, A
Lirakis, C
Lobkowicz, F
Lukens, P
Mani, S
Mansour, J
Maul, A
Miller, R
Oh, BY
Osborne, G
Pellett, D
Prebys, E
Roser, R
Sinanidis, A
Shepard, P
Shivpuri, R
Skow, D
Slattery, P
Sorrell, L
Striley, D
Toothacker, W
机构
[1] Fermi Natl Accelerator Lab, Batavia, IL 60510 USA
[2] Univ Calif Davis, Davis, CA 95616 USA
[3] Univ Delhi, Delhi 110007, India
[4] Michigan State Univ, E Lansing, MI 48824 USA
[5] Univ Minnesota, Minneapolis, MN 55455 USA
[6] Northeastern Univ, Boston, MA 02115 USA
[7] Univ Oklahoma, Norman, OK 73019 USA
[8] Penn State Univ, University Pk, PA 16802 USA
[9] Univ Pittsburgh, Pittsburgh, PA 15260 USA
[10] Univ Rochester, Rochester, NY 14627 USA
基金
美国国家科学基金会;
关键词
sampling electromagnetic calorimeter; calibration; direct photons;
D O I
10.1016/S0168-9002(98)00567-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report on the calibration and performance of a large lead liquid-argon electromagnetic calorimeter used by experiment E706 at Fermilab. The reconstructed pi(0) mass was used to calibrate the energy response of the calorimeter. The systematic uncertainty in the linearity and uniformity of the mean-energy response of the calorimeter after calibration was found to be less than +/- 0.5% for the sample of data analyzed. Detector characteristics, including sampling fluctuations and position resolution, are discussed. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:50 / 68
页数:19
相关论文
共 50 条
  • [1] Calibration and performance of the E706 lead and liquid-argon electromagnetic calorimeter
    Apanasevich, L.
    Bacigalupi, J.
    Baker, W.
    Ballocchi, G.
    Begel, M.
    Benson, R.
    Blusk, S.
    Bromberg, C.
    Brown, D.
    Chang, P.
    Choudhary, B.
    Chung, W.H.
    de Barbaro, L.
    DeSoi, W.
    Dlugosz, W.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 417 (01): : 50 - 68
  • [2] Calibration of the Fermilab E706 liquid argon electromagnetic calorimeter
    Varelas, N
    NUCLEAR PHYSICS B, 1995, : 153 - 157
  • [3] Performance and calibration of the DO uranium liquid-argon calorimeter
    Guida, J
    NUCLEAR PHYSICS B, 1995, : 158 - 162
  • [4] The ATLAS liquid-argon electromagnetic calorimeter
    Zolnierowski, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 384 (01): : 230 - 236
  • [5] LIQUID-ARGON IONIZATION CALORIMETER FOR DETECTION OF ELECTROMAGNETIC AND HADRONIC SHOWERS
    ENGLER, J
    FRIEND, B
    HOFMANN, W
    KEIM, H
    NICKSON, R
    SCHMIDTP.W
    SEGAR, A
    TYRRELL, M
    WEGENER, D
    WILLARD, T
    WINTER, K
    NUCLEAR INSTRUMENTS & METHODS, 1974, 120 (01): : 157 - 162
  • [6] Calibration of the ATLAS liquid argon electromagnetic calorimeter
    Serin, L
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 2000, : 447 - 452
  • [7] Energy-calibration of the ATLAS hadronic and electromagnetic liquid-argon endcap calorimeters
    Menke, S
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS , DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2004, 2 : 213 - 217
  • [8] PI/E DISCRIMINATION WITH A LEAD LIQUID ARGON CALORIMETER
    MICKE, U
    TRINES, D
    WALLRAFF, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 221 (03): : 495 - 502
  • [9] PERFORMANCE OF AN ACCORDION ELECTROMAGNETIC CALORIMETER WITH LIQUID KRYPTON AND ARGON
    BENARY, O
    CLELAND, W
    FERGUSON, I
    GORDEEV, A
    GORDON, H
    KISTENEV, E
    KROON, P
    LELTCHOUK, M
    LISSAUER, D
    MA, H
    MAKOWIECKI, D
    MASLENNIKOV, A
    MCCORKLE, S
    ONOPRIENKO, D
    ONUCHIN, A
    OREN, Y
    PANIN, V
    PARSONS, JA
    RADEKA, V
    ROGERS, L
    RAHM, D
    RESCIA, S
    RUTHERFOORD, J
    SEMAN, M
    SMITH, M
    SONDERICKER, J
    STEINER, R
    STEPHANI, D
    STERN, E
    STUMER, I
    TAKAI, H
    THEMANN, H
    TIKHONOV, Y
    WILLIS, WJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 344 (02): : 363 - 377
  • [10] PERFORMANCE OF A LIQUID ARGON ELECTROMAGNETIC CALORIMETER WITH AN ACCORDION GEOMETRY
    AUBERT, B
    BAZAN, A
    CAVANNA, F
    COLAS, J
    LEFLOUR, T
    VIALLE, JP
    GORDON, HA
    POLYCHRONAKOS, V
    RADEKA, V
    RAHM, D
    STEPHANI, D
    BAISIN, L
    BERSET, JC
    FABJAN, CW
    FOURNIER, D
    GILDEMEISTER, O
    JENNI, P
    LEFEBVRE, M
    MARIN, CP
    NESSI, M
    NESSITEDALDI, F
    PEPE, M
    POLESELLO, G
    RICHTER, W
    SIGRIST, A
    WILLIS, WJ
    CAMIN, DV
    COSTA, G
    GIANOTTI, F
    MANDELLI, L
    PESSINA, G
    ICONOMIDOUFAYARD, L
    MERKEL, B
    PETROFF, P
    REPELLIN, JP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 309 (03): : 438 - 449