Experimental and numerical investigations of the energy efficiency of conventional air conditioning systems in cooling mode and comfort assurance in office buildings

被引:16
|
作者
Sarbu, Ioan [1 ]
Adam, Marius [1 ]
机构
[1] Polytech Univ Timisoara, Dept Bldg Serv Engn, Timisoara 300233, Romania
关键词
VAC system; Air-water mist cooled chiller; Energy performance; Optimal control; Minimum electricity consumption function; Thermal comfort; TRNSYS simulation model; RESIDENTIAL VENTILATION; THERMAL COMFORT; TEMPERATURE; CONSUMPTION; CONDENSER; QUALITY;
D O I
10.1016/j.enbuild.2014.09.022
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper provides a comparative study of the energy efficiency of a conventional ventilating and air conditioning (VAC) system with three configurations. This system was used to cool an experimental room in an office building in more control scenarios realised by adopting different cooled water temperatures and chiller cooling systems. In this purpose, an air-water mist cooled system for an air-cooled chiller is proposed. Depending on the components, the analysed VAC system has the following configurations: (1) air handling unit (AHU) and fan-coil units (FCUs); (2) air handling unit (AHU); and (3) heat recovery unit (HRU) and fan-coil units (FCUs). The electricity consumption weight of the equipment of each VAC system, the total energy consumption and the influence of control parameters on this consumption are analysed. The results of the experiments indicate that the optimal efficiency VAC system in office buildings includes an AHU and FCUs with an air-water mist cooled chiller and a cooled water temperature of 8 degrees C. For this system, a mathematical model is developed to minimise the electricity consumption by optimal control, where the consumption depends only on non-controlled parameters (solar radiation intensity and outdoor air temperature). This model is verified with actual measurements to confirm its accuracy, and a good agreement between the prediction and measurement is achieved. Additionally, the assessment of thermal comfort in the experimental office is performed based on the PMV-PPD model using the ASHRAE Thermal Comfort programme. The obtained results demonstrate that the AHU&FCUs system assures an increase in thermal comfort. Finally, a TRNSYS simulation model of energy consumption and PMV-PPD indices for the AHU&FCUs system is developed and experimentally validated. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:45 / 58
页数:14
相关论文
共 44 条
  • [1] Impact of zoning heating and air conditioning control systems in users comfort and energy efficiency in residential buildings
    Hernandez, Francisco Fernandez
    Suarez, Jose Miguel Pena
    Cantalejo, Juan Antonio Bandera
    Muriano, Mari Carmen Gonzalez
    ENERGY CONVERSION AND MANAGEMENT, 2022, 267
  • [2] Energy and comfort performance of occupant-centric air conditioning strategy in office buildings with personal comfort devices
    Jingsi Zhang
    Xiang Zhou
    Song Lei
    Maohui Luo
    Building Simulation, 2022, 15 : 899 - 911
  • [3] Energy and comfort performance of occupant-centric air conditioning strategy in office buildings with personal comfort devices
    Zhang, Jingsi
    Zhou, Xiang
    Lei, Song
    Luo, Maohui
    BUILDING SIMULATION, 2022, 15 (05) : 899 - 911
  • [4] ENERGY EFFICIENCY OF BUILDINGS AND AIR CONDITIONING SYSTEMS - A COMPARATIVE STUDY.
    Donnelly, E.W.
    Hands, D.J.
    Australian refrigeration, Air conditioning and heating, 1987, 41 (01): : 22 - 24
  • [5] Working object of air conditioning systems and its effects on comfort and energy efficiency
    Yang, Changzhi
    Ye, Guodong
    Nuantong Kongtiao/HV & AC, 2002, 32 (03):
  • [6] Energy efficiency and thermal comfort characteristics of convection-radiation combined cooling system in office buildings
    Liu, Dong
    Liu, Na
    Li, Guanyu
    Wu, Xiaozhou
    Wang, Jun
    Tian, Yabin
    Zhang, Qing
    Hu, Anjie
    Wen, Jialan
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2024, 38 (05) : 2649 - 2660
  • [7] Experimental and numerical investigations on stratified air distribution systems with special configuration: Thermal comfort and energy saving
    Cheng, Yuanda
    Niu, Jianlei
    Liu, Xiaoping
    Gao, Naiping
    ENERGY AND BUILDINGS, 2013, 64 : 154 - 161
  • [8] Numerical simulation of cooling energy consumption in connection with thermostat operation mode and comfort requirements for the Athens buildings
    Tzivanidis, C.
    Antonopoulos, K. A.
    Gioti, F.
    APPLIED ENERGY, 2011, 88 (08) : 2871 - 2884
  • [9] Experimental performance analysis and modelling of liquid desiccant cooling systems for air conditioning in residential buildings
    Pietruschka, D
    Eicker, U
    Huber, M
    Schumacher, J
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (01): : 110 - 124
  • [10] Numerical comparison between energy and comfort performances of radiant heating and cooling systems versus air systems
    Fabrizio, Enrico
    Corgnati, Stefano P.
    Causone, Francesco
    Filippi, Marco
    HVAC&R RESEARCH, 2012, 18 (04): : 692 - 708