Anterior Border of the Tibia as a Landmark for Extramedullary Alignment Guide in Total Knee Arthroplasty for Varus Knees

被引:40
|
作者
Fukagawa, Shingo [1 ]
Matsuda, Shuichi [1 ]
Mitsuyasu, Hiroaki [1 ]
Miura, Hiromasa [1 ]
Okazaki, Ken [1 ]
Tashiro, Yasutaka [1 ,2 ]
Iwamoto, Yukihide [1 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Orthopaed Surg, Higashi Ku, Fukuoka 8128582, Japan
[2] Kyushu Univ Hosp, Dept Adv Med & Innovat Technol, Higashi Ku, Fukuoka 8128582, Japan
关键词
total knee arthroplasty; extramedullary alignment guide; mechanical axis; anterior border of the tibia; knee; NAVIGATION SYSTEM; SLOPE; REPLACEMENT; PROSTHESES; JAPANESE; AXIS;
D O I
10.1002/jor.21335
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A disadvantage to using extramedullary alignment guides of the tibia for total knee arthroplasty (TKA) is difficulty in correctly identifying the ankle center. The anterior border of the tibia is easily palpable, as it is not covered by muscles and its shape is convex anteriorly. We hypothesized that appropriate points exist along the anterior border that can be used as landmarks for extramedullary guides. Prior to TKA, computed tomographic images of the entire tibia were obtained from 101 osteoarthritic knees with varus deformities. The relationship between the lines connecting two points on the anterior border and the mechanical axis was evaluated using 3D imaging software. The mean angles between each of 10 determined axes and the mechanical axis varied from 3.2 degrees varus to 2.1 degrees valgus in the coronal plane. In the sagittal plane, all axes referencing the anterior border of the tibia showed anterior inclination to the mechanical axis The line connecting the medial one-third of the patellar tendon attachment and the distal one-fourth of the anterior border, however, was highly consistent and parallel to the mechanical axis in the coronal plane. This axis can be effectively used as a landmark for extramedullary guides during TKA. (C) 2011 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 29:919-924, 2011
引用
收藏
页码:919 / 924
页数:6
相关论文
共 50 条
  • [1] Anterior tibial border as a landmark for extramedullary alignment guides for total knee arthroplasty in valgus knees
    Kawahara, Shinya
    Fukagawa, Shingo
    Murakami, Koji
    Iwamoto, Yukihide
    Banks, ScottA
    Matsuda, Shuichi
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2015, 33 (12) : 1897 - 1899
  • [2] The accuracy of the extramedullary and intramedullary femoral alignment system in total knee arthroplasty for varus osteoarthritic knee
    Woon-hwa Jung
    Chung-woo Chun
    Ji-hoon Lee
    Jae-hun Ha
    Jae-Heon Jeong
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 629 - 635
  • [3] The accuracy of the extramedullary and intramedullary femoral alignment system in total knee arthroplasty for varus osteoarthritic knee
    Jung, Woon-hwa
    Chun, Chung-woo
    Lee, Ji-hoon
    Ha, Jae-hun
    Jeong, Jae-Heon
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (03) : 629 - 635
  • [4] The Adjustment of the Rotational Alignment of the Distal End of the Extramedullary Guide to the Anteroposterior Axis of the Proximal Tibia in Total Knee Arthroplasty
    Mizu-uchi, Hideki
    Kido, Hidehiko
    Chikama, Tomonao
    Kamo, Kenta
    Kido, Satoshi
    Nakashima, Yasuharu
    JOURNAL OF KNEE SURGERY, 2022, 35 (12) : 1273 - 1279
  • [5] Accuracy of Proximal Tibial Bone Cut Using Anterior Border of Tibia as Bony Landmark in Total Knee Arthroplasty
    Nishikawa, Kazutaka
    Mizu-uchi, Hideki
    Okazaki, Ken
    Matsuda, Shuichi
    Tashiro, Yasutaka
    Iwamoto, Yukihide
    JOURNAL OF ARTHROPLASTY, 2015, 30 (12): : 2121 - 2124
  • [6] Extramedullary Guide Alignment Is not Affected by Obesity in Primary Total Knee Arthroplasty
    Compton, Jocelyn
    Owens, Jessell
    Otero, Jesse
    Noiseux, Nicolas
    Brown, Timothy
    JOURNAL OF KNEE SURGERY, 2021, 34 (10) : 1076 - 1079
  • [7] Accuracy of the second metatarsal as a landmark for the extramedullary tibial cutting guide in total knee arthroplasty
    Tsukeoka, Tadashi
    Tsuneizumi, Yoshikazu
    Lee, Tae Hyun
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (12) : 2969 - 2974
  • [8] Accuracy of the second metatarsal as a landmark for the extramedullary tibial cutting guide in total knee arthroplasty
    Tadashi Tsukeoka
    Yoshikazu Tsuneizumi
    Tae Hyun Lee
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 2969 - 2974
  • [9] Varus deformity in the proximal tibia and immediate postoperative varus alignment result in varus progression in limb alignment in the long term after total knee arthroplasty
    Yuichi Kuroda
    Koji Takayama
    Shinya Hayashi
    Shingo Hashimoto
    Takehiko Matsushita
    Takahiro Niikura
    Ryosuke Kuroda
    Tomoyuki Matsumoto
    Knee Surgery, Sports Traumatology, Arthroscopy, 2020, 28 : 3287 - 3293
  • [10] Varus deformity in the proximal tibia and immediate postoperative varus alignment result in varus progression in limb alignment in the long term after total knee arthroplasty
    Kuroda, Yuichi
    Takayama, Koji
    Hayashi, Shinya
    Hashimoto, Shingo
    Matsushita, Takehiko
    Niikura, Takahiro
    Kuroda, Ryosuke
    Matsumoto, Tomoyuki
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (10) : 3287 - 3293