Surface electromyographic activity of five residual limb muscles recorded during isometric contraction in transfemoral amputees with osseointegrated prostheses

被引:13
|
作者
Pantall, Annette [1 ]
Durham, Sally [3 ]
Ewins, David [2 ,3 ]
机构
[1] Georgia Inst Technol, Ctr Human Movement Studies, Sch Appl Physiol, Atlanta, GA 30332 USA
[2] Univ Surrey, Ctr Biomed Engn, Guildford GU2 5XH, Surrey, England
[3] Queen Marys Hosp, Douglas Bader Rehabil Ctr, Roehampton, England
关键词
Transfemoral amputation; Osseointegration; Electromyography; Transected muscle; Prosthesis; MOTOR UNIT RECRUITMENT; SPECTRAL PROPERTIES; HIP MUSCLES; FIBER TYPE; EMG; AMPUTATION; GAIT; REHABILITATION; WALKING; VARIABILITY;
D O I
10.1016/j.clinbiomech.2011.03.008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Femoral osseointegrated implants represent a new development in amputee rehabilitation, eliminating socket pressure discomfort, improving hip range of movement and facilitating prosthetic limb attachment. A clinical aspect that has not previously been reported on is the function of muscles in the residuum with implications concerning energy expenditure, hip-hiking and viability of the electrogram as a myoprocessor. Typically, amputees fitted with osseointegrated fixation have shorter residuums and weaker attachment of cleaved muscles. Function of muscle can be assessed by surface electromyography through changes in amplitude and median frequency of the signal. Methods: Five male transfemoral amputees with osseointegrated fixations participated together with a control group comprised of ten adult males. Electrodes recorded surface electromyographic activity of five residual limb muscles or left lower limb muscles of control subjects. Isometric contractions were performed against resistance. The increase in mean rectified amplitude from resting to maximally contracting was calculated and median frequencies estimated. Findings: The amputees were unable to maintain a maximum voluntary contraction of constant amplitude. Amplitude increase was lowest for rectus femoris and adductor magnus. The median frequency of adductor magnus was significantly greater (P=0.02) for the amputees than intact subjects and there was a significant difference (P<0.01) between gluteus maximus and adductor magnus for amputee subjects. Interpretation: High electromyographic amplitude variability suggests that using residuum muscles singly as a myoprocessor might be challenging. Adductor magnus displayed a different sEMG profile compared to intact subjects indicating decreased function and neuromuscular changes. Further work into optimal muscle anchorage is required to ensure maximal mechanical performance. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:760 / 765
页数:6
相关论文
共 3 条
  • [1] Gender Effects in Surface Electromyographic Activity of the Biceps Brachii Muscle during Prolonged Isometric Contraction
    Ahamed, Nizam Uddin
    bin Md Yusof, Zulkifli
    Alqahtani, Mahdi
    Altwijri, Omar
    Rahman, S. A. M. Matiur
    Sundaraj, Kenneth
    COMPLEX ADAPTIVE SYSTEMS, 2015, 2015, 61 : 448 - 453
  • [2] Computation and Study of the Low-Frequency oscillation of Surface Electromyogram recorded in biceps during isometric upper limb contraction
    Tan, Audrey
    Kumar, Dinesh K.
    Arjunan, Sridhar P.
    Jayadeva
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 2128 - 2131
  • [3] The effect of three levels of foot orthotic wedging on the surface electromyographic activity of selected lower limb muscles during gait
    Murley, George S.
    Bird, Adam R.